6625-01-033-3468

Pulse Generator

6625010333468 010333468 1441

An electronic device which develops a discontinuous electrical potential with an abrupt rate of change of voltage which determines the harmonic content of the pulse train. The duration of a single pulse output is relatively short compared to the time of the recurrence cycle. See also GENERATOR, SINGLE PULSE; and GENERATOR, ELECTRONIC MARKER. View more Pulse Generator

6625-01-033-3468 GENERATOR,PULSE 6625010333468 010333468

Managed by United States
NSN Created on 3 Jan 1977
Data Last Changed
November 2023
NATO Update Count
7
NATO Data Quality
6625-01-033-3468 GENERATOR,PULSE 6625010333468 010333468 1/1
NSN 6625-01-033-3468 (Generic Image) 1/1

6625-01-033-3468 Stock and Availability Marketplace 6625-01-033-3468

6625-01-033-3468 Related Documents Related Documents 6625-01-033-3468 5+ Documents (More...)

Documents 6625-01-034-4680 5+ Documents ( More... ) https//www.nsnlookup.com /fsg-66/fsc-6625/us 6625-01-033-3468
Pulse Generator 6625010333468 010333468,1441 https//www.nsnlookup.com /nato/nato-stock-numbers/
www.nsnlookup.com /nato/nato-stock-numbers/inc Pulse Generator (INC 00411) DAC: 5 25 Jan 1977 6625-01-033-3468
(CAGE Code 24114) DAC: 4 13 Mar 1986 6625-01-033-3468 Pulse Generator 1441RNCC: 3 | RNVC: 2 | DAC: 4
7085 Multi Chan Analyzer 3201RNCC: 3 | RNVC: 2 | DAC: 635RNCC: 3 | RNVC: 2 | DAC: 4 13 Mar 1986 6625-01-033-3468
5 18 Feb 1977 6625-01-034-4680 Pulse Generator 1418-14RNCC: 3 | RNVC: 2 | DAC: 5 25 Jan 1977 6625-01-033-3468

6625-01-033-3468 Demil Restrictions 6625-01-033-3468

DEMIL: A | DEMILI: | CRITICALITY: X | HMIC: P | PMIC: U | EDC: | ADPEC:

6625-01-033-3468 is a Pulse Generator that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.

6625-01-033-3468 End Users End Users 6625-01-033-3468

NASA (G510)
Effective Date:
1 Apr 1991

6625-01-033-3468 Manufacturers Approved Sources 6625-01-033-3468

6625-01-033-3468 Technical Data Datasheet 6625-01-033-3468

Characteristic
Specifications
Basic Shape Style [AGTA]
Rectangular Or Square
Connection Type And Location [BJBP]
Receptacle, Coaxial Front And Receptacle, Coaxial Rear
Control Type [AQZF]
Local
External Dc Operating Voltage In Volts [BKFB]
12.0 Nominal 1St Voltage
External Dc Operating Voltage In Volts [BKFB]
24.0 Nominal 2Nd Voltage
Circuit Construction Type [BHSX]
Solid State
Operating Control Method [ALBM]
Manual
Impedance Rating Per Channel [BHTN]
75.000 Ohms Output Channel
Installation Design [AMQY]
Module
Polarity Per Channel [BHTS]
Positive Input Channel
Polarity Per Channel [BHTS]
Positive Output Channel
Pulse Rise Time Per Channel [BHTQ]
100.000 Nanoseconds Maximum Input Channel
Pulse Rise Time Per Channel [BHTQ]
100.000 Nanoseconds Maximum Output Channel
Signal Voltage Rating Per Channel [BHTK]
1.000 Volts Minimum Input
Signal Voltage Rating Per Channel [BHTK]
10.000 Volts Maximum Input
Signal Voltage Rating Per Channel [BHTK]
8.000 Volts Nominal Output
Overall Width [ABMK]
2.700 Inches Nominal
Special Features [FEAT]
Provides Logic Signal Output When Pulses From 2,3,Or 4 Inputs All Occur Within Period Set By Control; Resolving Time Of Fast Coincidence May Be Varied Over 5-100 Nsec Range By 10-Turn Control