Premium Information is available for this item - Upgrade for $1 a day
6625-01-280-2906
Voltage Calibrator
6625012802906 012802906 5440B/AF
An item specifically designed to determine by comparison accurate input and output voltages of major electronic components. Excludes VOLTMETER and VOLTMETER, ELECTRONIC. View more Voltage Calibrator
January 2023
11
Marketplace 6625-01-280-2906
Request a Quotation from participating marketplace vendors
Related Documents 6625-01-280-2906 5+ Documents (More...)
6625002381250 002381250 062-5167 6625-21-867-3945 6625-01-280-2906 6625/us 6625-00-249-5519 Voltage
6625-01-609-2806 867-1370 6625-25-142-1962 6625002381250 002381250 062-5167 6625-21-867-3945 6625-01-280-2906
Voltage Calibrator 6625012802906 012802906 for $1 a day Upgrade your Account Upgrade 6625-01-280
-2906Voltage Calibrator6625012802906 012802906 5440B Request a Quotation from participating marketplace
Voltage Calibrator 6625012802906 012802906 6625-00-062-5167 6625-21-867-3945 6625-01-280-2906 https
Stock Numbers Related to 6625-01-262-4851 6625-21-886-9928 6625-00-062-5167 6625-21-867-3945 6625-01-280-2906
Voltage Calibrator 6625012802906 012802906 6625-00-062-5167 6625-21-867-3945 6625-01-280-2906 https
Stock Numbers Related to 6625-01-065-0536 6625-21-886-9928 6625-00-062-5167 6625-21-867-3945 6625-01-280-2906
Voltage Calibrator 6625012802906 012802906 002495519 062-5167 6625-21-867-3945 6625-01-280-2906
Stock Numbers Related to 6625-00-469-5459 6625-21-886-9928 6625-00-062-5167 6625-21-867-3945 6625-01-280-2906
Restrictions 6625-01-280-2906
IUID Required
6625-01-280-2906 is a Voltage Calibrator that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. The DCMO has forced the Demilization requirements for this item as the ICP has not collaborated. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 6625-01-280-2906
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6625-01-280-2906
- US Air Force (FGG4)
- Effective Date:
- 1 Sep 2000
- Former MOE Rule:
- FEE4
- Singapore (YJ01)
- Effective Date:
- 1 Apr 1991
- Philippines (ZM01)
- Effective Date:
- 1 Feb 2015
Approved Sources 6625-01-280-2906
- Part Number
- Manufacturer
- Status
- 5440B/AF
- Manufacturer
- 89536 - Fluke Corp (Active)
- Primary Buy
- Primary Buy
Datasheet 6625-01-280-2906
- Characteristic
- Specifications
- FIIG
- Specifications
- T263-B
- Ac Voltage Rating [ACYN]
- 100.0 Volts Minimum And 240.0 Volts Maximum
- Calibration Range Quantity [BDHT]
- 4
- Frequency Rating [ACZB]
- 50.0 Hertz Minimum And 60.0 Hertz Maximum
- Mounting Method [AXGY]
- Rack
- Instrument Calibration Range [BDHS]
- 0.000/11.000/22.000/275.000/1100.000
- Overall Height [ABKW]
- 9.400 Inches Nominal
- Overall Length [ABHP]
- 24.000 Inches Nominal
- Overall Width [ABMK]
- 17.000 Inches Nominal
- Special Features [FEAT]
- Vacuum-Fluorescent Displays; Output Current 0-25 Ma; Direct Voltage
- Unpackaged Unit Weight [AWJN]
- 66.400 Pounds
Management Data 6625-01-280-2906
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Sep 2018
- Department of the Air Force (DF)
- EA
- Subscribe
- 1
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Air Force (DF)
- L
- F
- When Exhausted Use 6625-01-226-5448
- F
Air Force
- Budget:
- M
- 57X3080 - Other Base Maintenance and Support Equipment
- Aggregation Code:
- RH
- AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
- Price Validation Code:
- P
- The current standard price is the initial negotiated provisioned price.
This is the price paid by DoD for the item as the result of price negotiation of the Provisioned Item Order (PIO) or other initial negotiated price.
ZOP or Standard Price challenges are permissible but should be supported with adequate justification.
- Expendability
Recoverability
Repairability: - S
- Reparable. Condemn at Depot. AF Equipment Management System (AFEMS).
NATO Stock Numbers Related to 6625-01-280-2906
Freight Information 6625-01-280-2906
6625-01-280-2906 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061700. A Sub NMFC of X. It has a NMFC Description of ELEC APPLIANCES/INSTRUMENTS NOI. 6625-01-280-2906 is rated as class 100 when transported by Less-Than Truckload (LTL) freight. 6625-01-280-2906 is rated as class 77.5 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 34580 which rates the freight between FCL and LCL. 6625-01-280-2906 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 6625-01-280-2906 is not classified as a special type of cargo when transported by water. 6625-01-280-2906 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 6625-01-280-2906
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- 25.0" H x 17.0" W x 9.0" L
- --
- Electrical Instrument
- Over 10lb
- Less than 85G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- 36.5" H x 26.5" W x 19.0" L
- --
- --
- --
- Any Suitable Process
- 36.5" H x 26.5" W x 19.0" L
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- --
- --
- --
- PPP-B-1672, Type III, Telescoping Encapsulated Cushioning in Reusable Box
- No special marking
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- No Requirement