Premium Information is available for this item - Upgrade for $1 a day
6515-01-361-4014
Peritoneal Dialysis Catheter
6515013614014 013614014 NL850-1248
A component of an ADMINSTRATION SET, PERITONEAL DIALYSIS, which is inserted into the peritoneal cavity either by use of a trocar and cannula or through a surgical incision. View more Peritoneal Dialysis Catheter
January 2023
7
Marketplace 6515-01-361-4014
Request a Quotation from participating marketplace vendors
Related Documents 6515-01-361-4014 5+ Documents (More...)
Peritoneal Dialysis Catheter 6515013614014 6515/de 6515-12-186-2783 Peritoneal Dialysis Catheter
258-0954 6515-01-499-7407 6515-12-377-7649 6515-01-013-0921 6515-01-575-0046 6515-01-320-7903 6515-01-361-4014
Peritoneal Dialysis Catheter 6515013614014 Dialysis Catheter 6515121862783 258-0954 6515-01-499
258-0954 6515-01-499-7407 6515-12-377-7649 6515-01-013-0921 6515-01-575-0046 6515-01-320-7903 6515-01-361-4014
Peritoneal Dialysis Catheter 6515013614014 www.nsnlookup.com /fsg-65/fsc-6515/de 6515-12-186-2783
258-0954 6515-01-499-7407 6515-12-377-7649 6515-01-013-0921 6515-01-575-0046 6515-01-320-7903 6515-01-361-4014
Peritoneal Dialysis Catheter 6515013614014 186-2783 Peritoneal Dialysis Catheter 6515121862783
258-0954 6515-01-499-7407 6515-12-377-7649 6515-01-013-0921 6515-01-575-0046 6515-01-320-7903 6515-01-361-4014
Restrictions 6515-01-361-4014
6515-01-361-4014 is a Peritoneal Dialysis Catheter that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Import and Export 6515-01-361-4014
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6515-01-361-4014
- MOE Rule:
- V540
- Effective Date:
- 1 Apr 1991
Approved Sources 6515-01-361-4014
- Part Number
- Manufacturer
- Status
- NL850-1248
- Manufacturer
- 50060 - Baxter Healthcare Corp (Obsolete)
- Original Design
- Original Design
Datasheet 6515-01-361-4014
- Characteristic
- Specifications
- FIIG
- Specifications
- A22100
- Design Designation [ANEH]
- Raimondi
- Features Provided [CBBL]
- Nonsterile And Disposable And X-Ray Opacity
- Nominal Diameter [ANHF]
- 1.300 Millimeters
- Material And Location [ANNQ]
- Silicone Body
- Special Features [FEAT]
- 55-94 Mm. Medium Pressure Rated; Raimondi Spring; 94 Cm. Long; 1.3 Mm. I.D.,2.8 Mm. O.D.; Stainless Steel Spring; Silicone Wall; Designed To Resist Retrograde Flow
- Tip Type [ANFG]
- Pointed And Round
- Style Designator [STYL]
- Peritoneal Dialysis
NATO Stock Numbers Related to 6515-01-361-4014
Freight Information 6515-01-361-4014
6515-01-361-4014 has freight characteristics.. 6515-01-361-4014 has a variance between NMFC and UFC when transported by rail and the description should be consulted.