Premium Information is available for this item - Upgrade for $1 a day
6630-01-088-4142
Electrophoresis Apparatus
6630010884142 010884142 500 165-0520
INC: 77777
November 2023
5

Marketplace 6630-01-088-4142
Request a Quotation from participating marketplace vendors
Related Documents 6630-01-088-4142 5+ Documents (More...)
6630-01-088-4142 Electrophoresis Apparatus 6630010884142,500 1005-01-165-0520 1+ https//www.nsnlookup.com
5905-00-165- 0520 RQST Updated Every Day 5905-00-165-0520 RQST NE Related Documents 5905-00-165-0520
4210-15-165-0520 3+ Documents ( More... ) https//www.nsnlookup.com /fsg-42/fsc-4210/it 4210-15-165-0520
RQST NE Updated Every Day 4210-15-165-0520 RQST Updated Every Day 4210-15-165-0520 RQST NE Related Documents
Request a Quotation from participating marketplace vendors Request Related Documents 5305-66-165-0520
/fsg-66/fsc-6630/us 6630-01-088-4142 Electrophoresis Apparatus 6630010884142,500 1005-01-165-0520 1+
RQST NE Updated Every Day 5905-00-165- 0520 RQST Updated Every Day 5905-00-165-0520 RQST NE Related
Documents 5905-00-165-0520 2+ Documents https//www.nsnlookup.com /fsg-66/fsc-6630/us 6630-01-088-4142
BUY NE FedMall Updated Every Day 1005-01-165-0520 RQST NE Updated Every Day 1005-01-165-0520 RQST Updated
Every Day 1005-01-165-0520 RQST NE Related Documents 1005-01-165-0520 1+ Documents ( More... ) https
Restrictions 6630-01-088-4142
6630-01-088-4142 is a Electrophoresis Apparatus that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
End Users 6630-01-088-4142
- NASA (G510)
- Effective Date:
- 1 Apr 1991
Approved Sources 6630-01-088-4142
- Part Number
- Manufacturer
- Status
- 165-0520
- Manufacturer
- 10987 - Bio-Rad Laboratories Clinical Div (Active)
- Primary Buy
- Primary Buy
- 500
- 10987 - Bio-Rad Laboratories Clinical Div (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
Datasheet 6630-01-088-4142
- Characteristic
- Specifications
- General Characteristics Item Description [TEXT]
- Specifications
- Electric Cell,0-500 V Output,110 V,60 Hz,23 Cm W,20 Cm H,37 Cm D,8 Kg Weight,Dual Output Jacks,Dual Range Meters For Expanded Low Level Readings At Full Scale Accurary,Crossover Design Switches,Multi-Turn Current Control,Polarity Reversing Switches Eliminate Cable Reversals