An instrument which measures the relative amount of modulation present in an electrical wave form and is usually calibrated in percent or kilohertz (kilocycles) deviation. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. View more Modulation Meter

6625-00-432-7312 METER,MODULATION 6625004327312 004327312

Managed by United States
NSN Created on 5 May 1971
Data Last Changed
January 2023
NATO Update Count
10
NATO Data Quality
STYL Style D1 for 6625-00-432-7312 1/1
NSN 6625-00-432-7312 (Identification) 1/1

6625-00-432-7312 Stock and Availability Marketplace 6625-00-432-7312

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
6625-00-432-7312 RQST NE eBay
eBay Updated Every Day
6625-00-432-7312 RQST eBay
Amazon Updated Every Day
6625-00-432-7312 RQST NE Amazon

6625-00-432-7312 Related Documents Related Documents 6625-00-432-7312 3+ Documents (More...)

Documents 6625-01-075-3761 5+ Documents ( More... ) https//www.nsnlookup.com /fsg-66/fsc-6625/us 6625-00-432-7312
Modulation Meter 6625004327312 004327312 /www.nsnlookup.com /nato/nato-stock-numbers/inc Modulation
https//www.nsnlookup.com /nato/nato-stock-numbers/inc Modulation Meter (INC 16446) 20 Apr 1979 6625-00-432-7312
: 5 20 Oct 1969 6625-01-075-3761 Modulation Meter 9008RNCC: 3 | RNVC: 2 | DAC: 6 20 Apr 1979 6625-00-432-7312

6625-00-432-7312 Demil Restrictions 6625-00-432-7312

DEMIL: C | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: A | EDC: | ADPEC:

6625-00-432-7312 is a Modulation Meter that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is a US Munitions List or Commerce Control List Item where key elements must be removed and destroyed to prevent this item being restored or repaired. Only authorized parties may possess this item. This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.

6625-00-432-7312 HTS and ScheduleB Import and Export 6625-00-432-7312

6625-00-432-7312 End Users End Users 6625-00-432-7312

Republic of Korea (ZH01)
Effective Date:
1 Apr 1991
Portugal (ZP01)
Effective Date:
1 Apr 1991
Greece (ZU01)
Effective Date:
1 Aug 1995

6625-00-432-7312 Manufacturers Approved Sources 6625-00-432-7312

6625-00-432-7312 Technical Data Datasheet 6625-00-432-7312

Characteristic
Specifications
FIIG
A310A0
Accuracy In Percent [APPN]
-10.0/+10.0 At Full Scale Single Indicator All Ranges
Background Color [AQFY]
White Single Indicator All Ranges
Circuit Attachment Method And Quantity [CTTD]
2 Binding Post
Circuit Current For Which Designed [AACT]
Ac
Dial Scale Marking Color [APMM]
Black Single Indicator All Ranges
Features Provided [CBBL]
Portable
Frequency Rating [ACZB]
50.0 Hertz Minimum And 420.0 Hertz Maximum
Fsc Application Data [ZZZV]
Test Set,Electronic Equipment
Material [MATT]
Wood
Measurement Range [BHMW]
+0.0/+100.0 Kilohertz Single Indicator 3Rd Range
Measurement Range [BHMW]
+0.0/+20.0 Kilohertz Single Indicator 1St Range
Measurement Range [BHMW]
+0.0/+300.0 Kilohertz Single Indicator 4Th Range
Measurement Range [BHMW]
+0.0/+50.0 Kilohertz Single Indicator 2Nd Range
Nuclear Hardness Critical Feature [NHCF]
Nonhardened
Installation Design [AMQY]
Bench
Indicator Type [AMKD]
Dial W/Pointer
Pointer Color [ASSS]
Black Single Indicator All Ranges
Power Source [AWZJ]
External
Scale Graduation Type [BHDC]
Linear Single Indicator All Ranges
Scale Selection Method [BLSB]
Terminal
Sensitivity Rating [ANTG]
0.5 Volts
Overall Height [ABKW]
14.625 Inches Nominal
Overall Length [ABHP]
19.000 Inches Nominal
Overall Width [ABMK]
10.500 Inches Nominal
Phase [FAAZ]
Single
Special Features [FEAT]
Measures Deviation Over A Range From 0 To 1000 Khz At Rf Freq From 20 To 1000 Mhz
Style Designator [STYL]
Rectangular Or Square
Surface Treatment [SFTT]
Paint

6625-00-432-7312 Related Items NATO Stock Numbers Related to 6625-00-432-7312

6625-00-432-7312 Freight Data Freight Information 6625-00-432-7312

6625-00-432-7312 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061620. A Sub NMFC of X. It has a NMFC Description of ELECTRIC CURRENT TESTERS. 6625-00-432-7312 is rated as class 100 when transported by Less-Than Truckload (LTL) freight. 6625-00-432-7312 is rated as class 100 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 34540 which rates the freight between FCL and LCL. 6625-00-432-7312 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 657 for ocean manifesting and military sealift. 6625-00-432-7312 is not classified as a special type of cargo when transported by water. 6625-00-432-7312 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

6625-00-432-7312 Packaging Data Packaging Data 6625-00-432-7312

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
Packaging Data does not meet current MIL-STD-2073-1E
Storage Environment
Heated General Purpose – Heated 40 F and above

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
Over 10lb
Less than 85G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
--
26.0" H x 20.0" W x 20.5" L
--
--
--
Special Requirements
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
Special Requirement
Special Requirements – see Specific Instructions or Drawings provided
Special Requirements. See Specific Instructions or Drawings Provided
Special Requirements. See Specific Instructions or Drawings Provided
Special requirement – See specific instructions or drawings provided
--

Intermediate Pack Level

Quantity of Unit Packs
Container
Special requirement – See specific instructions or drawings provided