6515-01-577-8737
Defibrillator/Monitor-Recorder System
6515015778737 015778737 99425-000122 99425-000052
A collection of items designed for use in the diagnosis and treatment of patients with cardiac arrest, arrhythmia, and those on an electrocardiograph monitor. May include monitor recorder module, defibrillator module, external paddles, external cable, cassette, electrodes, ruler, stylus, chart paper, and the like. May be mounted to field litter and field bed. View more Defibrillator-Monitor Recorder System
January 2023
2

Marketplace 6515-01-577-8737
Request a Quotation from participating marketplace vendors
Related Documents 6515-01-577-8737 5+ Documents (More...)
6515-01-577-8737 5+ Documents ( More... ) https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-577-8737
5+ Documents ( More... ) https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-577-8737 6515-01-
657-9817 6515-99-979-0734 6515-98-206-2680 6515-01-531-2215 6515-01-540-4551 6515-01-610-9089 6515-01-577-8737
designed for use in the https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-174-2406 610-9089 6515-01-577-8737
Defibrillator/Monitor-Recorder System 6515-01-540-4551 6515-01-610-9089 6515-01-577-8737 https/
Defibrillator/Monitor-Recorder System 6515-01-577-8737 657-9817 6515-99-979-0734 6515-98-206-2680
6515-01-531-2215 6515-01-540-4551 6515-01-610-9089 01-174-2406 610-9089 6515-01-577-8737 Defibrillator
Defibrillator/Monitor-Recorder System 540-4551 6515-01-610-9089 6515-01-577-8737 https/ https//
www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-601-6425 https 531-2215 6515-01-540-4551 6515-01-610-9089 6515-01-577-8737
Restrictions 6515-01-577-8737
6515-01-577-8737 is a Defibrillator/Monitor-Recorder System that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 6515-01-577-8737
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6515-01-577-8737
- Norway (ZT01)
- Effective Date:
- 1 Sep 2009
Approved Sources 6515-01-577-8737
- Part Number
- Manufacturer
- Status
- 99425-000122
- Manufacturer
- 28494 - Physio-Control Inc (Active)
- Primary Buy
- Primary Buy
- 99425-000052
- 28494 - Physio-Control Inc (Active)
- Original Design
- Original Design
Datasheet 6515-01-577-8737
- Characteristic
- Specifications
- FIIG
- Specifications
- A23800
- Model Number [AMWN]
- Lifepak 1000
- Special Features [FEAT]
- User Configurable: 150-360 Joules; Charge Time: 200 Joules In Less Than 7 Seconds; 3-Wire (Lead Ii) Monitoring Capability; Infant/Child Reduced Energy Defib Electrode; Rugged; Rust/Water Resistant; Primary Battery: Lithium Manganese Dioxide 9Li/Mn02), 12.0 Volt, 4.5 Amp-Hours; Min. 40 Minutes Ekg For Current Patient: Report Types: Continuouls Ecg, Summary, Event Log, Test Log Report
- Supplementary Features [SUPP]
- Operating Temperature: 0 To 50 Deg C; Height: 8.7 Cm; Width: 23.4 Cm; Depth: 27.7 Cm: Weight: 3.2 Kg
NATO Stock Numbers Related to 6515-01-577-8737
Freight Information 6515-01-577-8737
6515-01-577-8737 has freight characteristics.. 6515-01-577-8737 has a variance between NMFC and UFC when transported by rail and the description should be consulted.