Premium Information is available for this item - Upgrade for $1 a day
6515-01-600-7417
Cardiovascular Guide Wire Introducer
6515016007417 016007417 KCFW-6.0-18/38-90-RB-ANL1-HC
A device designed to facilitate passage for distally shaped tip through rotating hemostatic valve and dilatation catheters. Item is a component part of a INTRODUCER KIT, GUIDEWIRE, CARDIOVASCULAR. View more Cardiovascular Guide Wire Introducer
January 2023
1

Marketplace 6515-01-600-7417
Request a Quotation from participating marketplace vendors
Related Documents 6515-01-600-7417 5+ Documents (More...)
6515-01-600-7417 5+ Documents ( More... ) https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-600-7417
/fsg-65/fsc-6515/us 6515-01-600-7417 /fsg-65/fsc-6515/us 6515-01-600-7417 /fsg-65/fsc-6515/us 6515-01
Cardiovascular Guide Wire Introducer https Introducer 6515-01-622-6165 6515-01-600-7417 https//
6515-01-478-7055 https// 1051 www.nsnlookup.com https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-600-7417
www.nsnlookup.com Cardiovascular Guide Wire Introducer,395282 https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-600-7417
Cardiovascular Guide Wire Introducer us 6515-01-600-7417 /fsg-65/fsc-6515/us 6515-01 https//www.nsnlookup.com
www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-616-1227 https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-600-7417
Cardiovascular Guide Wire Introducer 6515-22-615-1908 -65/fsc-6515/us 6515-01-600-7417 https//www.nsnlookup.com
6515-01-558-5774 6515-01-616-1227 6515-22-615-1908 https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-600-7417
369-7962 6515-01-478-7055 6515-01-558-5774 6515-01-616-1227 6515-22-615-1908 6515-01-622-6165 6515-01-600-7417
Restrictions 6515-01-600-7417
6515-01-600-7417 is a Cardiovascular Guide Wire Introducer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 6515-01-600-7417
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6515-01-600-7417
- Turkey (ZW01)
- Effective Date:
- 1 Dec 2011
Approved Sources 6515-01-600-7417
- Part Number
- Manufacturer
- Status
- KCFW-6.0-18/38-90-RB-ANL1-HC
- Manufacturer
- 0DES3 - Wilson-Cook Medical Inc (Active)
- Primary Buy
- Primary Buy
Datasheet 6515-01-600-7417
- Characteristic
- Specifications
- FIIG
- Specifications
- T133-C
- Overall Length [ABHP]
- 90.0 Millimeters Nominal
- Part Name Assigned By Controlling Agency [CXCY]
- Flexor Check-Flo Introducers -Ansel Modification
- Special Features [FEAT]
- Used To Introduce Ballon, Closed And Nontapered-End Catherters Or Other Devices. Uniquely Fabricated Sheath Design Provides Maximum Flexibility Without Kinking Or Compression. 0.18 And 0.38 Inch Wire Compatible Dilators Included. Preformed Curves Combinded With Soft Distal Tip Allow Atraumatic Engagement Of Target Vessels. Short Dilator Tip Enhances Trackability And Facilitates Positioning Of Introducer Assembly In Tight Spaces. Radiopaque Band, Incorporated Within Sheath Material, Identifies Precise Location Of Sheath's Distal Tip For Positioning Accuracy. The Check-Flo Hemostasis Valve Accepts A Broad Range Of Sizes While Preventing Blood Reflux And Air Aspiration. Aq Hydrophilic Coating On Both Sheath And Dilator Provide An Extremely Lubricious Surface, Easing Introduction. Introducer Fr 6; Accepts Wirre Guide Diameter Inch .018/.038; Sheath Inner Diameter Inch .087
Similar Supply Items to 6515-01-600-7417


















Freight Information 6515-01-600-7417
6515-01-600-7417 has freight characteristics managed by Turkey.. 6515-01-600-7417 has a variance between NMFC and UFC when transported by rail and the description should be consulted.