6515-01-315-6197
Patient Vital Signs Monitor
6515013156197 013156197 106 LCD BASIC A89J292 SP0200-97-D-8021 PROPAQ 106 LCD BASIC PROPAQ 106 3290026/P 3290006
A portable, battery operated item which may include a blood pressure cuff, adapter, universal cuff, electrocardiogram cabling, direct plug-in adapter, and other related items. Item is designed to be used to monitor a patient's blood pressure, pulse and temperature. It is also used in the intensive care unit, emergency, operating and recovery rooms. View more Patient Vital Signs Monitor
January 2023
16
Marketplace 6515-01-315-6197
Request a Quotation from participating marketplace vendors
Related Documents 6515-01-315-6197 5+ Documents (More...)
Air Force Medical Logistics Office (Active) Incomplete Secondary Reference RNCC 5 RNVC 1 DAC 4 SP0200-97-D-8021
Air Force Medical Logistics Office (Active) Incomplete Secondary Reference RNCC 5 RNVC 1 DAC 4 SP0200-97-D-8021
Air Force Medical Logistics Office (Active) Incomplete Secondary Reference RNCC 5 RNVC 1 DAC 4 SP0200-97-D-8021
Air Force Medical Logistics Office (Active) Incomplete Secondary Reference RNCC 5 RNVC 1 DAC 4 SP0200-97-D-8021
Patient Vital Signs Monitor 6515013156197 Upgrade 6515-01-315-6197Patient Vital Signs Monitor6515013156197
013156197 106 LCD BASIC A89J292 SP0200-97-D-8021 Air Force Medical Logistics Office (Active) Incomplete
Air Force Medical Logistics Office (Active) Incomplete Secondary Reference RNCC 5 RNVC 1 DAC 4 SP0200-97-D-8021
Air Force Medical Logistics Office (Active) Incomplete Secondary Reference RNCC 5 RNVC 1 DAC 4 SP0200-97-D-8021
Documents 6515-01-433-1373 2+ Documents ( More... ) https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-315-6197
Patient Vital Signs Monitor 6515013156197 Allyn Protocol Inc (CAGE Code 0M4S4) 4SP0200-97-D-8021RNCC
Restrictions 6515-01-315-6197
IUID Required
6515-01-315-6197 is a Patient Vital Signs Monitor that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 6515-01-315-6197
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6515-01-315-6197
- New Zealand (ZE01)
- Effective Date:
- 1 Nov 1993
- United Kingdom (ZK01)
- Effective Date:
- 1 Mar 1994
Approved Sources 6515-01-315-6197
- Part Number
- Manufacturer
- Status
- 106 LCD BASIC
- Manufacturer
- 0M4S4 - Welch Allyn Protocol Inc (Obsolete)
- Incomplete Reference
- Incomplete Reference
- PROPAQ 106 LCD BASIC
- 0M4S4 - Welch Allyn Protocol Inc (Obsolete)
- Primary Buy
- Primary Buy
- PROPAQ 106
- 0M4S4 - Welch Allyn Protocol Inc (Obsolete)
- Primary Buy
- Primary Buy
- A89J292
- 66735 - Air Force Medical Logistics Office (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- SP0200-97-D-8021
- 89875 - Defense Logistics Agency (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- PROPAQ 106
- U5872 - Draeger Medical Uk Ltd (Active)
- Secondary Buy
- Secondary Buy
- 3290026/P
- U5872 - Draeger Medical Uk Ltd (Active)
- Secondary Buy
- Secondary Buy
- 3290006
- U5872 - Draeger Medical Uk Ltd (Active)
- Secondary Buy
- Secondary Buy
Datasheet 6515-01-315-6197
- Characteristic
- Specifications
- FIIG
- Specifications
- T133-F
- Current Type [ACDC]
- Ac
- Voltage In Volts [ELEC]
- 120.0
- Frequency In Hertz [FREQ]
- 60.0
- Portability [APCB]
- Portable
- Furnished Items And Quantity [AKYN]
- Battery,Rechargeable Sealed Lead Acid-1; Recorder,Strip Chart-1; Screen,Lcd-1
- Special Features [FEAT]
- Lightweight; Monitors Ecg,Heart Rate,Two Invasive Blood Pressure Channels; One Non-Invasive Blood Pressure Channel,Pulse,And Temperature; Displays Selected Parameters On Lcd Screen And Strip Chart Recorder; Rechargeable Sealed Lead Acid Battery; Indicates Voltage And When Battery Is Charging; For Use In Bedside,Emergency Transport,Or Operating Room Monitoring
- Part Name Assigned By Controlling Agency [CXCY]
- Monitor Patient Vital Signs Cord/Battery 120V 60Hz Ac Portable
DLA Procurement Analysis 6515-01-315-6197
Management Data 6515-01-315-6197
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Jun 2011
- Defense Logistics Agency (DS)
- EA
- Subscribe
- 1
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Defense Logistics Agency (DS)
- I
- V
- Discontinued W/O Replacement
- V
NATO Stock Numbers Related to 6515-01-315-6197
Freight Information 6515-01-315-6197
6515-01-315-6197 has freight characteristics managed by the Bonneville Power Administration.It has a National Motor Freight Classification (NMFC) of 056680. A Sub NMFC of X. It has a NMFC Description of DENTAL/MEDICAL/SURG INST R MACHINE. 6515-01-315-6197 is rated as class 150 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 32570 which rates the freight between FCL and LCL. 6515-01-315-6197 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 534 for ocean manifesting and military sealift. 6515-01-315-6197 is not classified as a special type of cargo when transported by water. 6515-01-315-6197 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 6515-01-315-6197
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- Over 10lb
- Less than 85G
- Special Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- Special Requirements
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- Special Requirement
- Special Requirements – see Specific Instructions or Drawings provided
- Special Requirements. See Specific Instructions or Drawings Provided
- Special Requirements. See Specific Instructions or Drawings Provided
- Special requirement – See specific instructions or drawings provided
- Special requirements
- Special Requirements – see Specific Instructions or Drawings provided
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- --
Contracting Technical Data File (CTDF) 6515-01-315-6197 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: