Premium Information is available for this item - Upgrade for $1 a day

6625-00-070-2164

Electrical Frequency Meter

6625000702164 000702164 ADD3N20627 ANN3N2184 66C42757

An instrument which measures the rate of regularly recurring variations in an electric current or voltage and is usually calibrated in Hertz (cycles per second or CPS). The value may be expressed by means of a pointer and calibrated dial vibrating reed or a digital read out display. For instruments which measure radio frequencies, see CALIBRATOR, FREQUENCY; and WAVEMENTER. Excludes: COUNTER ELECTRONIC DIGITAL. View more Electrical Frequency Meter

6625-00-070-2164 METER,ELECTRICAL FREQUENCY 6625000702164 000702164

Managed by United States
NSN Created on 13 Jul 1967
Data Last Changed
May 2023
NATO Update Count
8
NATO Data Quality
ANRL Style E5 for 6625-00-070-2164 1/2
NSN 6625-00-070-2164 (Identification) 1/2
STYL Style C1 for 6625-00-070-2164 2/2
NSN 6625-00-070-2164 (Identification) 2/2

6625-00-070-2164 Stock and Availability Marketplace 6625-00-070-2164

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
6625-00-070-2164 RQST NE eBay
eBay Updated Every Day
6625-00-070-2164 RQST eBay
Amazon Updated Every Day
6625-00-070-2164 RQST NE Amazon

6625-00-070-2164 Related Documents Related Documents 6625-00-070-2164 1+ Documents (More...)

ADD3N20627 ANN3N2184 66C42757 An instrument which measures the rate of regularly recurring variations
(Identification) 1/2 NSN 6625-00-070-2164 (Identification) 2/2 - - 1.
United States (US) 4. 6625-00-070-2164 Marketplace Restrictions Approved Sources Datasheet Management

6625-00-070-2164 Demil Restrictions 6625-00-070-2164

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: A | EDC: | ADPEC: 0

6625-00-070-2164 is a Electrical Frequency Meter that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.

6625-00-070-2164 HTS and ScheduleB Import and Export 6625-00-070-2164

6625-00-070-2164 End Users End Users 6625-00-070-2164

National Security Agency (DGX1)
Effective Date:
1 Apr 2006
Former MOE Rule:
DTX1
Supplementary Receivers:
TX

6625-00-070-2164 Manufacturers Approved Sources 6625-00-070-2164

6625-00-070-2164 Technical Data Datasheet 6625-00-070-2164

Characteristic
Specifications
FIIG
A310A0
Accuracy In Percent [APPN]
-2.0 To 2.0 At Full Scale Single Indicator Single Range
Background Color [AQFY]
White Single Indicator Single Range
Circuit Attachment Method And Quantity [CTTD]
2 Threaded Stud
Circuit Current For Which Designed [AACT]
Ac
Dial Scale Marking Color [APMM]
Black Single Indicator Single Range
Furnished Items And Quantity [AKYN]
Screws 3; Lock Washer 3; Hex Nuts 3
Features Provided [CBBL]
Zero Adjuster
Frequency Rating [ACZB]
60.0 Hertz Nominal
Material [MATT]
Plastic And Steel
Measurement Range [BHMW]
+388.0 To 412.0 Hertz Single Indicator Single Range
Meter Body Diameter Behind Mounting Flange [APSW]
2.210 Inches Maximum
Meter Depth Behind Mounting Flange [APST]
1.600 Inches Maximum
Mounting Arrangement Style [ANRL]
Three Hole/Stud Bolt Circle
Mounting Bolt Circle Diameter [AFFL]
2.440 Inches Nominal
Mounting Facility Type And Quantity [AXHR]
3 Threaded Stud
Movement Suspension Method [CTQL]
Jewel Pivot Base
Movement Type [AQEC]
Moving Coil, Permanent Magnet
Mounting Stud Diameter [BLKZ]
0.125 Inches Nominal
Mounting Stud Length [ADAG]
0.500 Inches Nominal
Nuclear Hardness Critical Feature [NHCF]
Nonhardened
Installation Design [AMQY]
Panel
Indicator Type [AMKD]
Dial W/Pointer
Pointer Color [ASSS]
Black Single Indicator Single Range
Power Source [AWZJ]
External
Scale Graduation Type [BHDC]
Linear Single Indicator Single Range
Scale Division Quantity [ABWG]
24 Single Indicator Single Range
Scale Selection Method [BLSB]
Terminal
Overall Diameter [ADAV]
2.695 Inches Maximum
Overall Length [ABHP]
2.650 Inches Maximum
Special Markings [MARK]
Red Line At 400 Hz
Style Designator [STYL]
Round Flush Mtg

6625-00-070-2164 Stock, Inventory and Procurement DLA Procurement Analysis 6625-00-070-2164

DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

6625-00-070-2164 Management Data Management Data 6625-00-070-2164

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Oct 2022
Defense Logistics Agency (DS)
EA
Subscribe
1
Oct 2021
Defense Logistics Agency (DS)
EA
Subscribe
1
Oct 2020
Defense Logistics Agency (DS)
EA
Subscribe
1
Mar 2020
Defense Logistics Agency (DS)
EA
Subscribe
1

6625-00-070-2164 Similar Items Similar Supply Items to 6625-00-070-2164

6625-00-070-2164 Freight Data Freight Information 6625-00-070-2164

6625-00-070-2164 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 136740. A Sub NMFC of Z. It has a NMFC Description of METERS ELEC/PARTS. 6625-00-070-2164 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 68820 which rates the freight between FCL and LCL. 6625-00-070-2164 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 657 for ocean manifesting and military sealift. 6625-00-070-2164 is not classified as a special type of cargo when transported by water. 6625-00-070-2164 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

6625-00-070-2164 Packaging Data Packaging Data 6625-00-070-2164

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
No Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
--
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
No Requirement
PPP-C-795, Cellular Plastic Film Cushioning; or A-A-3129, Open Cell Plastic Cushioning; or PPP-C-1797, Polypropylene Foam Cushioning; or A-A-59136, Polyethylene Foam Cushioning
--
--
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
Any Suitable Fiber Box

6625-00-070-2164 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 6625-00-070-2164 October 2021

Criticality and Quality

Critical Item Code:
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
N

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: