Premium Information is available for this item - Upgrade for $1 a day
6685-00-798-6904
Capillary Tube And Bulb Indicating Thermometer
6685007986904 007986904 58DFFM 2-NAE-94901-AGA-001 3333-14 XF58-71 33H5
A thermometer which employs a confined substance, whose measurable physical properties or one of them varies with a change in temperatrue and this energy transmitted into mechanical movement to indicate the temperature. For indoor/outdoor application, see THERMOMETER, SELF-INDICATING, LIQUID IN GLASS. View more Capillary Tube And Bulb Indicating Thermometer
May 2023
10


Marketplace 6685-00-798-6904
Request a Quotation from participating marketplace vendors
Related Documents 6685-00-798-6904 5+ Documents (More...)
(Identification) 1/2 NSN 6685-00-798-6904 (Identification) 2/2 - - 1.
Updated Every Day 6685-00-798-6904 RQST NE Updated Every Day 6685-00-798-6904 RQST Updated Every Day
6685007986904 007986904,58DFFM Documents ( More... ) https//www.nsnlookup.com https//www.nsnlookup.com
AssyUOMTechnical DocumentQuantative ExpressionDefense Logistics Agency (DS)IZDiscontinued-Use 6685-00-798-6904
6685007986904 007986904,58DFFM Account Upgrade 6685-00-798-6904Capillary Tube And Bulb Indicating
Thermometer6685007986904 007986904 58DFFM 6685008145684 008145684,58DFFM Account Upgrade 6685-00-814
6685007986904 007986904,58DFFM 6685-00-798-6904Capillary Tube And Bulb Indicating Thermometer6685007986904
007986904 58DFFM 2-NAE-94901 INDICATING,CAPILLARY TUBE AND BULB 1 EA NS Request Quotation Subscribe
58DFFM 6685008145683008145683 6685008145684 008145684,58DFFM Account Upgrade 6685-00-814-5684Capillary
https//www.nsnlookup.com /fsg-66/fsc-6685/us 6685-00-798-6904 6685007986904 007986904,58DFFM Account
Restrictions 6685-00-798-6904
6685-00-798-6904 is a Capillary Tube And Bulb Indicating Thermometer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 6685-00-798-6904
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6685-00-798-6904
- US Air Force (FXGG)
- Effective Date:
- 1 Feb 2005
- Former MOE Rule:
- FXCX
- Spain (YB01)
- Effective Date:
- 1 Jun 1999
- Republic of Korea (ZH01)
- Effective Date:
- 1 Apr 1991
- Greece (ZU01)
- Effective Date:
- 1 Apr 2008
- Turkey (ZW01)
- Effective Date:
- 1 Nov 2005
Approved Sources 6685-00-798-6904
- Part Number
- Manufacturer
- Status
- 2-NAE-94901-AGA-001
- Manufacturer
- 38508 - Desco Corp Marsh Bellofram Div (Replaced)
- Original Design
- Original Design
- 2-NAE-94901-AGA-001
- 01170 - Bellofram Corporation (Active)
- Secondary Buy
- Secondary Buy
- 3333-14
- 91515 - Arnolt Corp (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- XF58-71
- 38508 - Desco Corp Marsh Bellofram Div (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- 58DFFM
- 38508 - Desco Corp Marsh Bellofram Div (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- 33H5
- 91515 - Arnolt Corp (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 58DFFM
- 01170 - Bellofram Corporation (Active)
- Advisory Reference
- Advisory Reference
Datasheet 6685-00-798-6904
- Characteristic
- Specifications
- FIIG
- Specifications
- A27600
- Scale Type [ATEQ]
- Concentric Dial
- Material [MATT]
- Steel Meter Case
- Material [MATT]
- Copper Bulb
- Style Designator [STYL]
- Bulb W/O Socket
- Bulb Tip Length [BKCG]
- 7.125 Inches Nominal
- Case Diameter [ABKJ]
- 4.750 Inches Nominal
- Dial Diameter [ASSP]
- 3.500 Inches Nominal
- Pointer/Pen Type And Quantity [CSYJ]
- 1 Indicating Single
- Indicator Connection Method [BLQF]
- Flexible Tube
- Bulb Type [BKCW]
- Plain Rigid
- Bulb Quantity [BKCT]
- 1
- Bulb Style [CRSK]
- Plain Bulb W/Bendable Extension
- Active Portion Length [BKCY]
- 7.125 Inches Nominal
- Active Portion Diameter [BKCZ]
- 0.625 Inches Nominal
- Bulb Overall Length [CSYH]
- 7.937 Inches Nominal
- Extension Neck Length [BKCH]
- 0.812 Inches Nominal
- Bulb Connection Type [BKCX]
- Union
- Flexible Tube Length [BLQG]
- 72.000 Inches Nominal
- Actuating Medium [BKCM]
- Liquid
- Mounting Facility Type And Quantity [AXHR]
- 3 Hole
- Unthreaded Mounting Hole Diameter [AEBV]
- 0.218 Inches Nominal
- Case Type [BHMC]
- Dustproof
- Features Provided [CBBL]
- Zero Adjustment
- Scale Accuracy Rating [BKCN]
- 2.5 Pct
- Scale Smallest Increment [AWAG]
- 5.0 Deg Fahrenheit
Weapon Systems (WSDC) 6685-00-798-6904
DLA Procurement Analysis 6685-00-798-6904
Management Data 6685-00-798-6904
Similar Supply Items to 6685-00-798-6904


















Freight Information 6685-00-798-6904
6685-00-798-6904 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 058360. A Sub NMFC of Z. It has a NMFC Description of THERMOMETERS,O/THAN CLINICAL. 6685-00-798-6904 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 33220 which rates the freight between FCL and LCL. 6685-00-798-6904 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 652 for ocean manifesting and military sealift. 6685-00-798-6904 is not classified as a special type of cargo when transported by water. 6685-00-798-6904 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 6685-00-798-6904
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- Electrical Instrument
- Over 10lb
- Less than 85G
- Special Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- Physical Protection
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- --
- --
- --
- --
- PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
- Delicate instrument
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- --
Contracting Technical Data File (CTDF) 6685-00-798-6904 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- K
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- N
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: