Premium Information is available for this item - Upgrade for $1 a day
6530-01-503-5931
Surgical Instrument Sterilizer
6530015035931 015035931 02-2718 6530NCM022033 100S STERRAD 100
INC: 04495 Surgical Instrument Sterilizer
![]()
August 2023
4

 Marketplace  6530-01-503-5931
Request a Quotation from participating marketplace vendors
 Related Documents  6530-01-503-5931  5+ Documents (More...) 
Updated Every Day 6530-01-503-5931 RQST Updated Every Day 6530-01-503-5931 RQST NE Related Documents
6530-01-503-5931 5+ Documents ( More... ) https//www.nsnlookup.com /fsg-65/fsc-6530/us 6530-01-503-5931
6530-01-503- https//www.nsnlookup.com /fsg-65/fsc-6530/us 6530-01-505-3773 Validation Kit For The Sterrad 100
Day 6530-01-503-5931 RQST NE Restrictions 6530 https Datasheet 6530-01-505-3773 Restrictions 6530
6515011563008011563008 participating marketplace vendors Request Subscribe 41-5000 DEODORANT TAB 100S
6515011563008011563008 TAB 100S 4 BT NS Request Quotation Updated Every Day 6515-01-156-3008 RQST NE
/fsg-65/fsc-6530/us
-6530/us 6530-01-505-3771 Validation Kit 6530015053771015053771 Surgical Instrument Sterilizer 6530015035931
01-505-3771 CharacteristicSpecificationsFIIGA23900Special Features [FEAT]Validation Kit For The Sterrad 100
5930142160650 142160650,100S https//www.nsnlookup.com /fsg-66/fsc-6665/uk 6665-99-250-6334 Oxywarn 100S
Push Switch 5930142160650 142160650,100S Related Documents /us 7210-01-153- 7026 Pillowcase White 100S
 Restrictions  6530-01-503-5931
IUID Required
6530-01-503-5931 is a Surgical Instrument Sterilizer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
 Import and Export  6530-01-503-5931
- Schedule B
 - Subscribe to View Schedule B
 - HTS Code
 - Subscribe to View HTS Code
 
 End Users  6530-01-503-5931
- US Army (A911)   
- Effective Date:
  - 1 Dec 2006
 - Former MOE Rule:
 - A111
 
- US Air Force (FSGM)   
- Effective Date:
  - 1 Dec 2006
 - Former MOE Rule:
 - FSKX
 
- US Navy (N9BL)   
- Effective Date:
  - 1 Dec 2006
 - Former MOE Rule:
 - N9LM
 
- Turkey (ZW01)   
- Effective Date:
  - 1 Mar 2010
 
 Approved Sources  6530-01-503-5931
- Part Number
- Manufacturer
 - Status
 - 100S
  - Manufacturer
 -  04ES7 - Ethicon, Inc (Obsolete) 
- Original Design
  - Original Design
 - 02-2718
 -  89875 - Defense Logistics Agency Directorate (Active) 
- Incomplete Secondary Reference
  - Incomplete Secondary Reference
 - 6530NCM022033
 -  64616 - Defense Medical Standardization (Active) 
- Incomplete Secondary Reference
  - Incomplete Secondary Reference
 - STERRAD 100
 -  04ES7 - Ethicon, Inc (Obsolete) 
- Canceled/Obsolete
  - Canceled/Obsolete
 
 Datasheet  6530-01-503-5931
- Characteristic
- Specifications
 - FIIG
  - Specifications
 - T265-C
 - Motor Current Type [AZKJ]
 - Ac
 - Shelf Quantity [BGZL]
 - 2
 - Overall Height [ABKW]
 - 65.500 Inches Nominal
 - Overall Length [ABHP]
 - 40.000 Inches Nominal
 - Overall Width [ABMK]
 - 30.000 Inches Nominal
 - Part Name Assigned By Controlling Agency [CXCY]
 - Sterrad Sterilizer 65.5 X 40 X 30 In.
 - Special Features [FEAT]
 - 4Low Temp. Hydrogen Peroxide Gas Plasma Sterilization System;Built-In Wheels Provide Mobility; Shelf Dimensions: Upper 28 By 17 In., Lower 30 By 13 In.; Lead Crystal Display And Audible Alarm; 55 Min. Cycle Time; 208V; 60Hz; 20Amp; 3Phase System
 
 DLA Procurement Analysis  6530-01-503-5931
 Management Data  6530-01-503-5931
 Army
- Materiel Category and Inventory Manager:
 - C
 - Medical/Dental Materiel
 
- Appropriation and Budget Activity:
 - 2
 - Stock Fund Secondary Items
 
- Management Inventory Segment:
 - 1
 - Repairable Items(Exclusive of Insurance and Provisioning Items)
This code will be used to identify serviceable or unserviceable items of a durable nature, which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance. 
- Weapons System / End Item / Homogeneous Group:
 - 03
 - DLA/GSA Material
Not Potency Dated 
- Accounting Requirements:
 - N
 - Nonexpendable item.An item of Army property coded with an ARC of N in the AMDF.Nonexpendable items require property book accountability after issue from the stock record account.Commercial and fabricated items similar to items coded N in the AMDF are considered nonexpendable items.
 
 Navy
- Cognizance:
 - 9B
 - Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg 
- Special Material Content:
 - A
 - Medical
 
 Similar Supply Items to 6530-01-503-5931


















 Freight Information  6530-01-503-5931
6530-01-503-5931 has freight characteristics managed by the Bonneville Power Administration.It has a National Motor Freight Classification (NMFC) of 179320. A Sub NMFC of Z. It has a NMFC Description of STERILIZERS NOI. 6530-01-503-5931 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 88080 which rates the freight between FCL and LCL. 6530-01-503-5931 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 651 for ocean manifesting and military sealift. 6530-01-503-5931 is not classified as a special type of cargo when transported by water. 6530-01-503-5931 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air. 
 Packaging Data  6530-01-503-5931
- Responsible Activity
- Packaging Data Source
  - Primary Inventory Control Activity (PICA)
- --
  
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
 - Characteristics
 - Weight/Dimensions Category
 - Fragility
 - Item Preservation
  - Item Weight
 - --
- --
 - --
 - Over 10lb
 - Less than 85G
 - Special Requirement
  - --
 
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
 - Unit Weight
 - Unit Cube
 - Preservation Method
 - Cleaning/Drying
  - Unit Size
 - 1
- --
 - --
 - --
 - --
 - Special Requirements
  - --
 
- Preservation Material
- Wrapping Material
 - Cushioning/Dunnage
 - Cushioning Thickness
 - Container
 - Special Marking
  - Wrapping Material
 - Special Requirement
- Special Requirements – see Specific Instructions or Drawings provided
 - Special Requirements. See Specific Instructions or Drawings Provided
 - Special Requirements. See Specific Instructions or Drawings Provided
 - Special requirement – See specific instructions or drawings provided
 - Special requirements
  - Special Requirements – see Specific Instructions or Drawings provided
 
Intermediate Pack Level
- Quantity of Unit Packs
- Container
  - --
 
 Contracting Technical Data File (CTDF)  6530-01-503-5931  October 2021 
Criticality and Quality
- Critical Item Code:
 - Flight Safety:
 - Life Support:
 - Certified Samples:
 - Serialization:
 - First Article Test (FAT):
 - Certificate of Quality Compliance:
 - Production Lot Testing:
 - Special Testing:
 - Qualified Products List (QPL):
 
Commercial Properties
- Government Furnished Material:
 - Government Furnished Tooling:
 - Government Furnished Property:
 - Price Evaluation Code:
 - Diminshing Manufacturing Sources:
 - Warranty:
 - Commerical Off The Shelf (COTS):
 - End Item Application:
 - Auctioning Candidate:
 - Source of Procurement:
 - Contract Option:
 
Restrictions
- Boeing Rights Guard:
 - Export Controlled:
 - Controlled Technical Data Package (TDP):
 - Restricted Technical Data Package (TDP):
 - Contains Classified Material
 - Weapons System Indicator Code (WSIC):
 - N
 
Packaging Requirements
- Packaging Determination Table:
 - Packaging Review Code:
 - Special Packaging Instruction Number (SPIN):
 - Special Packaging Instruction Number Revision:
 - Special Packaging Instruction Number Date:
 - Pallet Reference Number Required: