6640-01-030-8929
Laboratory Distilling Apparatus
6640010308929 010308929 MOD III
Excludes petroleum distillation test apparatus. View more Laboratory Distilling Apparatus
![]()
November 2023
7

Marketplace 6640-01-030-8929
Request a Quotation from participating marketplace vendors
Related Documents 6640-01-030-8929 5+ Documents (More...)
030-8929 Apparatus 010308929 https//www.nsnlookup.com -66/fsc-6640/us 6640-01-030-8929 Laboratory Distilling
Apparatus 010308929 fsc-6640/us 6640-01-030-8929 Laboratory Distilling Apparatus 010308929 www.nsnlookup.com
www.nsnlookup.com /fsg-70/fsc-7010/it 7010-15-230-2102 P.C.P/Iii/450 32Mb 7010152302102152302102 MOD. III
Laboratory Distilling Apparatus 010308929 7010-15-230-2102 https//www.nsnlookup.com /fsg-66/fsc
/fsc-7010/it 7010-15-172-5254 Scanner Hewlett Pac 7010151725254151725254 SCANNER HEWLETT PACKARD MOD. III
www.nsnlookup.com /fsg-70/fsc-7010/it 7010-15-172-5254 https//www.nsnlookup.com /fsg-66/fsc-6640/us 6640-01-030-8929
Laboratory Distilling Apparatus 010308929 www.nsnlookup.com /fsg-66/fsc-6640/us 6640-01-030-8929
Laboratory Distilling Apparatus 010308929 7010-15-230-2102 https//www.nsnlookup.com https https
Restrictions 6640-01-030-8929
6640-01-030-8929 is a Laboratory Distilling Apparatus that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
End Users 6640-01-030-8929
- NASA (G510)
- Effective Date:
- 1 Apr 1991
Approved Sources 6640-01-030-8929
- Part Number
- Manufacturer
- Status
- MOD III
- Manufacturer
- 55607 - Gilmont Roger Instruments Inc (Obsolete)
- Original Design
- Original Design
Datasheet 6640-01-030-8929
- Characteristic
- Specifications
- Distilling Unit Quantity [BQLX]
- Specifications
- 1
- Assembly Form [AFPM]
- Knocked-Down
- Bleeder Device [BQWY]
- Not Included
- Carrying Case [AFJU]
- Not Provided
- Condenser Type [AWLP]
- Vertical
- Current Type [ACDC]
- Ac
- Feed Type [AQDD]
- Continuous
- Frequency Rating [ACZB]
- 60.0 Hertz Nominal
- Heating Method [BDWT]
- Electrical
- Material [MATT]
- Glass And Plastic Polytetrafluoroethylene
- Load Capacity [BQLQ]
- 1.8 Liters Per Hour
- Low Water Automatic Heater Shut-Off [BQWX]
- Included
- Power Rating [ANPT]
- 1.2 Kilowatts Nominal
- Phase [FAAZ]
- Single
- Voltage Rating [AMSE]
- 120.0 Volts Nominal