Premium Information is available for this item - Upgrade for $1 a day
6515-01-352-9909
Cardiovascular Catheter
6515013529909 013529909 92-11-4-24 AH A92J072 533-620
A disposable item designed to be used either intra-arterially and/or intravenously for delivering radiopaque media to selected sites in the vascular system as in angiography. View more Cardiovascular Catheter
August 2023
6

Marketplace 6515-01-352-9909
Request a Quotation from participating marketplace vendors
Related Documents 6515-01-352-9909 1+ Documents (More...)
BUY NE FedMall Updated Every Day 6515-01-352-9909 RQST NE Updated Every Day 6515-01-352-9909 RQST
Updated Every Day 6515-01-352-9909 RQST NE Related Documents 6515-01-352-9909 1+ Documents ( More...
Restrictions 6515-01-352-9909
6515-01-352-9909 is a Cardiovascular Catheter that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 6515-01-352-9909
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6515-01-352-9909
- US Army (A911)
- Effective Date:
- 1 Dec 2006
- Former MOE Rule:
- A111
- US Air Force (FSGM)
- Effective Date:
- 1 Dec 2006
- Former MOE Rule:
- FSKX
- US Navy (N9BL)
- Effective Date:
- 1 Dec 2006
- Former MOE Rule:
- N9LM
- MOE Rule:
- V542
- Effective Date:
- 1 Apr 1991
Approved Sources 6515-01-352-9909
- Part Number
- Manufacturer
- Status
- 533-620
- Manufacturer
- 96FW3 - Cordis Us Corp (Active)
- Primary Buy
- Primary Buy
- 92-11-4-24 AH
- 66732 - Department Of The Army U S Army (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- A92J072
- 66732 - Department Of The Army U S Army (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- 533-620
- 21791 - Cordis Corp (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 533-620
- 1CXC8 - Cordis Corporation (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 6515-01-352-9909
- Characteristic
- Specifications
- FIIG
- Specifications
- A22100
- Style Designator [STYL]
- Femoral-Ventricular
- Design Designation [ANEH]
- Femoral-Ventricular
- Nominal Diameter [ANHF]
- 6.000 French
- Catheter Nominal Length [ANHQ]
- 100.000 Centimeters
- Inside Diameter [AARX]
- 0.050 Inches Nominal
- Material And Location [ANNQ]
- Plastic, Polyurethane Overall
- Tip Type [ANFG]
- Tapered
- Core Fabrication Method [ANFS]
- Woven
- Unit Package Quantity [AGUC]
- 5
- Special Features [FEAT]
- Maximum Guide Wire Accepted,0.038 Inch; Pg/5
- Part Name Assigned By Controlling Agency [CXCY]
- Catheter 6Fr 100Cm 5S
DLA Procurement Analysis 6515-01-352-9909
Management Data 6515-01-352-9909
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Oct 2022
- Department of the Army (DA)
- PG
- Subscribe
- 1
- PG
- Oct 2021
- Department of the Army (DA)
- PG
- Subscribe
- 1
- PG
- Oct 2020
- Department of the Navy (DN)
- PG
- Subscribe
- 1
- PG
- Oct 2019
- Defense Logistics Agency (DS)
- PG
- Subscribe
- 1
- PG
- Feb 1992
- Veterans Administration (VA)
- PG
- Subscribe
- PG
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Army (DA)
- A
- K
- U/I Contains 5 Ea
- 00000000005EA
- K
- Department of the Air Force (DF)
- F
- K
- U/I Contains 5 Ea
- 00000000005EA
- K
- Department of the Navy (DN)
- N
- K
- U/I Contains 5 Ea
- 00000000005EA
- K
- Defense Logistics Agency (DS)
- I
- K
- U/I Contains 5 Ea
- 00000000005EA
- K
- Veterans Administration (VA)
- V
- K
- U/I Contains 5 Ea
- 00000000005EA
- K
Army
- Materiel Category and Inventory Manager:
- C
- Medical/Dental Materiel
- Appropriation and Budget Activity:
- 2
- Stock Fund Secondary Items
- Management Inventory Segment:
- 2
- Non-Repairable Items(Exclusive of Insurance and Provisioning Items)
This code will be used to identify items, which are not reparable.
- Weapons System / End Item / Homogeneous Group:
- 03
- DLA/GSA Material
Not Potency Dated
- Accounting Requirements:
- X
- Expendable item.An item of Army property coded with an ARC of X in the AMDF. Expendable items require no formal accountability after issue from a stock record account.Commercial and fabricated items similar to items coded X in the AMDF are considered expendable items.
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
- Special Material Content:
- A
- Medical
NATO Stock Numbers Related to 6515-01-352-9909
Freight Information 6515-01-352-9909
6515-01-352-9909 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 056680. A Sub NMFC of X. It has a NMFC Description of DENTAL/MEDICAL/SURG INST R MACHINE. 6515-01-352-9909 is rated as class 150 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 32570 which rates the freight between FCL and LCL. 6515-01-352-9909 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 651 for ocean manifesting and military sealift. 6515-01-352-9909 is not classified as a special type of cargo when transported by water. 6515-01-352-9909 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 6515-01-352-9909
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- Over 10lb
- Less than 85G
- Special Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- Special Requirements
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- Special Requirement
- Special Requirements – see Specific Instructions or Drawings provided
- Special Requirements. See Specific Instructions or Drawings Provided
- Special Requirements. See Specific Instructions or Drawings Provided
- Special requirement – See specific instructions or drawings provided
- Special requirements
- Special Requirements – see Specific Instructions or Drawings provided
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- --
Procurement History 6515-01-352-9909 3 Records
Contracting Technical Data File (CTDF) 6515-01-352-9909 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: