Premium Information is available for this item - Upgrade for $1 a day
6625-01-386-7091
Frequency Standard
6625013867091 013867091 808-100-18 MRT-HT
An item that can generate a fundamental frequency with a high degree of accuracy. Harmonics of this fundamental are then used as a reference point for checking throughout the radio spectrum. The standard may be stable crystal oscillator, noncrystal oscillator, tuning fork, atomic beam, molecular beam, gas cell, quantum mechanical resonator, or the like. View more Frequency Standard
![]()
January 2023
7

Marketplace 6625-01-386-7091
Request a Quotation from participating marketplace vendors
Related Documents 6625-01-386-7091 4+ Documents (More...)
MRT-HT FREQUENCY STANDARD 2 EA NS Request Quotation Updated Every Day 6625-01-386-7091 RQST NE Updated
Every Day 6625-01-386-7091 RQST Updated Every Day 6625-01-386-7091 RQST NE Related Documents 6625-01
Frequency Standard 6625013867091 013867091 6625-01-386-7091 RQST NE Related Documents 6625-01 https
Frequency Standard 6625013867091 013867091 386-7091 RQST NE Related Documents 6625-01 https https
Frequency Standard 6625013867091 013867091 7091 RQST NE Related Documents 6625-01 https https https
Restrictions 6625-01-386-7091
IUID Required
6625-01-386-7091 is a Frequency Standard that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. The DCMO has forced the Demilization requirements for this item as the ICP has not collaborated. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 6625-01-386-7091
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6625-01-386-7091
- US Air Force (FGG4)
- Effective Date:
- 1 Sep 2000
- Former MOE Rule:
- FEE4
- Greece (ZU01)
- Effective Date:
- 1 May 2008
Approved Sources 6625-01-386-7091
- Part Number
- Manufacturer
- Status
- 808-100-18
- Manufacturer
- 55761 - Efratom Time & Frequency Products, (Active)
- Primary Buy
- Primary Buy
- MRT-HT
- 55761 - Efratom Time & Frequency Products, (Active)
- Secondary Buy
- Secondary Buy
Datasheet 6625-01-386-7091
- Characteristic
- Specifications
- FIIG
- Specifications
- T263-R
- Ac Voltage Rating [ACYN]
- 115.0 Volts Minimum And 220.0 Volts Maximum
- Dc Voltage Rating [ACYR]
- 23.0 Volts Minimum And 32.0 Volts Maximum
- Furnished Items And Quantity [AKYN]
- Ac Line Cord,1;Mating Connector For J9 Dc Input,1;Mating Connector For J11 Remote Monitor,1;Fuse 1A,250V,3Ag Slo-Blo Type,1;Fuse 3A,250V,3Ag Slo-Blo Type,1
- Frequency Rating [ACZB]
- 47.0 Hertz Minimum And 400.0 Hertz Maximum
- Mounting Method [AXGY]
- Rack
- Unit Type [APQB]
- Standard
- Recording Device Accommodation [BHZL]
- Not Provided
- Overall Depth [ABFY]
- 14.330 Inches Nominal
- Overall Height [ABKW]
- 5.250 Inches Nominal
- Overall Width [ABMK]
- 19.000 Inches Nominal
- Special Features [FEAT]
- Provides Sinusoidal Signals At Frequencies Of 10, 5, 1, And 0.1 Mhz;Four Output Connectors On The Front Paneland Four Output Connectors On The Rearpanel Which Can Be Used Simultaneously;Output Levels Are 1.0 Vrms With A 50 Ohm Resistive Load;Contains 2 Rechargeable Gel-Type Batteries To Provide For6 Hours Of Backup Operation;Weight Is 40 Lbs.;Meter & Meter Select Switch Control Voltage,Rubidium Lamp,Dc Supply,Charge Current;Application Data: 6625011545040;Mrt-Ht Is Mfgr Model No;Operating Temp: 1E-10 From O Deg C To +50 Deg C Ambient;Altitude: 1E-13/Mbar (Sea Level To 40,000 Ft.
Management Data 6625-01-386-7091
Similar Supply Items to 6625-01-386-7091


















Freight Information 6625-01-386-7091
6625-01-386-7091 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061700. A Sub NMFC of X. It has a NMFC Description of ELEC APPLIANCES/INSTRUMENTS NOI. 6625-01-386-7091 is rated as class 100 when transported by Less-Than Truckload (LTL) freight. 6625-01-386-7091 is rated as class 77.5 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 34580 which rates the freight between FCL and LCL. 6625-01-386-7091 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 738 for ocean manifesting and military sealift. 6625-01-386-7091 is classified as an Electrostatic Sensitive Device (ESD) when transported by water. 6625-01-386-7091 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.