Premium Information is available for this item - Upgrade for $1 a day
6625-00-892-5263
Radio Frequency Power Test Set
6625008925263 008925263 ANUSM193 431B 431B01
A test set primarily designed for use in making examinations of the power output of radio frequency oscillators and radio and radar transmitters. See also TEST SET, ELECTRICAL POWER; and WATTMETER. View more Radio Frequency Power Test Set
January 2023
40

Marketplace 6625-00-892-5263
Request a Quotation from participating marketplace vendors
Related Documents 6625-00-892-5263 5+ Documents (More...)
Day 6625-00-892-5263 RQST Updated Every Day 6625-00-892-5263 RQST NE Related Documents 6625-00-892-5263
of the power output Day 6625-00-892-5263 RQST Updated Every Day 6625-00-892-5263 RQST NE Related Documents
TEST SET,RADIO FREQUENCY POWER 1 EA NS Request Quotation 431B TEST SET,RADIO FREQUENCY POWER 1 EA NS
431-B TEST SET,RADIO FREQUENCY POWER 1 EA NS Request Quotation Subscribe to View Vendor Details... 431B
Scraper 3805010883653010883653 on 20 Jan 1967 Data https//www.nsnlookup.com /fsg-66/fsc-6625/us 6625-00-892-5263
Radio Frequency Power Test Set 6625008925263 Quotation Subscribe to View Vendor Details... 431B
-243-7541 Scaler Timer 6645002437541 002437541,431B 3874Wrapping Paper.7530231123874231123874 34-X-431B
enable JavaScript in your web browser . 6680-37-557-1329Meter Assy6680375571329 375571329AA62C-55-431B
Vendor Details... 260B SCRAPER,TRACTOR 48 EA NS Request Quotation Subscribe to View Vendor Details... 431B
JavaScript in your web browser . 9905-15-059-3631Instruction Plate9905150593631 150593631 TAL2700-431B
Restrictions 6625-00-892-5263
IUID Required
6625-00-892-5263 is a Radio Frequency Power Test Set that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. The DCMO has forced the Demilization requirements for this item as the ICP has not collaborated. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 6625-00-892-5263
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6625-00-892-5263
- US Air Force (FGG4)
- Effective Date:
- 1 Sep 2000
- Former MOE Rule:
- FEE4
- US Navy (NSGS)
- Effective Date:
- 1 Sep 2000
- Former MOE Rule:
- NSES
- Supplementary Collaborators:
- KE
- Spain (YB01)
- Effective Date:
- 1 Jun 2003
- New Zealand (ZE01)
- Effective Date:
- 1 Apr 1991
- France (ZF01)
- Effective Date:
- 1 Mar 2000
- Germany (ZG01)
- Effective Date:
- 1 Apr 1991
- Republic of Korea (ZH01)
- Effective Date:
- 1 Apr 1991
- United Kingdom (ZK01)
- Effective Date:
- 1 Feb 1994
- Italy (ZR01)
- Effective Date:
- 1 Jul 1997
- Denmark (ZS01)
- Effective Date:
- 1 Apr 1991
- Norway (ZT01)
- Effective Date:
- 1 Apr 1991
- Greece (ZU01)
- Effective Date:
- 1 Apr 1991
- Turkey (ZW01)
- Effective Date:
- 1 Nov 1998
Approved Sources 6625-00-892-5263
- Part Number
- Manufacturer
- Status
- 431B
- Manufacturer
- 1LQK8 - Keysight Technologies, Inc. (Replaced)
- Original Design
- Original Design
- ANUSM193
- 80058 - Joint Electronics Type Designation (Active)
- Secondary Buy
- Secondary Buy
- 431B
- 28480 - Hewlett-Packard Company (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 431B01
- 1LQK8 - Keysight Technologies, Inc. (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- 431B01
- 28480 - Hewlett-Packard Company (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 6625-00-892-5263
- Characteristic
- Specifications
- FIIG
- Specifications
- T228-F
- Accessory Component Quantity [AFHS]
- 1 And 1 And 1
- Ac Voltage Rating [ACYN]
- 115.0 Volts Nominal And 230.0 Volts Nominal
- Accessory Controlling Agency [AKVY]
- Jetds And Jetds And Jetds
- Accessory Identifying Number [AKVZ]
- Ts-2082/U Type No. And Cx-9795/U Type No. And Cx-9673/U Type No.
- Dc Voltage Rating [ACYR]
- 27.0 Volts Nominal
- Furnished Items [AFJH]
- Test Set,Radio Frequency;Cable Assembly,Special Purpose,Electrical;Cable Assembly,Power,Electrical
- Frequency Rating [ACZB]
- 1.0 Kilohertz Minimum And 50000.0 Kilohertz Maximum
- Height [HGTH]
- 6.531 Inches Nominal
- Measurement Unit [ANSX]
- Average Power
- Input Frequency Range [AREN]
- +0.050 To 1.000 Gigahertz
- Inclosure Feature [ANPZ]
- Single Item W/Housing
- Input Impedance Rating [AMND]
- 100.0 Ohms Nominal And 200.0 Ohms Nominal
- Internal Battery Accommodation [ALSF]
- Included
- Joint Electronics Type Designation System Item Type Number [AKWB]
- Type No.An/Usm-193
- Joint Electronics Type Designation System Item Name [AKWA]
- Test Set,Rf Power
- Length [ABRY]
- 12.500 Inches Nominal
- Material And Location [ANNQ]
- Aluminum Housing
- Radio Frequency Input Power Rating [AREP]
- 10.0 Microwatts Minimum And 10000.0 Microwatts Maximum
- Scale Direction And Range [ABWD]
- 0 To 10 Clockwise
- Scale Unit Of Measure Inscription [ABWC]
- Milliwatts
- Phase [FAAZ]
- Single And Single
- Width [ABGL]
- 7.781 Inches Nominal
- Surface Treatment [SFTT]
- Paint
Management Data 6625-00-892-5263
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Oct 2018
- Department of the Air Force (DF)
- EA
- Subscribe
- 1
- EA
- Jan 2011
- Department of the Navy (DN)
- EA
- Subscribe
- 1
- EA
- May 1991
- US Marine Corps (DM)
- EA
- Subscribe
- 1
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Air Force (DF)
- L
- R
- Refer To P012364776
- P012364776
- R
Air Force
- Budget:
- M
- 57X3080 - Other Base Maintenance and Support Equipment
- Aggregation Code:
- RH
- AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
- Price Validation Code:
- N
- The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
The price has not been analyzed or reviewed for accuracy.
ZOP or Standard price challenges are permissible but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of āLā or āFā, then it must be evaluated locally where purchased or fabricated.
- Expendability
Recoverability
Repairability: - S
- Reparable. Condemn at Depot. AF Equipment Management System (AFEMS).
Navy
- Cognizance:
- 3H
- Special Material ID:
- TE
- General Purpose Electronic Test Equipment
- Special Material Content:
- 9
- Non-Hazardous or Non-Sensitive Item
Marine Corps
- Stores Account:
- 1
- Stock Fund Account Item
- Combat Essentiality:
- 2
- Non-Critical Repair Part
- Echelon Management:
- 41
- Operational Test:
- No Special Procedures
NATO Stock Numbers Related to 6625-00-892-5263
Freight Information 6625-00-892-5263
6625-00-892-5263 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061700. A Sub NMFC of Z. It has a NMFC Description of ELEC APPLIANCES/INSTRUMENTS NOI. 6625-00-892-5263 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. 6625-00-892-5263 is rated as class 77.5 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 34580 which rates the freight between FCL and LCL. 6625-00-892-5263 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 738 for ocean manifesting and military sealift. 6625-00-892-5263 is classified as an Electrostatic Sensitive Device (ESD) when transported by water. 6625-00-892-5263 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 6625-00-892-5263
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- Over 10lb
- Less than 85G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- 16.5" H x 10.5" W x 10.5" L
- --
- --
- --
- Any Suitable Process
- 16.5" H x 10.5" W x 10.5" L
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- A-A-3174, Plastic Sheet, Polyolefin, 2mil
- PPP-C-795, Cellular Plastic Film Cushioning; or A-A-3129, Open Cell Plastic Cushioning; or PPP-C-1797, Polypropylene Foam Cushioning; or A-A-59136, Polyethylene Foam Cushioning
- --
- ASTM-D5118, Type CF, Class Weather-Resistant, Corrugated Fiberboard Box
- Method 50 reusable container
- A-A-3174, Plastic Sheet, Polyolefin, 2mil
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- --
- No Requirement