Premium Information is available for this item - Upgrade for $1 a day
6515-01-581-5586
Bone Screw
6515015815586 015815586 6515NCM094050 14812 1896-5047S
A cylindrical rod incised with one or more helical or advancing spiral threads with smooth surfaces free from nicks, dents, burrs, and scratches suitable for use in orthopedic surgery and fabricated from implant-quality corrosion resisting material which is inert and biocompatible with human bones, tissues and internal chemistry. View more Bone Screw
![]()
August 2023
1

Marketplace 6515-01-581-5586
Request a Quotation from participating marketplace vendors
Related Documents 6515-01-581-5586 5+ Documents (More...)
United States (US) 4. 6515-01-581-5586 Marketplace Restrictions Approved Sources Datasheet Management
Updated Every Day 6515-01-581-5586 RQST NE Updated Every Day 6515-01-581-5586 RQST Updated Every Day
Account Upgrade 7643-01-404-4395Topographic Geospatial Products7643014044395 014044395V791X14812V791 14812
Account Upgrade 7643-01-404-4395Topographic Geospatial Products7643014044395 014044395V791X14812V791 14812
444-9115 Tapping Screw 5305014449115 014449115,14812 Products7643014044395 014044395V791X14812V791 14812
Account Upgrade 7643-01-684-0679Topographic Geospatial Products7643016840679 016840679E772X14812E772 14812
enable JavaScript in your web browser . 5999-01-188-5569Head Left Cover5999011885569 011885569 12-14812
99-444-9106 Pressure Head Box 5820994449106 994449106 Products7643996672584 996672584U711X14812U711 14812
https//www.nsnlookup.com /fsg-30/fsc-3020/fr 3020-14-366-3836 Spur Gear 3020143663836143663836,M589-14812
14-273-5605 Axe De Biellette 5315142735605 142735605 5569Head Left Cover5999011885569 011885569 12-14812
Restrictions 6515-01-581-5586
6515-01-581-5586 is a Bone Screw that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 6515-01-581-5586
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6515-01-581-5586
- US Army (A911)
- Effective Date:
- 1 Jan 2010
- US Air Force (FSGM)
- Effective Date:
- 1 Jan 2010
- US Marine Corps (MC55)
- Effective Date:
- 1 Jan 2010
- US Navy (N9BL)
- Effective Date:
- 1 Jan 2010
Approved Sources 6515-01-581-5586
- Part Number
- Manufacturer
- Status
- 1896-5047S
- Manufacturer
- 1CH83 - Stryker Sales, Llc (Active)
- Primary Buy
- Primary Buy
- 6515NCM094050
- 64616 - Defense Medical Standardization (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- 14812
- 89875 - Defense Logistics Agency Directorate (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
Datasheet 6515-01-581-5586
- Characteristic
- Specifications
- FIIG
- Specifications
- T133-M
- Material And Location [ANNQ]
- Titanium Overall
- Overall Length [ABHP]
- 47.5 Millimeters Nominal
- Special Features [FEAT]
- Fully Threaded Locking Screw, Tibial; Diameter: 5.0 Mm; Length: 47.5 Mm; Titanium
- Part Name Assigned By Controlling Agency [CXCY]
- Screw Tibial 5X47mm Titanium
DLA Procurement Analysis 6515-01-581-5586
Management Data 6515-01-581-5586
Army
- Materiel Category and Inventory Manager:
- C
- Medical/Dental Materiel
- Appropriation and Budget Activity:
- 2
- Stock Fund Secondary Items
- Management Inventory Segment:
- 2
- Non-Repairable Items(Exclusive of Insurance and Provisioning Items)
This code will be used to identify items, which are not reparable.
- Weapons System / End Item / Homogeneous Group:
- 03
- DLA/GSA Material
Not Potency Dated
- Accounting Requirements:
- X
- Expendable item.An item of Army property coded with an ARC of X in the AMDF. Expendable items require no formal accountability after issue from a stock record account.Commercial and fabricated items similar to items coded X in the AMDF are considered expendable items.
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
- Special Material Content:
- A
- Medical
Marine Corps
- Stores Account:
- 1
- Stock Fund Account Item
- Combat Essentiality:
- 5
- Critical Repair Part to a Combat Essential End Item
- Echelon Management:
- 54
- Operational Test:
- No Special Procedures
Similar Supply Items to 6515-01-581-5586


















Freight Information 6515-01-581-5586
6515-01-581-5586 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 056680. A Sub NMFC of X. It has a NMFC Description of DENTAL/MEDICAL/SURG INST R MACHINE. 6515-01-581-5586 is rated as class 150 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 32570 which rates the freight between FCL and LCL. 6515-01-581-5586 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 534 for ocean manifesting and military sealift. 6515-01-581-5586 is not classified as a special type of cargo when transported by water. 6515-01-581-5586 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 6515-01-581-5586
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- Bare Metal Item
- Over 10lb
- Less than 85G
- Special Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- Special Requirements
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- Special Requirement
- Special Requirements – see Specific Instructions or Drawings provided
- Special Requirements. See Specific Instructions or Drawings Provided
- Special Requirements. See Specific Instructions or Drawings Provided
- Special requirement – See specific instructions or drawings provided
- Special requirements
- Special Requirements – see Specific Instructions or Drawings provided
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- Special Requirement - see Specific Drawing or Instruction provided
- Special requirement – See specific instructions or drawings provided
Contracting Technical Data File (CTDF) 6515-01-581-5586 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- N
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: