Premium Information is available for this item - Upgrade for $1 a day
6515-01-360-6468
Inhaler Tube Assembly
6515013606468 013606468 003750 P003750
An item consisting of a tubing circuit for use with a ventilator. May include a filter, adapters, caps, connectors, and the like. Excludes TUBE, INHALER. View more Inhaler Tube Assembly
January 2023
6
Marketplace 6515-01-360-6468
Request a Quotation from participating marketplace vendors
Related Documents 6515-01-360-6468 5+ Documents (More...)
/us 6515-00-555-2015 Inhaler Tube Assembly 6515005552015005552015 337-1802 6515-01-348-4157 6515-01-360-6468
01-348-4157 Inhaler Tube Assembly 6515013484157 013484157 011087793 337-1802 6515-01-348-4157 6515-01-360-6468
013606468 011087793 337-1802 6515-01-348-4157 6515-01-360-6468 6515-01-151-8024 6515-01-317-8806 Assembly
6515005552015 005552015 337-1802 6515-01-348-4157 6515-01-360-6468 6515-01-151-8024 4214 6515-01-266
6515-01-151-8024 6515-01-317-8806 Assembly 6515010955228 010955228 337-1802 6515-01-348-4157 6515-01-360-6468
fsg-65/fsc-6515/us 6515 Inhaler Tube Assembly 6515010955228010955228 337-1802 6515-01-348-4157 6515-01-360-6468
Assembly 6515011789759 011789759 Assembly 6515011087793 011087793 337-1802 6515-01-348-4157 6515-01-360-6468
Assembly 6515005552015 Inhaler Tube Assembly 6515011087793011087793 337-1802 6515-01-348-4157 6515-01-360-6468
6515-01-151-8024 6515-01-317-8806 Assembly 6515005552015 005552015 337-1802 6515-01-348-4157 6515-01-360-6468
6515-01-151-8024 6515-01-317-8806 Assembly 6515010955228 010955228 337-1802 6515-01-348-4157 6515-01-360-6468
Restrictions 6515-01-360-6468
6515-01-360-6468 is a Inhaler Tube Assembly that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Import and Export 6515-01-360-6468
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6515-01-360-6468
- MOE Rule:
- V540
- Effective Date:
- 1 Apr 1991
Approved Sources 6515-01-360-6468
- Part Number
- Manufacturer
- Status
- 003750
- Manufacturer
- 2T368 - Baxter Healthcare Corp (Obsolete)
- Original Design
- Original Design
- P003750
- 2T368 - Baxter Healthcare Corp (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 6515-01-360-6468
- Characteristic
- Specifications
- FIIG
- Specifications
- T117-A
- Connector Type [ANFJ]
- Luer Lock
- Disposition After Initial Use [ANGD]
- Disposable
- Material [MATT]
- Plastic
- Overall Length [ABHP]
- 39.000 Inches Nominal
- Special Features [FEAT]
- Individual Package; 89 Inch Pressure Sensing Line,0.250 Inch I.D.; 0.200 Inch I.D. Reducer For Pressure Sensing Line; With Nebulizer; For Use With Bennett Ma-1,Ma2(1),And Bear-1(2) Respiration Units; 6 Per Package
- Sterility [AKMX]
- Sterile
NATO Stock Numbers Related to 6515-01-360-6468
Freight Information 6515-01-360-6468
6515-01-360-6468 has freight characteristics.. 6515-01-360-6468 has a variance between NMFC and UFC when transported by rail and the description should be consulted.