6625-00-008-0117
Waveguide Slotted Line
6625000080117 000080117 MLE71-4
An item consisting of a waveguide slotted section and suitable flanges for connecting into a waveguide transmission line. It is designed for use in microwave measurement. It must include an integral carriage which provides for applying longitudinal mechanical motion to a PROBE, WAVEGUIDE. It has a calibrated direct reading metric vernier scale and may have facilities for mounting a dial gage. It may include a probe. See also SLOTTED SECTION, WAVEGUIDE; LINE SECTION, RADIO FREQUENCY TRANSMISSION; INDICATOR, STANDING WAVE RATIO. View more Waveguide Slotted Line
November 2023
5

Marketplace 6625-00-008-0117
Request a Quotation from participating marketplace vendors
Related Documents 6625-00-008-0117 5+ Documents (More...)
Slotted Line 6625000080117,MLE71-4 Waveguide Slotted Line 6625000080117,MLE71-4 Waveguide Slotted Line
6625000080117,MLE71-4 Waveguide Slotted Line 6625000080117,MLE71-4 Waveguide Slotted Line 6625000080117
Waveguide Slotted Line 6625000080117,MLE71-4 6625000080117,MLE71-46625-00-008 Slotted Line 6625000080117
Slotted Line 6625993753013,1603 Restrictions Approved https// 6625-99-375-3013 https/ -4 46625000080117,MLE71-4
Waveguide Slotted Line 6625000080117,MLE71-4 www.nsnlookup.com /fsg-66/fsc-6625/us 6625-00-008-
Waveguide Slotted Line 6625009484720,J104A 6625004980925 4720 Waveguide Slotted Line 6625009484720 MLE71-4
/fr 6625-14-438-1421 Waveguide Slotted Line 6625144381421 Waveguide Slotted Line 5840144162373 6625000080117
,MLE71-4 910-2164 5840-14-416-2373 https//www.nsnlookup.com 6625/us 6625-00-692-4562 Waveguide Slotted
Waveguide Slotted Line 6625004456928,J347A Waveguide Slotted Line 6625144381421 6625006924562 , IM43U MLE71-4
Waveguide Slotted Line 6625004456928,J347A ,IM43U MLE71 https//www.nsnlookup.com /fsg-66/fsc-6625/us 6625-00-008-0117
Restrictions 6625-00-008-0117
6625-00-008-0117 is a Waveguide Slotted Line that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Approved Sources 6625-00-008-0117
- Part Number
- Manufacturer
- Status
- MLE71-4
- Manufacturer
- 30653 - Air Force Metrology And Calibration (Active)