Premium Information is available for this item - Upgrade for $1 a day
6515-01-092-0040
Hypodermic Syringe
6515010920040 010920040 8881-114030 SYR140
A device consisting of a barrel, a piston or plunger, and has provisions for attaching a needle for use in administering hypodermic injections. The item may be glass, glass and metal, plastic, or plastic and metal. It may be designed for single injection (disposable), or multiple use. It does not include a needle. Excludes SYRINGE,CARTRIDGE and SYRINGE AND NEEDLE,HYPODERMIC. View more Hypodermic Syringe
January 2023
17

Marketplace 6515-01-092-0040
Request a Quotation from participating marketplace vendors
Related Documents 6515-01-092-0040 4+ Documents (More...)
RQST NE Updated Every Day 6515-01-092-0040 RQST Updated Every Day 6515-01-092-0040 RQST NE Related Documents
6515-01-092-0040 4+ Documents ( More... ) https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-092-0040
Semiconductor Device5961997452205 99745220511A4/114030 https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-092-0040
Hypodermic Syringe 6515010920040 010920040 a day Upgrade your Account Upgrade 6515-01-092-0040Hypodermic
https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-092-0040 Hypodermic Syringe 6515010920040 010920040
Hypodermic Syringe 6515010920040 010920040 -0552 Drahtbuegel 2540121890552 121890552 https https
Restrictions 6515-01-092-0040
6515-01-092-0040 is a Hypodermic Syringe that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 6515-01-092-0040
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6515-01-092-0040
- Australia (ZA01)
- Effective Date:
- 1 Jan 2010
- Portugal (ZP01)
- Effective Date:
- 1 Apr 1991
Approved Sources 6515-01-092-0040
- Part Number
- Manufacturer
- Status
- 8881-114030
- Manufacturer
- 06135 - The Kendall Company Lp (Replaced)
- Original Design
- Original Design
- SYR140
- Z7N43 - Diagnostic & Medical Pty Ltd (Active)
- Secondary Buy
- Secondary Buy
- 8881-114030
- 05963 - Sherwood Medical Co (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 8881-114030
- 6VKK4 - Covidien Sales Llc (Active)
- Advisory Reference
- Advisory Reference
Datasheet 6515-01-092-0040
- Characteristic
- Specifications
- FIIG
- Specifications
- T133-B
- Barrel Material [AWAC]
- Plastic
- Barrel Tip Design [BZQB]
- Concentric
- Capacity [AXQD]
- 140.000 Milliliters
- Features Provided [CBBL]
- Disposable And Nonsterile
- Plunger Marking [BZPZ]
- Dark Colored Base
- Plunger Material [ATZE]
- Plastic
- Plunger Thumb Rest Type [BZQC]
- Button
- Scale Smallest Increment [AWAG]
- 5.000 Milliliters And 0.250 Ounces
- Scale Type [ATEQ]
- Double
- Part Name Assigned By Controlling Agency [CXCY]
- Syringe Hypodermic 140Ml Cap Luer Lock Tip W/O Needle Autocl 20S
- Special Features [FEAT]
- Autoclavable; Without Needle; For Use In Procedures Requiring Injection Of Large Quantities Of Medication Or Diagnostic Dyes
- Tip Material [AQQT]
- Plastic
- Tip Type [ANFG]
- Luer Lock
DLA Procurement Analysis 6515-01-092-0040
Management Data 6515-01-092-0040
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Jan 2014
- Defense Logistics Agency (DS)
- PG
- Subscribe
- PG
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Defense Logistics Agency (DS)
- I
- K
- U/I Contains 20 Ea
- K
- Defense Logistics Agency (DS)
- I
- V
- Discontinued W/O Replacement
- V
Similar Supply Items to 6515-01-092-0040


















Freight Information 6515-01-092-0040
6515-01-092-0040 has freight characteristics managed by the Bonneville Power Administration.It has a National Motor Freight Classification (NMFC) of 056960. A Sub NMFC of Z. It has a NMFC Description of SYRINGES. 6515-01-092-0040 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 32575 which rates the freight between FCL and LCL. 6515-01-092-0040 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 534 for ocean manifesting and military sealift. 6515-01-092-0040 is not classified as a special type of cargo when transported by water. 6515-01-092-0040 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Contracting Technical Data File (CTDF) 6515-01-092-0040 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Y
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: