P-385-63 Range Safety Pamphlet Download
Page 72 of 251
Figure 6–4. Surface danger zone, Area F, for firing multi- role anti-armor antipersonnel weapon system c. SDZ requirements for the M136 AT4 are in table 6–4 and figures 6–5 and 6–6. Table 6–4 M136 AT4 surface danger zone criteria, in meters Area F Type Distance X Minimum range to target Area A Area B Danger area 1 Caution area 2 84mm 3 HEAT M136 2,100 50 3 227 488 5 95 9mm Trainer, M939 1,600 N/A N/A N/A N/A N/A Legend for Table 6-4: N/A=not applicable Notes: 1 Danger area occupation could result in fatalities or serious casualties including severe burns, eye damage, or permanent hearing loss. The hazards are base plate fragments, debris, fireball, high noise levels, and overpressure. 2 Caution area is an extension of the primary danger area. Occupation of this area could also result in severe casualties due to back blast, debris, high noise levels, and possible base plate fragments. Primary danger area and caution area are conditions that may not be modified. 3 Increased dud rates may occur when firing HE (M136) at impact angles of 10 degrees or less. 60 DA PAM 385–63 • 16 April 2014