Maxillofacial Bone Surgery Instrument Set
6515012733582 012733582 7-0504-P
A collection of items designed for use with the maxillofacial bone surgery implant set. It is for use in maxillofacial trauma surgical procedures. It may consist of a case, aluminum, perforated, chuck quick coupling, drill bits of various size diameters, lower upper tray for instruments, forceps, holding small plate, pliers, tap diameters, trocar, screwderiver, retractors, and other related items. View more Maxillofacial Bone Surgery Instrument Set
August 2023
7

Marketplace 6515-01-273-3582
Request a Quotation from participating marketplace vendors
Related Documents 6515-01-273-3582 5+ Documents (More...)
6515-01-273-3582 5+ Documents ( More... ) https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-273-3582
/fsg-65/fsc-6515/us 6515-01-273-3582 /fsg-65/fsc-6515/us 6515-01-273-3582 /fsg-65/fsc-6515/us 6515-01
6515-01-679-1586 https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-273-3582 Maxillofacial Bone
Surgery Instrument Set 6515/us 6515-01-273-3582 Maxillofacial Bone Surgery Instrument Set 6515/us 6515
Stock Numbers Related to 6515-01-679-1598 https https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-273-3582
Maxillofacial Bone Surgery Instrument Set us 6515-01-273-3582 /fsg-65/fsc-6515/us 6515-01 https
Maxillofacial Bone Surgery Instrument Set 6515-01-679-1586 7537 6515/us 6515-01-273-3582 https/
Stock Numbers Related to 6515-99-269-1797 6515-14-353-0764 6515-14-551-4494 6515-99-269-1797 6515-01-273-3582
Instrument Set Account Upgrade 6515-01-273-3582Maxillofacial Bone Surgery Instrument Set6515012733582 012733582
7-0504-P 65/fsc-6515/uk 6515-99-269-1797 6515-01-273-3582 https//www.nsnlookup.com /fsg-65/fsc-6510/
Restrictions 6515-01-273-3582
6515-01-273-3582 is a Maxillofacial Bone Surgery Instrument Set that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 6515-01-273-3582
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6515-01-273-3582
- US Army (A911)
- Effective Date:
- 1 Dec 2006
- Former MOE Rule:
- A111
- US Air Force (FSGM)
- Effective Date:
- 1 Dec 2006
- Former MOE Rule:
- FSKX
- US Navy (N9BL)
- Effective Date:
- 1 Dec 2006
- Former MOE Rule:
- N9LM
- Turkey (ZW01)
- Effective Date:
- 1 Nov 2009
Approved Sources 6515-01-273-3582
- Part Number
- Manufacturer
- Status
- 7-0504-P
- Manufacturer
- 64616 - Defense Medical Standardization (Active)
- Primary Buy
- Primary Buy
Datasheet 6515-01-273-3582
- Characteristic
- Specifications
- FIIG
- Specifications
- A23800
- Supply Items And Quantities [AJKC]
- 6515012738644 Drill Bits 1.5 Mm Dia 60/85 Mm Long 2; 6515012338869 1.5 Mm 85/110 Mm Long 2; 6515012229972 2 Mm 75/100 Mm Long 2; 6515012338873 2 Mm 100/125 Mm Long 2; 6515012747169 2.7 Mm 75/100 Mm Long 2; 6515012738645 2.7 Mm 100/125 Mm Long 2
- Nonsupply Items And Quantities [AJKD]
- C/O Case,Aluminum,Perforated 1; Chuck,Quick Coupling 1; Drill Guide,1.5 Mm Dia 1; 2.0 Mm Dia 1; 2.7 Mm Dia 1; Drill Guide,Mandibular,Compression Plate 1; Drill Guide,Mandibular,Long,Compression Plate 1; Drill Guide,Sleeve,2.0 Mm Dia 1; Forceps,Holding,Small Plate,Extra Long 1; Forceps,Reduction,With Points,Extra Long 1; Forceps Reduction,Mandibular 1; Gage,Depth,Small,Extra Long 1; Gage,Mini-Depth,Extra Long 1; Handle-Mini,Tap And Drill,2.0 Mm And 2.7 Mm 1; Irons,Bending,Small 2; Pliers,Bending 1; Retractor Hohmann,8 Mm Blade Width,Small 1; Retractor,Hohman; Broad Shank,Long 1; Ring,Cheek Retractor 1
- Special Features [FEAT]
- Compatible With Maxillofacial Bone Surgery Implant Set,6515-01-275-3986; For Use In Maxillofacial Trama Surgical Procedures
- Supplementary Features [SUPP]
- C/O Continued; Roll Comp 1; Screwdriver Cruciform 1; Screwdriver Hexagonal Small 1; Tap,2 Mm 45/55 Mm Long 2; 2 Mm 90/100 Mm Long; 2.7 Mm 75/100 Mm Long; 2.7 Mm 100/125 Mm Long 2; Tap,Sleeve 3.5 Mm 1; Templates,Bending,Small,5 And 7 Hole 2; Tray,Removable Lower 1; Upper 1; Trocar,W/Handle 1; Trocar Removable Metal Point Large 1; Small 1
- Part Name Assigned By Controlling Agency [CXCY]
- Instrument Set Maxillofacial Bone Surg F/Trauma Surg Procedures
DLA Procurement Analysis 6515-01-273-3582
Management Data 6515-01-273-3582
Army
- Materiel Category and Inventory Manager:
- C
- Medical/Dental Materiel
- Appropriation and Budget Activity:
- 2
- Stock Fund Secondary Items
- Management Inventory Segment:
- 2
- Non-Repairable Items(Exclusive of Insurance and Provisioning Items)
This code will be used to identify items, which are not reparable.
- Weapons System / End Item / Homogeneous Group:
- 03
- DLA/GSA Material
Not Potency Dated
- Accounting Requirements:
- N
- Nonexpendable item.An item of Army property coded with an ARC of N in the AMDF.Nonexpendable items require property book accountability after issue from the stock record account.Commercial and fabricated items similar to items coded N in the AMDF are considered nonexpendable items.
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
- Special Material Content:
- A
- Medical
Similar Supply Items to 6515-01-273-3582


















Freight Information 6515-01-273-3582
6515-01-273-3582 has freight characteristics managed by the Bonneville Power Administration.. 6515-01-273-3582 has a variance between NMFC and UFC when transported by rail and the description should be consulted.
Contracting Technical Data File (CTDF) 6515-01-273-3582 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: