6645-00-880-4893
Time Totalizing Meter
6645008804893 008804893 MIL-DTL-3971 2437026-1 635ES100AB0008A 635ES100AA0008A M3971/2-6 C2A 10N-G3 10N-G3-N A12599 235503 338-120V 56017-2-02 59S6 9100 M595S120VAC60CPS A47788 M595-120VAC60CPS 56049 56821 60S5 EZ21H 178375 KH12507P1 31EHXXW 7712495P2
An instrument that automatically measured, and cumulatively registers the total operating or idle time of any circuit, machine or system, to which it is connected. See METER, FREQUENCY AND TIME TOTALIZING, ELECTRICAL. View more Time Totalizing Meter
November 2023
211
Marketplace 6645-00-880-4893
Request a Quotation from participating marketplace vendors
Related Documents 6645-00-880-4893 5+ Documents (More...)
MIL-M-3971 465-1051-1 M3971/2-6 MS16971-2 911800077 31EX 10N-G3-H An instrument that automatically measured
Time Totalizing Meter 6645008804893 008804893 day Upgrade your Account Upgrade 6645-00-880-4893Time
| RNVC: 2 | DAC: 4 7 Nov 1995 6130-17-111-2637 https//www.nsnlookup.com /fsg-66/fsc-6645/us 6645-00-880-4893
Time Totalizing Meter 6645008804893 008804893 N A12599 235503 338-120V 56017-2-02 59S6 9100 M595S120VAC60CPS
MIL-M-3971 METER,TIME TOTALIZING 3 EA NS Request Quotation 235503 METER,TIME TOTALIZING 2 EA NS Request
9100 METER,TIME TOTALIZING 360 EA NS Request Quotation Subscribe to View Vendor Details... 56048 METER
TOTALIZING 57 EA NS Request Quotation 235503 METER,TIME TOTALIZING 2 EA NS Request Quotation MIL-M-3971
Subscribe to View Vendor Details... 394583 METER,TIME TOTALIZING 36 EA NS Request Quotation 56048 METER
to View Vendor Details... 9100 METER,TIME TOTALIZING 57 EA NS Request Quotation MIL-M-3971 METER,TIME
9100 METER,TIME TOTALIZING 360 EA NS Request Quotation Subscribe to View Vendor Details... 56048 METER
Restrictions 6645-00-880-4893
6645-00-880-4893 is a Time Totalizing Meter that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Import and Export 6645-00-880-4893
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6645-00-880-4893
- Brazil (YA01)
- Effective Date:
- 1 Jan 2002
- Spain (YB01)
- Effective Date:
- 1 Apr 1991
- Australia (ZA01)
- Effective Date:
- 1 Apr 1991
- Canada (ZC01)
- Effective Date:
- 1 Apr 1991
- New Zealand (ZE01)
- Effective Date:
- 1 Apr 1991
- Germany (ZG01)
- Effective Date:
- 1 Apr 1991
- Republic of Korea (ZH01)
- Effective Date:
- 1 Apr 1991
- United Kingdom (ZK01)
- Effective Date:
- 1 Sep 2000
- Portugal (ZP01)
- Effective Date:
- 1 Apr 1991
- Italy (ZR01)
- Effective Date:
- 1 Jul 1997
- Norway (ZT01)
- Effective Date:
- 1 Apr 1991
- Greece (ZU01)
- Effective Date:
- 1 Apr 1991
- Turkey (ZW01)
- Effective Date:
- 1 Nov 1998
Approved Sources 6645-00-880-4893
- Part Number
- Manufacturer
- Status
- M3971/2-6
- Manufacturer
- 81349 - Military Specifications (Active)
- Definitive Standard
- Definitive Standard
- MIL-DTL-3971
- 81349 - Military Specifications (Active)
- Incomplete Standard
- Incomplete Standard
- C2A
- 30703 - Essex Products Group, Inc. (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 10N-G3
- 07446 - Sangamo Weston Inc (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 10N-G3-N
- 07446 - Sangamo Weston Inc (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- A12599
- 82227 - Vdo Control Systems Inc (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 235503
- 36378 - Raytheon Technical Services Company (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- 338-120V
- 82386 - Jaidinger Manufacturing Co Inc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 56017-2-02
- 16476 - Maxima Technologies & Systems Llc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 59S6
- 14907 - Cramer Co Division Of Chestnut Group (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 9100
- 57737 - Herman H Sticht Company, Inc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- M595S120VAC60CPS
- 16476 - Maxima Technologies & Systems Llc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- A47788
- 07860 - Bogue Electric Manufacturing Co (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- M595-120VAC60CPS
- 16476 - Maxima Technologies & Systems Llc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 56049
- 26992 - Hamilton Watch Co Inc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 56821
- 14907 - Cramer Co Division Of Chestnut Group (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 60S5
- 14907 - Cramer Co Division Of Chestnut Group (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- EZ21H
- 14907 - Cramer Co Division Of Chestnut Group (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 178375
- 65092 - Solartron Electronics Inc (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- KH12507P1
- 82227 - Vdo Control Systems Inc (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 31EHXXW
- 31356 - Lee Co The J B T Div (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 7712495P2
- 03538 - Lockheed Martin Corporation (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- TETG16C5
- 21810 - Challenger Electrical Equipment Corp (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 940250-1
- 82577 - Raytheon Company (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 394583
- 36378 - Raytheon Technical Services Company (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- D16963PT51
- 15309 - Jewell Instruments, Llc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 683052
- 82577 - Raytheon Company (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- MS16971-2
- 96906 - Military Standards (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 56049
- 16476 - Maxima Technologies & Systems Llc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 56048
- 26992 - Hamilton Watch Co Inc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- M595S120VAC60CPS
- 26992 - Hamilton Watch Co Inc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 56017-2-02
- 26992 - Hamilton Watch Co Inc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 56048
- 16476 - Maxima Technologies & Systems Llc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- M595-120VAC60CPS
- 26992 - Hamilton Watch Co Inc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 4533864-1
- 28528 - Itt Industries Inc (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- B12549
- 82227 - Vdo Control Systems Inc (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 105018
- 45413 - Teledyne Electronics (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- M1932
- 74400 - Hobbs Corp (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- MI1932
- 74400 - Hobbs Corp (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- MIL-M-3971
- 81349 - Military Specifications (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 16NG3
- 07446 - Sangamo Weston Inc (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 2437026-1
- 11243 - Cosmodyne, Llc (Active)
- Advisory Reference
- Advisory Reference
- 635ES100AB0008A
- 14907 - Cramer Co Division Of Chestnut Group (Obsolete)
- Advisory Reference
- Advisory Reference
- 635ES100AA0008A
- 14907 - Cramer Co Division Of Chestnut Group (Obsolete)
- Advisory Reference
- Advisory Reference
Datasheet 6645-00-880-4893
- Characteristic
- Specifications
- FIIG
- Specifications
- T134-R
- Electrical Movement Type [BHLR]
- Synchronous Motor
- Background Color [BHLQ]
- Black Background On Hr Wheels,White Background On Tenths Wheel
- Body Depth [ARBR]
- 3.000 Inches Maximum
- Body Diameter [ABPM]
- 2.625 Inches Maximum
- Case Material [ADTV]
- Any Acceptable
- Current Type [ACDC]
- Ac
- Hermetic Protection [AQCS]
- Not Provided
- Maximum Measurement [BHLN]
- 99999.90
- Measurement Unit [ANSX]
- Hours
- Mounting Configuration [ALGC]
- Three 0.150 In. Dia Mtg Holes On 1.580 In. Radius Spaced 120 Deg Apart
- Mounting Flange Diameter [APTE]
- 3.500 Inches Maximum
- Mounting Method [AXGY]
- Flush
- Mounting Type [AAXX]
- Panel
- Movement Type [AQEC]
- Electrical
- Nondefinitive Spec/Std Data [ZZZT]
- B Grade And 2 Type
- Operating Frequency [APTT]
- 60.0 Hertz Nominal
- Indicator Type [AMKD]
- Drum Register
- Marking Color [BHLP]
- White Numerals For Hours,Black Numerals For Tenths
- Reset Feature [BHCH]
- Not Provided
- Smallest Increment Indicated [AXEA]
- 0.10
- Unit Type [APQB]
- Mounted
- Voltage Rating [AMSE]
- 120.0 Volts Nominal
- Terminal Quantity [AARA]
- 2
- Terminal Type [AARB]
- Solder Lug Or Stud
DLA Procurement Analysis 6645-00-880-4893
Management Data 6645-00-880-4893
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- May 2008
- Defense Logistics Agency (DS)
- EA
- Subscribe
- 1
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Defense Logistics Agency (DS)
- I
- Z
- Discontinued-Use 6645-01-057-7987
- Z
NATO Stock Numbers Related to 6645-00-880-4893
Freight Information 6645-00-880-4893
6645-00-880-4893 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 136760. A Sub NMFC of X. It has a NMFC Description of METERS ELEC WATT-HOUR USED. 6645-00-880-4893 is rated as class 70 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 68830 which rates the freight between FCL and LCL. 6645-00-880-4893 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 657 for ocean manifesting and military sealift. 6645-00-880-4893 is not classified as a special type of cargo when transported by water. 6645-00-880-4893 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 6645-00-880-4893
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- Electrical Instrument
- Over 10lb
- Less than 85G
- Special Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- A-A-1249, Paper, Tissue
- A-A-1051, Paperboard Cushioning
- --
- PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
- No special marking
- A-A-1249, Paper, Tissue
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- --
Contracting Technical Data File (CTDF) 6645-00-880-4893 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: