Premium Information is available for this item - Upgrade for $1 a day
6625-00-113-6353
Pulse Generator
6625001136353 001136353 110B 37000-610 426-4698
An electronic device which develops a discontinuous electrical potential with an abrupt rate of change of voltage which determines the harmonic content of the pulse train. The duration of a single pulse output is relatively short compared to the time of the recurrence cycle. See also GENERATOR, SINGLE PULSE; and GENERATOR, ELECTRONIC MARKER. View more Pulse Generator
![]()
January 2023
46

Marketplace 6625-00-113-6353
Request a Quotation from participating marketplace vendors
Related Documents 6625-00-113-6353 5+ Documents (More...)
... 110B GENERATOR,PULSE RQST NS Request Quotation Subscribe to View Vendor Details... 6625-00-113-6353
... ) https//www.nsnlookup.com /fsg-66/fsc-6625/us 6625-00-113-6353 Pulse Generator 6625001136353 001136353,110B
/fsg-59/fsc-5975/fr 5975-14-426-4698 Day 5975-14-426-4698 RQST NE Related Documents 5975-14-426-4698
59/fsc-5975/fr 5975-14-426-4698 Day 5975-14-426-4698 RQST NE Related Documents 5975-14-426-4698 6625001136353
RQST Updated Every Day 2520-00-426-4698 RQST NE Restrictions 2520-00-426-4698 DEMIL: B | DEMILI : |
https//www.nsnlookup.com /fsg-66/fsc-6625/us 6625-00-113-6353 Pulse Generator 6625001136353 001136353,110B
enable JavaScript in your web browser . 6640-20-007-7379Gel System Mini6640200077379 20007737909-528-110B
Pulse Generator 6625001136353 001136353,110B https//www.nsnlookup.com /fsg-59/fsc-5975/fr 5975
GENERATOR,SIGNAL 1 EA NS Request Quotation Subscribe to View Vendor Details... 110B GENERATOR,SIGNAL
GENERATOR,SIGNAL 1 EA NS Request Quotation Subscribe to View Vendor Details... 110B GENERATOR,SIGNAL
Restrictions 6625-00-113-6353
IUID Required
6625-00-113-6353 is a Pulse Generator that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 6625-00-113-6353
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6625-00-113-6353
- MOE Rule:
- B031
- Effective Date:
- 1 Apr 1991
- US Air Force (FGG4)
- Effective Date:
- 1 Nov 2000
- Former MOE Rule:
- FEE4
- Finland (WF01)
- Effective Date:
- 1 Jul 2009
- Brazil (YA01)
- Effective Date:
- 1 Aug 2000
- Spain (YB01)
- Effective Date:
- 1 Jun 1999
- Malaysia (YW01)
- Effective Date:
- 1 Apr 1991
- Canada (ZC01)
- Effective Date:
- 1 Apr 1991
- New Zealand (ZE01)
- Effective Date:
- 1 Apr 1991
- Germany (ZG01)
- Effective Date:
- 1 Apr 1991
- Republic of Korea (ZH01)
- Effective Date:
- 1 Apr 1991
- Denmark (ZS01)
- Effective Date:
- 1 Apr 1991
- Norway (ZT01)
- Effective Date:
- 1 Apr 1991
- Greece (ZU01)
- Effective Date:
- 1 Apr 1991
- Turkey (ZW01)
- Effective Date:
- 1 Nov 2005
Approved Sources 6625-00-113-6353
- Part Number
- Manufacturer
- Status
- 110B
- Manufacturer
- 52542 - Systron-Donner Corp (Obsolete)
- Original Design
- Original Design
- 37000-610
- 52542 - Systron-Donner Corp (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 426-4698
- A486G - Nimikkeistokeskus Ncb Finland (Active)
- NATO Reference
- NATO Reference
Datasheet 6625-00-113-6353
- Characteristic
- Specifications
- FIIG
- Specifications
- A32200
- Average Life Measurement [AFSU]
- Not Rated
- Basic Shape Style [AGTA]
- Rectangular Or Square
- Connection Type And Location [BJBP]
- Receptacle, Coaxial Front
- Connection Contact Type And Quantity [BJBW]
- 5 Receptacle, Coaxial Internal
- Control Type [AQZF]
- Local
- Entry Date [NTRD]
- 91-02-19
- External Ac Operating Voltage In Volts [BKFC]
- 115.0 Minimum 1St Voltage
- External Ac Operating Voltage In Volts [BKFC]
- 230.0 Maximum 2Nd Voltage
- Frequency Adjustment Type [BHTD]
- Stepped
- Frequency Per Channel [BHTB]
- 5.0 Hertz Minimum Operating Channel
- Frequency Per Channel [BHTB]
- 50.0 Megahertz Maximum Operating Channel
- Fsc Application Data [ZZZV]
- Support Of An/Ard-18 And An/Agm-69 Components
- Functional Classification [FCLS]
- Bb-1.1
- Circuit Construction Type [BHSX]
- Solid State
- Operating Ac Frequency In Hertz [BJBQ]
- 400.0 Maximum 2Nd Voltage
- Operating Ac Frequency In Hertz [BJBQ]
- 50.0 Minimum 1St Voltage
- Operating Control Method [ALBM]
- Manual
- Output Wave Shape [BJBJ]
- Pulse, Trigger
- Inclosure Type [AKNA]
- Encased
- Individual Section Quantity [AFBH]
- 2
- Individual Step Frequency [BHTF]
- 5.0 Hertz And 500.0 Hertz And 5.0 Kilohertz And 50.0 Kilohertz And 500.0 Kilohertz And 5.0 Megahertz
- Indicator Device Type And Quantity [BJBL]
- 6 Light
- Installation Design [AMQY]
- Free-Standing
- Polarity Per Channel [BHTS]
- Negative Operating Channel
- Polarity Per Channel [BHTS]
- Positive Operating Channel
- Pulse Repetition Rate Per Channel [BHTT]
- 5.000 Kilopulses Per Second Nominal Operating Channel
- Pulse Repetition Rate Per Channel [BHTT]
- 5.000 Megapulses Per Second Nominal Operating Channel
- Pulse Repetition Rate Per Channel [BHTT]
- 50.000 Megapulses Per Second Nominal Operating Channel
- Pulse Repetition Rate Per Channel [BHTT]
- 50.000 Pulses Per Second Nominal Operating Channel
- Pulse Repetition Rate Per Channel [BHTT]
- 50.000 Kilopulses Per Second Nominal Operating Channel
- Pulse Repetition Rate Per Channel [BHTT]
- 500.000 Kilopulses Per Second Nominal Operating Channel
- Pulse Repetition Rate Per Channel [BHTT]
- 500.000 Pulses Per Second Nominal Operating Channel
- Pulse Rise Time Per Channel [BHTQ]
- 5.000 Nanoseconds Nominal Operating Channel
- Pulse Decay Time Per Channel [BHTR]
- 10.000 Nanoseconds Minimum Operating Channel
- Pulse Decay Time Per Channel [BHTR]
- 50.000 Milliseconds Maximum Operating Channel
- Reference Data And Literature [RDAL]
- 33A1-8-630-1
- Signal Data Type Per Channel [BHTZ]
- Operating Channel Pulse
- Overall Height [ABKW]
- 5.250 Inches Nominal
- Overall Length [ABHP]
- 16.750 Inches Nominal
- Overall Width [ABMK]
- 13.750 Inches Nominal
- Phase [FAAZ]
- Single
Management Data 6625-00-113-6353
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Jan 2019
- Department of the Air Force (DF)
- EA
- Subscribe
- 1
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Air Force (DF)
- L
- R
- Refer To P000016916
- P000016916
- R
- Department of the Air Force (DF)
- L
- R
- Refer To P004354183
- P004354183
- R
- Department of the Air Force (DF)
- L
- R
- Refer To P004722018
- P004722018
- R
- Department of the Air Force (DF)
- L
- R
- Refer To P009313219
- P009313219
- R
Similar Supply Items to 6625-00-113-6353


















Freight Information 6625-00-113-6353
6625-00-113-6353 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061700. A Sub NMFC of A. It has a NMFC Description of ELEC APPLIANCES/INSTRUMENTS NOI. 6625-00-113-6353 is rated as class 400 when transported by Less-Than Truckload (LTL) freight. 6625-00-113-6353 is rated as class 85 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 34580 which rates the freight between FCL and LCL. 6625-00-113-6353 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 671 for ocean manifesting and military sealift. 6625-00-113-6353 is not classified as a special type of cargo when transported by water. 6625-00-113-6353 is not a consolidation, but exceeds 84" in at least one dimension. It may not be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 6625-00-113-6353
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- 16.8" H x 16.5" W x 5.3" L
- --
- --
- Over 10lb
- Less than 85G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- 3.1" H x 2.8" W x 1.5" L
- --
- --
- --
- Any Suitable Process
- 3.1" H x 2.8" W x 1.5" L
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- --
- --
- --
- PPP-B-1672, Type III, Telescoping Encapsulated Cushioning in Reusable Box
- No special marking
- --
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- --
- No Requirement