Laparoscopic Electrosurgical Electrode
Item Name Code (INC) 48752
Additional Information for Laparoscopic Electrosurgical Electrode
Laparoscopic electrosurgical electrodes are medical instruments used in laparoscopic surgery. Laparoscopic surgery is a minimally invasive surgical technique that uses small incisions and specialized instruments to perform procedures inside the abdomen or pelvis.
Electrosurgical electrodes are used in laparoscopic surgery to deliver electrical energy to tissues, allowing for cutting, coagulation, and tissue sealing. These electrodes are designed to be used with electrosurgical generators, which provide the electrical energy.
Laparoscopic electrosurgical electrodes come in various shapes and sizes, depending on the specific surgical procedure and the desired tissue effect. Some common types of electrodes include:
1. Monopolar electrodes: These electrodes have a single active electrode that delivers electrical energy to the tissue, while a return electrode is placed elsewhere on the patient's body to complete the electrical circuit.
2. Bipolar electrodes: These electrodes have two active electrodes that are used to deliver electrical energy directly to the tissue. Bipolar electrodes do not require a separate return electrode, as the electrical circuit is completed within the instrument itself.
3. Dissecting electrodes: These electrodes are used for cutting and dissecting tissues during laparoscopic surgery. They typically have a sharp tip or blade for precise tissue dissection.
4. Coagulating electrodes: These electrodes are used for coagulating or sealing blood vessels and tissues to minimize bleeding during surgery. They often have a broader surface area to distribute the electrical energy and achieve a more uniform coagulation effect.
Laparoscopic electrosurgical electrodes are typically made of stainless steel or other conductive materials that can withstand the high temperatures generated during electrosurgery. They are designed to be reusable or disposable, depending on the manufacturer's specifications.
It is important to note that the use of laparoscopic electrosurgical electrodes requires specialized training and expertise to ensure safe and effective use during surgery.
Related Item Names for INC 48752 Laparoscopic Electrosurgical Electrode
NATO Stock Numbers with Item Name 48752 Laparoscopic Electrosurgical Electrode Page 1 of 1
- F93K183
- RNCC: 5 | RNVC: 1 | DAC: 4
- E2780-28
- RNCC: 3 | RNVC: 2 | DAC: 4
- E2781-28
- RNCC: 3 | RNVC: 9 | DAC: 4
- E2782-28
- RNCC: 3 | RNVC: 2 | DAC: 4
- 6515NCM127092
- RNCC: 5 | RNVC: 1 | DAC: 4
- 6515NCM127091
- RNCC: 5 | RNVC: 1 | DAC: 4
- 6515NCM031700
- RNCC: 5 | RNVC: 1 | DAC: 4
- 300-125
- RNCC: 3 | RNVC: 2 | DAC: 4
- 6515NCM031701
- RNCC: 5 | RNVC: 1 | DAC: 4
- 300-159
- RNCC: 3 | RNVC: 2 | DAC: 4
- 98-2154
- RNCC: 5 | RNVC: 1 | DAC: 4
- 93-11-2-99 FS
- RNCC: 5 | RNVC: 1 | DAC: 4
- 0008
- RNCC: 3 | RNVC: 2 | DAC: 4
- 0028
- RNCC: 3 | RNVC: 2 | DAC: 4
- 0028M
- RNCC: 3 | RNVC: 2 | DAC: 4
- 0016M
- RNCC: 3 | RNVC: 2 | DAC: 4
- 0020
- RNCC: 3 | RNVC: 2 | DAC: 4
- 0013M
- RNCC: 3 | RNVC: 2 | DAC: 4
- 0021
- RNCC: 3 | RNVC: 2 | DAC: 4
- TD8B
- RNCC: 3 | RNVC: 2 | DAC: 6
- 0015
- RNCC: 3 | RNVC: 2 | DAC: 4
- 0012
- RNCC: 3 | RNVC: 2 | DAC: 4
- 0013
- RNCC: 3 | RNVC: 2 | DAC: 4
- 0009
- RNCC: 3 | RNVC: 2 | DAC: 4
- ETRIO335H
- RNCC: 5 | RNVC: 2 | DAC: 4
- NO PRIMARY REF 99-191-1421
- RNCC: 3 | RNVC: 2 | DAC: 9
- NSEAL535RE
- RNCC: 5 | RNVC: 2 | DAC: 4
- ETRIO335E
- RNCC: 5 | RNVC: 2 | DAC: 4
- NO PRIMARY REF 99-581-0888
- RNCC: 3 | RNVC: 2 | DAC: 9
- NSEAL525RE
- RNCC: 5 | RNVC: 2 | DAC: 4