Premium Information is available for this item - Upgrade for $1 a day
6625-01-336-3372
Multimeter
6625013363372 013363372 77-4BN 77 III/BN SPMIG 03632 73-3 FLUKE-77-3/BN SEE AEL 7-67005A504 456720000301 6625PL0644903
An instrument which is arranged to measure two or more different electrical quantities (such as volts, amps, and ohms) by means of associated circuits and switches. The value is usually expressed on a single calibrated dial or digital readout display. For items which are connected into a circuit and used chiefly to visually monitor an operation, see METER, MULTIPLE SCALE. See also COUNTER, ELECTRONIC, DIGITAL READOUT. Excludes BRIDGE (as modified). View more Multimeter
November 2023
35
Marketplace 6625-01-336-3372
Request a Quotation from participating marketplace vendors
77-4BN RQST NE
77 III/BN RQST NE
SPMIG 03632 RQST NE
FLUKE-77-3/BN RQST NE
Related Documents 6625-01-336-3372 5+ Documents (More...)
Multimeter 6625013363372 013363372,77-4BN -01-336-3372 Multimeter 73-3RNCC: 5 | RNVC: 2 | https
5406Department of the Air Force (DF)FRRefer To S013363372S013363372US Marine Corps (DM)MZDiscontinued-Use 6625-01-336-3372
Multimeter 6625013363372 013363372,77-4BN Marine Corps (DM)MZDiscontinued-Use 6625-01-336-3372
AssyUOMTechnical DocumentQuantative ExpressionDepartment of the Navy (DN)NZDiscontinued-Use 6625-01-336-3372
-2 73-3-R A device having the dual function of providing restraint for, and facilitating the removal
NumberManufacturerStatus2618701-2 80064 - Naval Ship Systems Command (Active) Primary Buy RNCC 3 RNVC 2 DAC 1 73-3
Restrictions 6625-01-336-3372
6625-01-336-3372 is a Multimeter that does not have a nuclear hardened feature, but does have another critical feature or features such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item has been determined to be hazardous and information is contained in the Hazardous Materials Information Resource System (HMIRS). This item does not contain a precious metal.
Import and Export 6625-01-336-3372
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6625-01-336-3372
- US Army (A411)
- Effective Date:
- 1 Mar 2007
- Supplementary Receivers:
- AM
- US Coast Guard (C020)
- Effective Date:
- 1 Apr 1991
- US Air Force (FGHD)
- Effective Date:
- 1 Sep 2000
- Former MOE Rule:
- FEHD
- Supplementary Receivers:
- TT
- US Marine Corps (MN71)
- Effective Date:
- 1 Apr 1991
- US Navy (N1H5)
- Effective Date:
- 1 Apr 1991
- Supplementary Collaborators:
- HSKEJNHX
- Supplementary Receivers:
- GG
- Hungary (WH01)
- Effective Date:
- 1 Jul 2011
- Poland (WP01)
- Effective Date:
- 1 Oct 2004
- Brazil (YA01)
- Effective Date:
- 1 Dec 2001
- Spain (YB01)
- Effective Date:
- 1 Feb 1994
- Malaysia (YW01)
- Effective Date:
- 1 May 2002
- Australia (ZA01)
- Effective Date:
- 1 Apr 1991
- Canada (ZC01)
- Effective Date:
- 1 Nov 2008
- France (ZF01)
- Effective Date:
- 1 Mar 2000
- Germany (ZG01)
- Effective Date:
- 1 Apr 1991
- Republic of Korea (ZH01)
- Effective Date:
- 1 Apr 1991
- Italy (ZR01)
- Effective Date:
- 1 Jul 1997
- Norway (ZT01)
- Effective Date:
- 1 Jun 2011
- Greece (ZU01)
- Effective Date:
- 1 May 2008
- Turkey (ZW01)
- Effective Date:
- 1 Nov 1998
Approved Sources 6625-01-336-3372
- Part Number
- Manufacturer
- Status
- 77-4BN
- Manufacturer
- 4U744 - Fluke Electronics Corp (Active)
- Primary Buy
- Primary Buy
- FLUKE-77-3/BN
- 89536 - Fluke Corp (Active)
- Original Design
- Original Design
- 77 III/BN
- 89536 - Fluke Corp (Active)
- Secondary Buy
- Secondary Buy
- SPMIG 03632
- 89536 - Fluke Corp (Active)
- Secondary Buy
- Secondary Buy
- 73-3
- 3TZV5 - Techni-Tool Llc (Active)
- Secondary Buy
- Secondary Buy
- SEE AEL 7-67005A504
- 12004 - Naval Sea Systems Command Logistics (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 77-4BN
- 89536 - Fluke Corp (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 456720000301
- 0000V - Ncb Hungary (Honvedsegi Egyseges (Active)
- NATO Reference
- NATO Reference
- 6625PL0644903
- 9009H - Jednolity Indeks Materialowy - (Active)
- NATO Reference
- NATO Reference
Datasheet 6625-01-336-3372
- Characteristic
- Specifications
- FIIG
- Specifications
- A310A0
- Circuit Attachment Method And Quantity [CTTD]
- 1 Probe, Direct Contact And 2 Wire Lead
- Circuit Current For Which Designed [AACT]
- Ac And Dc
- Criticality Code Justification [CRTL]
- Feat
- Display Digit Quantity [BFQP]
- 3-1/2
- Display Type [BFQN]
- Liquid Crystal
- Features Provided [CBBL]
- Warning Feature
- Fsc Application Data [ZZZV]
- Gpete Program
- Measurement Range [BHMW]
- +0.0/+3.2 Volts, Ac Single Indicator 6Th Range
- Measurement Range [BHMW]
- +0.0/+3.2 Volts, Dc Single Indicator 2Nd Range
- Measurement Range [BHMW]
- +0.0/+32.0 Milliamps Single Indicator 10Th Range
- Measurement Range [BHMW]
- +0.0/+32.0 Volts, Ac Single Indicator 7Th Range
- Measurement Range [BHMW]
- +0.0/+32.0 Volts, Dc Single Indicator 3Rd Range
- Measurement Range [BHMW]
- +0.0/+320.0 Volts, Ac Single Indicator 8Th Range
- Measurement Range [BHMW]
- +0.0/+320.0 Volts, Dc Single Indicator 4Th Range
- Measurement Range [BHMW]
- +0.0/+320.0 Milliamps Single Indicator 11Th Range
- Measurement Range [BHMW]
- +0.0/+320.0 Millivolts, Dc Single Indicator 1St Range
- Measurement Range [BHMW]
- +0.0/+750.0 Volts, Ac Single Indicator 9Th Range
- Measurement Range [BHMW]
- +0.0/+10.0 Amperes Single Indicator 12Th Range
- Measurement Range [BHMW]
- +0.0/+1000.0 Volts, Dc Single Indicator 5Th Range
- Installation Design [AMQY]
- Hand Held
- Indicator Type [AMKD]
- Digital Display
- Power Source [AWZJ]
- Internal
- Scale Selection Method [BLSB]
- Switch
- Overall Depth [ABFY]
- 1.120 Inches Nominal
- Overall Length [ABHP]
- 6.550 Inches Nominal
- Overall Width [ABMK]
- 2.950 Inches Nominal
- Special Features [FEAT]
- Items Are Being Coded As Critical To Insure Source Inspection Will Be Performed At The Point Of Manufacture, Prior To Material Receipt By The Us Navy Or Other Dod Components. These Items Are Piece Parts Or End Items In Support Of Vital Military Hardware Necessary To Sustain The Successful Mission Of The Ships, Submarines, And Shore Stations Of The Us Navy. Critical Features Including, But Not Limited To, Dimensions, Tolerances/Clearances, Electronic Characteristics, And Metallurgical Properties Will Bespecified For Government Q Ar (Quality Assurance Representatives) To Insure The Highest Possible Degree Of Quality And Reliability Of These Parts Being Delivered Under Navicp Contracts
- Style Designator [STYL]
- Hand-Held
DLA Procurement Analysis 6625-01-336-3372
- Last Stock Position:
- 1 In Stock
- DLA Administrative Lead Time:
- Subscribe
- DLA Production Lead Time:
- Subscribe
Management Data 6625-01-336-3372
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Oct 2022
- Department of the Navy (DN)
- EA
- Subscribe
- 1
- EA
- Jan 2022
- Department of the Army (DA)
- EA
- Subscribe
- 1
- EA
- Nov 2021
- Department of the Navy (DN)
- EA
- Subscribe
- 1
- EA
- Oct 2021
- Department of the Army (DA)
- EA
- Subscribe
- 1
- EA
- Oct 2020
- Department of the Army (DA)
- EA
- Subscribe
- 1
- EA
- Oct 2019
- Department of the Air Force (DF)
- EA
- Subscribe
- 1
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Army (DA)
- A
- V
- Discontinued Without Replacement
- V
- Department of the Air Force (DF)
- F
- R
- Refer To Dsn 932-5406
- DSN 932-5406
- R
- Department of the Air Force (DF)
- F
- R
- Refer To Gidep Alert
- GIDEP ALERT
- R
- Department of the Air Force (DF)
- F
- R
- Refer To Kc-S-95-01
- KC-S-95-01
- R
- Department of the Air Force (DF)
- F
- R
- Refer To S012139354
- S012139354
- R
- US Marine Corps (DM)
- M
- 0
- Reversal Of Phrase Code Z 6625-01-213-9354
- 0
- US Marine Corps (DM)
- M
- 5
- Reversal Of Phrase Code L 6625-01-131-8586
- 5
- US Marine Corps (DM)
- M
- 5
- Reversal Of Phrase Code L 6625-01-266-3494
- 5
Army
- Materiel Category and Inventory Manager:
- M
- Ammunition weapons, and tracked combat vehicles weapons, special weapons, chemical and fire control materiel
- Appropriation and Budget Activity:
- 2
- Stock Fund Secondary Items
- Management Inventory Segment:
- 1
- Repairable Items(Exclusive of Insurance and Provisioning Items)
This code will be used to identify serviceable or unserviceable items of a durable nature, which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance.
- Weapons System / End Item / Homogeneous Group:
- 00
- DLA/GSA Material
DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
- Accounting Requirements:
- X
- Expendable item.An item of Army property coded with an ARC of X in the AMDF. Expendable items require no formal accountability after issue from a stock record account.Commercial and fabricated items similar to items coded X in the AMDF are considered expendable items.
Air Force
- Fund:
- SF
- Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point
- Budget:
- 9
- 57X4921.070 - General Support DIV - Air Force decentralized managed expense items (ERRC XB3, XF3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors
- Aggregation Code:
- TG
- AF SICA RESIDUAL MMAC-WR-ALC
- Price Validation Code:
- N
- The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
The price has not been analyzed or reviewed for accuracy.
ZOP or Standard price challenges are permissible but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of āLā or āFā, then it must be evaluated locally where purchased or fabricated.
- Expendability
Recoverability
Repairability: - N
- Expendable. Condemn at User. Stock Fund (except Munitions).
Navy
- Cognizance:
- 1H
- Consumable material assigned to NAVICP MECH for inventory management
Naval Inventory Control Point, Mechanicsburg
- Special Material ID:
- TE
- General Purpose Electronic Test Equipment
- Issue, Repair, Requisition Restriction Code:
- 00
- No Restriction
- Special Material Content:
- 9
- Non-Hazardous or Non-Sensitive Item
Marine Corps
- Stores Account:
- 1
- Stock Fund Account Item
- Combat Essentiality:
- 0
- Non-combat Essential End Item
- Echelon Management:
- 46
- Material Identification:
- C
- Type 2 (as required items)
- Operational Test:
- 3
- Calibration Required
- Physical Category:
- 1
- Bin
NATO Stock Numbers Related to 6625-01-336-3372
Freight Information 6625-01-336-3372
6625-01-336-3372 has freight characteristics managed by the Food and Drug Administration (FDA).It has a National Motor Freight Classification (NMFC) of 136740. A Sub NMFC of Z. It has a NMFC Description of METERS ELEC/PARTS. 6625-01-336-3372 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. 6625-01-336-3372 is rated as a variable freight class when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 68820 which rates the freight between FCL and LCL. 6625-01-336-3372 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 657 for ocean manifesting and military sealift. 6625-01-336-3372 is not classified as a special type of cargo when transported by water. 6625-01-336-3372 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 6625-01-336-3372
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- Packaging Data does not meet current MIL-STD-2073-1E
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- Over 10lb
- Less than 85G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- No Requirement
- PPP-C-795, Cellular Plastic Film Cushioning; or A-A-3129, Open Cell Plastic Cushioning; or PPP-C-1797, Polypropylene Foam Cushioning; or A-A-59136, Polyethylene Foam Cushioning
- --
- --
- No special marking
- No Requirement
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- --
- No Requirement