6515-01-622-9460
Surgical Stapler
6515016229460 016229460 NTLC55
An item consisting of a stapling mechanism, an actuating lever and clinching blade. It is pre-loaded, disposable, and employed for routine skin and/or internal closure in various surgical procedures. View more Surgical Stapler
![]()
January 2023
3

Marketplace 6515-01-622-9460
Request a Quotation from participating marketplace vendors
Related Documents 6515-01-622-9460 2+ Documents (More...)
6515-01-622-9460 2+ Documents ( More... ) https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-622-9460
/fsg-65/fsc-6515/us 6515-01-622-9460 /fsg-65/fsc-6515/us 6515-01-622-9460 /fsg-65/fsc-6515/us 6515-01
Stapler And Cutter Unit 145230112 Unit 145784882 https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-622-9460
Surgical Stapler 6515016229460 016229460 for $1 a day Upgrade your Account Upgrade 6515-01-622-
Restrictions 6515-01-622-9460
6515-01-622-9460 is a Surgical Stapler that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 6515-01-622-9460
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6515-01-622-9460
- Brazil (YA01)
- Effective Date:
- 1 Oct 2013
Approved Sources 6515-01-622-9460
- Part Number
- Manufacturer
- Status
- NTLC55
- Manufacturer
- 3Q3U8 - Ethicon Endo-Surgery, Inc. (Obsolete)
- Original Design
- Original Design
Datasheet 6515-01-622-9460
- Characteristic
- Specifications
- FIIG
- Specifications
- T133-B
- Capacity [AXQD]
- 1.5 Milliliters And 1.8 Milliliters And 2.0 Milliliters
- Material And Location [ANNQ]
- Titanium Body
- Part Name Assigned By Controlling Agency [CXCY]
- Ethicon Endo-Surgery Linear Cutter
- Special Features [FEAT]
- Shaft Length 55 Mm; 3 Staggered Rows; Only Linear Cutter With 3 Row, 3-D Surgical Staple Technology; Up To 12 Firings; Single-Patient-Use Simultaneously Staples And Divides Tissue