Premium Information is available for this item - Upgrade for $1 a day
6515-01-140-5311
Periosteal Elevator
6515011405311 011405311 40-7401 5867407401 SK40-7401 27-821
An item used for elevating periosteum and muscle from bone. View more Periosteal Elevator

June 2023
6

 Marketplace  6515-01-140-5311
 Marketplace  6515-01-140-5311
Request a Quotation from participating marketplace vendors
 Related Documents  6515-01-140-5311  1+ Documents (More...)
 Related Documents  6515-01-140-5311  1+ Documents (More...) 
BUY NE FedMall Updated Every Day 6515-01-140-5311 RQST NE Updated Every Day 6515-01-140-5311 RQST
Updated Every Day 6515-01-140-5311 RQST NE Related Documents 6515-01-140-5311 1+ Documents ( More...
 Restrictions  6515-01-140-5311
 Restrictions  6515-01-140-5311
6515-01-140-5311 is a Periosteal Elevator that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
 Import and Export  6515-01-140-5311
 Import and Export  6515-01-140-5311
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
 End Users  6515-01-140-5311
 End Users  6515-01-140-5311
- US Army (A911)   - Effective Date:
- 1 Dec 2006
- Former MOE Rule:
- A111
- US Air Force (FSGM)   - Effective Date:
- 1 Dec 2006
- Former MOE Rule:
- FSKX
- US Navy (N9BL)   - Effective Date:
- 1 Dec 2006
- Supplementary Collaborators:
- GTHD
 Approved Sources  6515-01-140-5311
 Approved Sources  6515-01-140-5311
- Part Number- Manufacturer
- Status
- 40-7401
- Manufacturer
-  55187 - Sklar Corporation (Active) - Primary Buy
- Primary Buy
- 5867407401
-  9C381 - Owens & Minor Distribution Inc (Active) - Secondary Buy
- Secondary Buy
- SK40-7401
-  07TA6 - Cardinal Health 200, Llc (Active) - Secondary Buy
- Secondary Buy
- 27-821
-  07920 - Miltex Instrument Company Inc (Obsolete) - Canceled/Obsolete
- Canceled/Obsolete
 Datasheet  6515-01-140-5311
 Datasheet  6515-01-140-5311
- Characteristic- Specifications
- FIIG
- Specifications
- T133-A
- Design Designation [ANEH]
- Key
- Material And Location [ANNQ]
- Steel, Corrosion Resisting Overall
- Design Form [ARJD]
- Curved
- Blade Shape [AJMH]
- Curved Up
- Blade Width [AEAF]
- 0.375 Inches Nominal
- Blade Edge Type [BZNQ]
- Blunt
- Overall Length [ABHP]
- 7.500 Inches Nominal
- Special Features [FEAT]
- Solid Handle; Used For Elevating Periosteal And Muscle From Bone
- Part Name Assigned By Controlling Agency [CXCY]
- Elevator Periosteal Key Design Crvd Up 7.50" Lg Blunt Edge Crs
 DLA Procurement Analysis  6515-01-140-5311
 DLA Procurement Analysis  6515-01-140-5311
 Management Data  6515-01-140-5311
 Management Data  6515-01-140-5311
- Effective Date
- Organization- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Oct 2022
- Department of the Army (DA)- EA
- Subscribe
- 1
- EA
- Oct 2021
- Department of the Navy (DN)- EA
- Subscribe
- 1
- EA
- Oct 2020
- Department of the Navy (DN)- EA
- Subscribe
- 1
- EA
- Oct 2019
- Department of the Army (DA)- EA
- Subscribe
- 1
- EA
- MOE
- USC- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Navy (DN)
- N- R
- Refer To Non-Std Non-Dmsb Rev
- NON-STD NON-DMSB REV
- R
 Army
 Army
- Materiel Category and Inventory Manager:
- C
- Medical/Dental Materiel
 
- Appropriation and Budget Activity:
- 2
- Stock Fund Secondary Items
 
- Management Inventory Segment:
- 2
- Non-Repairable Items(Exclusive of Insurance and Provisioning Items)
 This code will be used to identify items, which are not reparable.
 
- Weapons System / End Item / Homogeneous Group:
- 03
- DLA/GSA Material
 Not Potency Dated
 
- Accounting Requirements:
- D
- Durable item.An item of Army property coded with an ARC of D in the AMDF. Durable items do not require property book accountability after issue from the stock record account but do require hand receipt control when issued to the user. Commercial and fabricated items similar to items coded D in the AMDF are considered durable items.
 
 Navy
 Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
 Naval Inventory Control Point, Mechanicsburg
 
- Special Material Content:
- A
- Medical
 
 Similar Supply Items to 6515-01-140-5311
 Similar Supply Items to 6515-01-140-5311


















 Freight Information  6515-01-140-5311
 Freight Information  6515-01-140-5311
6515-01-140-5311 has freight characteristics managed by the Bonneville Power Administration.It has a National Motor Freight Classification (NMFC) of 056680. A Sub NMFC of X. It has a NMFC Description of DENTAL/MEDICAL/SURG INST R MACHINE. 6515-01-140-5311 is rated as class 150 when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 32570 which rates the freight between FCL and LCL. 6515-01-140-5311 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 651 for ocean manifesting and military sealift. 6515-01-140-5311 is not classified as a special type of cargo when transported by water. 6515-01-140-5311 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air. 
 Packaging Data  6515-01-140-5311
 Packaging Data  6515-01-140-5311
- Responsible Activity- Packaging Data Source
- Primary Inventory Control Activity (PICA)- --
Item Pack Level (Unpackaged)
- Item Size- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --- --
- --
- Over 10lb
- Less than 85G
- Special Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1- --
- --
- --
- --
- Special Requirements
- --
- Preservation Material- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- Special Requirement- Special Requirements – see Specific Instructions or Drawings provided
- Special Requirements. See Specific Instructions or Drawings Provided
- Special Requirements. See Specific Instructions or Drawings Provided
- Special requirement – See specific instructions or drawings provided
- Special requirements
- Special Requirements – see Specific Instructions or Drawings provided
Intermediate Pack Level
- Quantity of Unit Packs- Container
- --
 Contracting Technical Data File (CTDF)  6515-01-140-5311  October 2021
 Contracting Technical Data File (CTDF)  6515-01-140-5311  October 2021 
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required:

 
 