6515-01-420-0861
Cardiovascular Balloon Dilation Catheter
6515014200861 014200861 12-240
An item designed to be inserted directly or through an introducer sheet to wrap tightly to assure smooth atraumatic entry, tracking, dilatation, and withdrawal during performance used in all phases of angioplasty procedures. View more Cardiovascular Balloon Dilation Catheter
![]()
January 2023
1

Marketplace 6515-01-420-0861
Request a Quotation from participating marketplace vendors
Related Documents 6515-01-420-0861 1+ Documents (More...)
RQST NE Updated Every Day 6515-01-420-0861 RQST Updated Every Day 6515-01-420-0861 RQST NE Related
Documents 6515-01-420-0861 1+ Documents ( More... ) https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515
Restrictions 6515-01-420-0861
6515-01-420-0861 is a Cardiovascular Balloon Dilation Catheter that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 6515-01-420-0861
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6515-01-420-0861
- MOE Rule:
- V540
- Effective Date:
- 1 Oct 1995
Approved Sources 6515-01-420-0861
- Part Number
- Manufacturer
- Status
- 12-240
- Manufacturer
- 0TS15 - Boston Scientific Corp Medi-Tech Div (Active)
- Primary Buy
- Primary Buy
Datasheet 6515-01-420-0861
- Characteristic
- Specifications
- FIIG
- Specifications
- T133-G
- Material And Location [ANNQ]
- Plastic, Polyethylene Overall
- Overall Length [ABHP]
- 75.000 Centimeters Nominal
- Overall Diameter [ADAV]
- 8.000 Millimeters Nominal
- Tip Diameter [AAZU]
- 0.037 Inches Nominal
- Disposition After Initial Use [ANGD]
- Disposable
- Features Provided [CBBL]
- Sterile
- Special Features [FEAT]
- Balloon Length, 4 Cm; Guide Wire Diameter, 0.035 Inch; 5.8 Fr.; New Blue Max, Poly-5, Short Taper Design; Rated Burst Pressure 17 (250) Atm (Psi); Used For High Pressure Angioplasty.
Similar Supply Items to 6515-01-420-0861


















Freight Information 6515-01-420-0861
6515-01-420-0861 has freight characteristics.. 6515-01-420-0861 has a variance between NMFC and UFC when transported by rail and the description should be consulted.