Premium Information is available for this item - Upgrade for $1 a day

6625-01-100-5949

Circuit Board/Power Supply Test Station

6625011005949 011005949 153111

6625-01-100-5949 TEST STATION,CIRCUIT BOARD/POWER SUPPLY 6625011005949 011005949

Managed by United States
NSN Created on 10 Sep 1980
Data Last Changed
January 2023
NATO Update Count
7
NATO Data Quality
6625-01-100-5949 TEST STATION,CIRCUIT BOARD/POWER SUPPLY 6625011005949 011005949 1/1
NSN 6625-01-100-5949 (Generic Image) 1/1

6625-01-100-5949 Stock and Availability Marketplace 6625-01-100-5949

6625-01-100-5949 Related Documents Related Documents 6625-01-100-5949 5+ Documents (More...)

$1 a day Upgrade your Account Upgrade 3110-01-240-1586Annular Ball Bearing3110012401586 012401586 153111
Station your Account Upgrade 6625-01-100-5949Circuit Board/Power Supply Test Station6625011005949 011005949
... 153111 STATION,CIRCUIT BOARD/POWER SUPPLY 1 EA NS Request Quotation Subscribe to View Vendor Details
CAGE 79S9G Prague Shakespeare Company, Z.U. in Praha - Vinohrady, Praha 2, Praha Czech Republic
6625-17-603-2596 6625176032596 176032596 is an instrument which measures the rate of regularly recurring variations in an electric current or voltage and is usually calibrated in hertz (cycles per second or cps). the value may be expressed by means of a pointer and calibrated dial vibrating reed or a digital read out display. for instruments which measure radio frequencies, see calibrator, frequency; and wavementer. excludes: counter electronic digital.
enable JavaScript in your web browser . 5940-99-547-6368Lug Terminal5940995476368 995476368 A11654 153111
Part NumberManufacturerStatusA11654 K0967 - Mbda Uk Ltd (Active) Source Control RNCC 1 RNVC 2 DAC 2 153111
K1636 - Tyco Electronics Uk Ltd (Replaced) Primary Buy RNCC 3 RNVC 2 DAC 2 153111 F0286 - Tyco Electronics

6625-01-100-5949 Demil Restrictions 6625-01-100-5949

DEMIL: A | DEMILI: | CRITICALITY: X | HMIC: P | PMIC: U | EDC: | ADPEC:

6625-01-100-5949 is a Circuit Board/Power Supply Test Station that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.

6625-01-100-5949 HTS and ScheduleB Import and Export 6625-01-100-5949

6625-01-100-5949 End Users End Users 6625-01-100-5949

Republic of Korea (ZH01)
Effective Date:
1 Jun 1996

6625-01-100-5949 Manufacturers Approved Sources 6625-01-100-5949

6625-01-100-5949 Technical Data Datasheet 6625-01-100-5949

Characteristic
Specifications
FIIG
A23900
End Item Identification [AGAV]
5895003409555
General Characteristics Item Description [TEXT]
0C/O 1 Test Fixture Power Supply,1 Digital Multimeter,Plug In,1 Vertical,1 Time Base,1 Oscilloscope,1 Module Level Test Station,1 Cable,2 Power Supply,1 P28v,1 Test Panel;1 Cabinet Instrument;Station Self-Contained/Rqmt 110Vac,60 Hz/External

6625-01-100-5949 Related Items NATO Stock Numbers Related to 6625-01-100-5949

6625-01-100-5949 Freight Data Freight Information 6625-01-100-5949

6625-01-100-5949 has freight characteristics managed by the General Services Administration (GSA).It has a National Motor Freight Classification (NMFC) of 061700. A Sub NMFC of X. It has a NMFC Description of ELEC APPLIANCES/INSTRUMENTS NOI. 6625-01-100-5949 is rated as class 100 when transported by Less-Than Truckload (LTL) freight. 6625-01-100-5949 is rated as class 175 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 34580 which rates the freight between FCL and LCL. 6625-01-100-5949 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 738 for ocean manifesting and military sealift. 6625-01-100-5949 is classified as an Electrostatic Sensitive Device (ESD) when transported by water. 6625-01-100-5949 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

6625-01-100-5949 Packaging Data Packaging Data 6625-01-100-5949

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
--
--

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
--
36.5" H x 26.5" W x 19.0" L
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
--
--
--
PPP-B-1672, Type III, Telescoping Encapsulated Cushioning in Reusable Box
Method 50 reusable container

Intermediate Pack Level

Quantity of Unit Packs
Container
--
No Requirement