Premium Information is available for this item - Upgrade for $1 a day
6640-01-050-9859
Constant Temperature Bath
6640010509859 010509859 MW-1110A-1
An item consisting of a reservoir and a temperature control device. It utilizes a liquid media to heat or control samples used in laboratory testing of organic coatings, asphalt and petroleum products. It can also be used to verify the accuracy of temperature sensors or instruments. It may include such components and accessories as water jackets, heaters, cooling coils, circulating pumps, bombs, and racks. Excludes WATER BATH, ELECTRIC and WATER BATH, NONELECTRIC. View more Constant Temperature Bath
January 2023
5

Marketplace 6640-01-050-9859
Request a Quotation from participating marketplace vendors
Related Documents 6640-01-050-9859 1+ Documents (More...)
6640-01-050-9859 1+ Documents ( More... ) https//www.nsnlookup.com /fsg-66/fsc-6640/us 6640-01-050-9859
Constant Temperature Bath 6640010509859 RQST NE Updated Every Day 6640-01-050-9859 RQST Updated Every
Restrictions 6640-01-050-9859
6640-01-050-9859 is a Constant Temperature Bath that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
Import and Export 6640-01-050-9859
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6640-01-050-9859
- NASA (G510)
- Effective Date:
- 1 Apr 1991
- Canada (ZC01)
- Effective Date:
- 1 Apr 1991
Approved Sources 6640-01-050-9859
- Part Number
- Manufacturer
- Status
- MW-1110A-1
- Manufacturer
- 89715 - Spx Corporation (Active)
- Primary Buy
- Primary Buy
Datasheet 6640-01-050-9859
- Characteristic
- Specifications
- FIIG
- Specifications
- T269-J
- Accessory Components And Quantity [AKYD]
- Thermometer,1; 6 Ft. Cord,1; 3-Wire Plug,1
- Accuracy Range [BNDS]
- -0.2/+0.2 Deg Celsius
- Agitator [BNDQ]
- Included
- Capacity Rating [BBLT]
- 3.500 Gallons Nominal
- Constant Water Level Attachment [BNDH]
- Not Included
- Cooling Coils For Below Room Temp Use [BNDW]
- Not Included
- Current Type [ACDC]
- Ac
- Frequency Rating [ACZB]
- 50.0 Hertz Minimum And 60.0 Hertz Maximum
- Heating Element Current Type [BBJZ]
- Ac
- Heating Element Quantity [BKGK]
- 2
- Heating Element Frequency Rating [BNDP]
- 50.0 Hertz Minimum And 60.0 Hertz Maximum
- Heating Element Phase [BBKB]
- Single
- Heating Element Type [BDXJ]
- Electric Immersion
- Heating Element Voltage Rating [BKGR]
- 120.0 Volts Nominal
- Heating Element Wattage In Watts [BBTG]
- 800.0
- Operating Temp Range [AFGA]
- +25.0/+100.0 Deg Celsius
- Inner Surface Color [BNDK]
- Any Acceptable
- Inside Depth [AFEF]
- 7.500 Inches Nominal
- Inside Width [ADJT]
- 7.500 Inches Nominal
- Insulated Feature [AHGR]
- Included
- Inside Length [ADJU]
- 12.000 Inches Nominal
- Low Water Cutoff [BNDJ]
- Not Included
- Reservoir Material [BNDF]
- Steel, Stainless
- Reservoir Removability [BNDG]
- Nonremovable
- Shape [SHPE]
- Rectangular
- Phase [FAAZ]
- Single
- Pilot Light [BNDY]
- Included
- Voltage Rating [AMSE]
- 120.0 Volts Nominal
- Wattage Rating [BDWW]
- 800.0 Watts
- Temp Regulating Settings [BNDT]
- Automatic Temp Control Permits Selection Of Any 2 Temperatures,But All Temperatures Within Range May Also Be Used W/O Changing The 2 Settings
- Test Tube Rack [BNDM]
- Not Included
- Thermometer Opening [BNDX]
- Not Provided
- Thermoregulator [BNDR]
- Included