Premium Information is available for this item - Upgrade for $1 a day
6515-01-074-9862
Hemodialysis Apparatus Dialyzer
6515010749862 010749862 6515-00-C97-6885 6515-01-C25-7646 LUNDIA 3N LUNDIA IC-3N LUN10-3N LUNDIA 10 DIALYZER GLP 11.5 3N
An item which is used in the hemodialysis process as a component of an artificial kidney apparatus for cleansing the blood by ultrafiltration. It may be in reusable form with provision for replacing the membrane or may be totally self-contained in disposible form. View more Hemodialysis Apparatus Dialyzer
January 2023
14

Marketplace 6515-01-074-9862
Request a Quotation from participating marketplace vendors
Related Documents 6515-01-074-9862 5+ Documents (More...)
/ 4-- ACI-3N /fsg-65/fsc-6515/us 6515 -01-074-9862 Hemodialysis Apparatus Dialyzer 010749862 Signal Data
-1000A -3N,INPUT:1000 /5A,OKTPUT:4-2- ACI-3N,0-1000A ,24VDC https/ 4-- ACI - Restrictions 6515-01-074
Hemodialysis Apparatus Dialyzer 010749862 Dialyzer6515010749862 010749862 6515-00-C97-6885 6515
-01-C25-7646 LUNDIA 3N LUNDIA IC-3N LUN10-3N LUNDIA 10 DIALYZER Signal Data Converter - ACI-3N STROEMCONVERTERO
Converter 6625222576514222576514 ACI-3N,INPUT:3000/5A,HJAELPESP.- ACI-3N,0-3000A,24VDC,3000 ACI-3N,INPUT
,0-3000A,24VDC,3000/5A,4-- ACI-3NSTROEMCONVERTERO-3000A,ACI-3N Managed 3N /fsg-66/fsc-6625/dk 6625-22
MS21266-3N GROMMET,NONMETALLIC 62 EA NS Request Quotation Subscribe to View Vendor Details...
https/ 101 501 CR1/3N https 6135123299914 ,CR1-3N 101 501 CR1/3N https// ,CR1-3N 101 501 / Cell 101
,ACI-3N Managed Converter 6625222576514222576514 ACI-3N,INPUT:3000/5A https/ https//www.nsnlookup.com
STROEMCONVERTER,ACI-3N,0-1000A -3N,INPUT:1000 /5A,OKTPUT:4-2- ACI-3N,0-1000A ,24VDC https/ 4-- ACI -
Restrictions 6515-01-074-9862
6515-01-074-9862 is a Hemodialysis Apparatus Dialyzer that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 6515-01-074-9862
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6515-01-074-9862
- MOE Rule:
- V542
- Effective Date:
- 1 Apr 1991
Approved Sources 6515-01-074-9862
- Part Number
- Manufacturer
- Status
- LUNDIA 3N
- Manufacturer
- 52493 - Gambro Inc (Obsolete)
- Primary Buy
- Primary Buy
- LUNDIA IC-3N
- 52493 - Gambro Inc (Obsolete)
- Primary Buy
- Primary Buy
- 6515-00-C97-6885
- 89875 - Defense Logistics Agency Directorate (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- 6515-01-C25-7646
- 89875 - Defense Logistics Agency Directorate (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- LUN10-3N
- 52493 - Gambro Inc (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- LUNDIA 10 DIALYZER
- 52493 - Gambro Inc (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- GLP 11.5
- 52493 - Gambro Inc (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 3N
- 52493 - Gambro Inc (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 6515-01-074-9862
- Characteristic
- Specifications
- FIIG
- Specifications
- T117-E
- Dialyzer Element Form [CSQR]
- Plate
- Body Material [AAFZ]
- Plastic
- Membrane Thickness In Microns [CSXD]
- 10.5
- Filtering Surface Area [ADNL]
- 1.0 Square Meters
- Sterility [AKMX]
- Sterile
- Disposition After Initial Use [ANGD]
- Disposable
- Special Features [FEAT]
- Priming Volume 91.0 Ml.; Ultrafiltration In Vivo 3.5 Ml.; Multiple Layers (17 For Blood,34 For Dialysate) Cupropane Membrane; Parallel Flow; 8 Per Case
Management Data 6515-01-074-9862
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Jul 1984
- Veterans Administration (VA)
- BX
- Subscribe
- BX
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Veterans Administration (VA)
- V
- K
- U/I Contains 8 Ea
- 00000000008EA
- K
NATO Stock Numbers Related to 6515-01-074-9862
Freight Information 6515-01-074-9862
6515-01-074-9862 has freight characteristics.. 6515-01-074-9862 has a variance between NMFC and UFC when transported by rail and the description should be consulted.