Premium Information is available for this item - Upgrade for $1 a day

6625-00-228-0902

Ammeter

6625002280902 002280902 5970

An instrument which measures electric current and is calibrated and marked in amperes or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. For current detecting type of devices, see GALVANOMETER. View more Ammeter

6625-00-228-0902 AMMETER 6625002280902 002280902

Managed by United States
NSN Created on 20 May 1973
Data Last Changed
November 2023
NATO Update Count
7
NATO Data Quality
6625-00-228-0902 AMMETER 6625002280902 002280902 1/1
NSN 6625-00-228-0902 (Generic Image) 1/1

6625-00-228-0902 Stock and Availability Marketplace 6625-00-228-0902

6625-00-228-0902 Related Documents Related Documents 6625-00-228-0902 1+ Documents (More...)

/fsg-66/fsc-6625/us 6625-00-228-0902 Ammeter 6625002280902 002280902,5970 /fsg-66/fsc-6625/us 6625-00
-228-0902 Ammeter 6625002280902 002280902,5970 Details... 5970 AMMETER RQST NS Request Quotation Subscribe
to View Vendor Details... 5970 AMMETER 3 /fsg-66/fsc-6625/us 6625-00- 228-0902 Ammeter 6625002280902

6625-00-228-0902 Demil Restrictions 6625-00-228-0902

DEMIL: A | DEMILI: | CRITICALITY: X | HMIC: P | PMIC: U | EDC: | ADPEC:

6625-00-228-0902 is a Ammeter that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.

6625-00-228-0902 End Users End Users 6625-00-228-0902

NASA (G900)
Effective Date:
1 Apr 1991

6625-00-228-0902 Manufacturers Approved Sources 6625-00-228-0902

6625-00-228-0902 Technical Data Datasheet 6625-00-228-0902

Characteristic
Specifications
Accuracy In Percent [APPN]
-2.0/+2.0 At Full Scale Single Indicator Single Range
Background Color [AQFY]
White Single Indicator Single Range
Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
1.880 Inches Nominal
Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
1.880 Inches Nominal
Circuit Attachment Method And Quantity [CTTD]
2 Threaded Stud
Circuit Current For Which Designed [AACT]
Dc
Dial Scale Marking Color [APMM]
Black Single Indicator Single Range
Material [MATT]
Plastic
Measurement Range [BHMW]
+0.0/+300.0 Milliamperes, Dc Single Indicator Single Range
Meter Body Diameter Behind Mounting Flange [APSW]
2.170 Inches Nominal
Meter Depth Behind Mounting Flange [APST]
1.450 Inches Nominal
Mounting Arrangement Style [ANRL]
Four Hole/Stud Rectangular/Square
Mounting Facility Type And Quantity [AXHR]
4 Threaded Stud
Mounting Stud Diameter [BLKZ]
0.112 Inches Nominal
Mounting Stud Length [ADAG]
0.530 Inches Nominal
Movement Suspension Method [CTQL]
Jewel Pivot Base
Movement Type [AQEC]
Moving Coil, Permanent Magnet
Installation Design [AMQY]
Panel
Overall Height [ABKW]
2.370 Inches Nominal
Overall Length [ABHP]
1.650 Inches Nominal
Overall Width [ABMK]
2.370 Inches Nominal
Special Features [FEAT]
For Hydrogen Gas Analyzer
Style Designator [STYL]
Rectangular Flush Mtg

6625-00-228-0902 Similar Items Similar Supply Items to 6625-00-228-0902

6625-00-228-0902 Freight Data Freight Information 6625-00-228-0902

6625-00-228-0902 has freight characteristics.. 6625-00-228-0902 has a variance between NMFC and UFC when transported by rail and the description should be consulted.