Premium Information is available for this item - Upgrade for $1 a day
6625-00-932-7811
Electrical Frequency Meter
6625009327811 009327811 04758
An instrument which measures the rate of regularly recurring variations in an electric current or voltage and is usually calibrated in Hertz (cycles per second or CPS). The value may be expressed by means of a pointer and calibrated dial vibrating reed or a digital read out display. For instruments which measure radio frequencies, see CALIBRATOR, FREQUENCY; and WAVEMENTER. Excludes: COUNTER ELECTRONIC DIGITAL. View more Electrical Frequency Meter
January 2023
11
Marketplace 6625-00-932-7811
Request a Quotation from participating marketplace vendors
Related Documents 6625-00-932-7811 5+ Documents (More...)
What is CAGE Code 04758?
And Northrup Co located at , Los Angeles CA 90000, United States.Who is CAGE Code 04758?
to reference the physical entity known as Vosschemie Gmbh located at Wellerswalder Weg 24, Oschatz, 04758
CJ834 refers to Vosschemie Gmbh located at Wellerswalder Weg 24, Oschatz, 04758, Germany.Where is CAGE
79707 refers to Family Pak Potato Co Inc located at Nutter St, PO Box 471, Mars Hill ME 04758, United
1GZ40 refers to Duncan Funeral Home Inc located at 8 Main St, Mars Hill ME 04758, United States.Where
4BMR4 refers to Smith Kevin W & Son located at E Ridge Rd, Mars Hill ME 04758-0000, United States.Where
Restrictions 6625-00-932-7811
6625-00-932-7811 is a Electrical Frequency Meter that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
Import and Export 6625-00-932-7811
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6625-00-932-7811
- New Zealand (ZE01)
- Effective Date:
- 1 Apr 1991
- Greece (ZU01)
- Effective Date:
- 1 Apr 1991
- Turkey (ZW01)
- Effective Date:
- 1 Nov 1998
Approved Sources 6625-00-932-7811
- Part Number
- Manufacturer
- Status
- 04758
- Manufacturer
- 97520 - Basler Electric Co (Active)
- Primary Buy
- Primary Buy
Datasheet 6625-00-932-7811
- Characteristic
- Specifications
- FIIG
- Specifications
- A310A0
- Accuracy In Percent [APPN]
- -3.0/+3.0 At Full Scale Single Indicator Single Range
- Circuit Attachment Method And Quantity [CTTD]
- 2 Solder Lug
- Measurement Range [BHMW]
- +375.0/+475.0 Hertz Single Indicator Single Range
- Meter Body Diameter Behind Mounting Flange [APSW]
- 2.672 Inches Nominal
- Meter Depth Behind Mounting Flange [APST]
- 1.430 Inches Nominal
- Mounting Arrangement Style [ANRL]
- Three Hole/Stud Bolt Circle
- Mounting Bolt Circle Diameter [AFFL]
- 3.160 Inches Nominal
- Mounting Facility Type And Quantity [AXHR]
- 3 Unthreaded Hole
- Mounting Hole Diameter [ABTB]
- 0.150 Inches Nominal
- Movement Type [AQEC]
- Vibrating Reed
- Installation Design [AMQY]
- Panel
- Register Quantity [ANQD]
- 1
- Resonant Reed Quantity [APMP]
- 11
- Scale Division Quantity [ABWG]
- 5 Single Indicator Single Range
- Overall Diameter [ADAV]
- 3.500 Inches Nominal
- Overall Length [ABHP]
- 1.805 Inches Nominal
- Style Designator [STYL]
- Round Flush Mtg
NATO Stock Numbers Related to 6625-00-932-7811
Freight Information 6625-00-932-7811
6625-00-932-7811 has freight characteristics managed by the Food and Drug Administration (FDA).It has a National Motor Freight Classification (NMFC) of 136740. A Sub NMFC of Z. It has a NMFC Description of METERS ELEC/PARTS. 6625-00-932-7811 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 68820 which rates the freight between FCL and LCL. 6625-00-932-7811 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 657 for ocean manifesting and military sealift. 6625-00-932-7811 is not classified as a special type of cargo when transported by water. 6625-00-932-7811 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 6625-00-932-7811
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- --
- --
- --
- --
- --
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- No Requirement
- PPP-C-795, Cellular Plastic Film Cushioning; or A-A-3129, Open Cell Plastic Cushioning; or PPP-C-1797, Polypropylene Foam Cushioning; or A-A-59136, Polyethylene Foam Cushioning
- --
- PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
- No special marking
- No Requirement
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- Any Suitable Fiber Box