Premium Information is available for this item - Upgrade for $1 a day

6625-00-775-0505

Voltmeter

6625007750505 007750505 1801752

An instrument which measures electrical potential and is calibrated in volts or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. View more Voltmeter

6625-00-775-0505 VOLTMETER 6625007750505 007750505

Managed by United States
NSN Created on 13 Mar 1968
Data Last Changed
May 2023
NATO Update Count
2
NATO Data Quality
ANRL Style E7 for 6625-00-775-0505 1/2
NSN 6625-00-775-0505 (Identification) 1/2
STYL Style C1 for 6625-00-775-0505 2/2
NSN 6625-00-775-0505 (Identification) 2/2

6625-00-775-0505 Stock and Availability Marketplace 6625-00-775-0505

Need Help?
Request a Quotation from participating marketplace vendors

6625-00-775-0505 Related Documents Related Documents 6625-00-775-0505 2+ Documents (More...)

Request a Quotation from participating marketplace vendors Request FinditParts 1801752 Shur Co 1801752
Updated Every Day 6625-00-775-0505 RQST NE Updated Every Day 6625-00-775-0505 RQST Updated Every Day
/fsg-66/fsc-6625/us 6625-00-775-0505 Voltmeter 6625007750505 007750505,1801752 Request a Quotation from
Upgrade for $1 a day Upgrade your Account Upgrade 6625-00-775-0523Voltmeter6625007750523 007750523 0DL3 1801752
Request a Quotation from participating marketplace vendors Request Subscribe to View Vendor Details... 1801752
Documents ( More... ) https//www.nsnlookup.com https//www.nsnlookup.com /fsg-66/fsc-6625/us 6625-00-775-0505

6625-00-775-0505 Demil Restrictions 6625-00-775-0505

DEMIL: A | DEMILI: | CRITICALITY: X | HMIC: P | PMIC: A | EDC: | ADPEC: 0

6625-00-775-0505 is a Voltmeter that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.

6625-00-775-0505 HTS and ScheduleB Import and Export 6625-00-775-0505

6625-00-775-0505 End Users End Users 6625-00-775-0505

US Navy (N9BN)
Effective Date:
1 Jul 2005
Former MOE Rule:
N9ND
Supplementary Collaborators:
HD

6625-00-775-0505 Manufacturers Approved Sources 6625-00-775-0505

6625-00-775-0505 Technical Data Datasheet 6625-00-775-0505

Characteristic
Specifications
FIIG
A310A0
Accuracy In Percent [APPN]
-2.0 To 2.0 At Full Scale Single Indicator All Ranges
Background Color [AQFY]
White Single Indicator Single Range
Circuit Attachment Method And Quantity [CTTD]
2 Screw And 2 Solder Lug
Circuit Current For Which Designed [AACT]
Dc
Dial Scale Marking Color [APMM]
Black And Green Single Indicator Single Range
Dielectric Withstanding Voltage In Volts [AAPB]
1500.0
Furnished Items And Quantity [AKYN]
Nut 2; Washer 2
Environmental Protection [ADZC]
Shock Resistant And Vibration Resistant
Features Provided [CBBL]
Knife Edge Pointer And Zero Adjuster
Material [MATT]
Steel
Measurement Range [BHMW]
-20.0 To 20.0 Volts, Dc Single Indicator Single Range
Meter Body Diameter Behind Mounting Flange [APSW]
2.070 Inches Nominal
Meter Depth Behind Mounting Flange [APST]
1.570 Inches Nominal
Mounting Arrangement Style [ANRL]
Six Hole/Stud Bolt Circle
Mounting Bolt Circle Diameter [AFFL]
2.380 Inches Nominal
Mounting Facility Type And Quantity [AXHR]
6 Screw And 6 Unthreaded Hole
Mounting Hole Diameter [ABTB]
0.138 Inches Minimum And 0.143 Inches Maximum
Movement Suspension Method [CTQL]
Jewel Pivot Base
Movement Type [AQEC]
Moving Coil, Permanent Magnet
Nuclear Hardness Critical Feature [NHCF]
Nonhardened
Fsc Application Data [ZZZV]
Test Set,Elect. Equip.
Installation Design [AMQY]
Panel
Indicator Type [AMKD]
Dial W/Pointer
Pointer Color [ASSS]
Black Single Indicator Single Range
Power Source [AWZJ]
External
Scale Graduation Type [BHDC]
Nonlinear Single Indicator Single Range
Overall Diameter [ADAV]
2.690 Inches Nominal
Overall Length [ABHP]
2.390 Inches Maximum
Special Features [FEAT]
Ruggedized
Special Test Features [SPCL]
Conforms To Mil-M-10304/24
Style Designator [STYL]
Round Flush Mtg

6625-00-775-0505 Stock, Inventory and Procurement DLA Procurement Analysis 6625-00-775-0505

DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

6625-00-775-0505 Management Data Management Data 6625-00-775-0505

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Oct 2022
Department of the Navy (DN)
EA
Subscribe
1
Oct 2021
Department of the Navy (DN)
EA
Subscribe
1
Oct 2020
Department of the Navy (DN)
EA
Subscribe
1
Oct 2019
Department of the Navy (DN)
EA
Subscribe
1

Navy Navy

Cognizance:
9B
Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg

6625-00-775-0505 Similar Items Similar Supply Items to 6625-00-775-0505

6625-00-775-0505 Freight Data Freight Information 6625-00-775-0505

6625-00-775-0505 has freight characteristics managed by the Food and Drug Administration (FDA).It has a National Motor Freight Classification (NMFC) of 061620. A Sub NMFC of X. It has a NMFC Description of ELECTRIC CURRENT TESTERS. 6625-00-775-0505 is rated as class 100 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34540 which rates the freight between FCL and LCL. 6625-00-775-0505 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 657 for ocean manifesting and military sealift. 6625-00-775-0505 is not classified as a special type of cargo when transported by water. 6625-00-775-0505 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

6625-00-775-0505 Packaging Data Packaging Data 6625-00-775-0505

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
--
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
No Requirement
PPP-C-795, Cellular Plastic Film Cushioning; or A-A-3129, Open Cell Plastic Cushioning; or PPP-C-1797, Polypropylene Foam Cushioning; or A-A-59136, Polyethylene Foam Cushioning
--
--
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
Any Suitable Fiber Box

6625-00-775-0505 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 6625-00-775-0505 October 2021

Criticality and Quality

Critical Item Code:
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
N

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Y
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: