Premium Information is available for this item - Upgrade for $1 a day
6515-01-023-0873
Spinal Anesthesia Set
6515010230873 010230873 1112 4705
INC: 14362 Spinal Anesthesia Set
January 2023
5

Marketplace 6515-01-023-0873
Request a Quotation from participating marketplace vendors






Related Documents 6515-01-023-0873 5+ Documents (More...)
Subscribe to View Vendor Details... 1112 ANESTHESIA SET,SPINAL 922 EA NS Request Quotation 4705 ANESTHESIA
5120-01-678-1112 RQST Updated Every Day 5120-01-678-1112 RQST NE Related Documents 5120-01-678-1112
2530-27-057-4705 DEMIL: | DEMILI : | CRITICALITY : | HMIC : | PMIC : | EDC: | ADPEC : 2530-27-057-4705
https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-023-0873 Spinal Anesthesia Set 6515010230873 010230873

/fsg-51/fsc-5120/us
5120-01-678-1112 3+ Documents ( More... ) https//www.nsnlookup.com /fsg-51/fsc-5120/us 5120-01-678-1112
us 6515-01-023-0873 Spinal Anesthesia Set 6515010230873 010230873 Quotation 4705 ANESTHESIA ANESTHESIA
6510-27-004-4705 5+ Documents ( More... ) https//www.nsnlookup.com /fsg-65/fsc-6510/tr 6510-27-004-4705
https//www.nsnlookup.com /fsg-65/fsc-6515/us 6515-01-023-0873 Spinal Anesthesia Set 6515010230873 010230873

/fsg-66/fsc-6645/us
Impregnated Cast Bandage 6510270044705,AS358 4705 https//www.nsnlookup.com /fsg-65/fsc-6515/us https
Spinal Anesthesia Set 6515010230873 010230873 0873 Spinal Anesthesia Set 6515010230873010230873
Restrictions 6515-01-023-0873
6515-01-023-0873 is a Spinal Anesthesia Set that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Import and Export 6515-01-023-0873
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6515-01-023-0873
- MOE Rule:
- V540
- Effective Date:
- 1 Apr 1991
Approved Sources 6515-01-023-0873
- Part Number
- Manufacturer
- Status
- 1112
- Manufacturer
- 06135 - The Kendall Company Lp (Replaced)
- Original Design
- Original Design
- 4705
- 06135 - The Kendall Company Lp (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 6515-01-023-0873
- Characteristic
- Specifications
- FIIG
- Specifications
- A23800
- Component Quantity [AJJW]
- 22
- Nonsupply Items And Quantities [AJKD]
- Polystyrene Tray W/Lid,1; Outer Wrap,1; 22 Gage 3-1/2 Inch Long Spinal Needle With Stylet,1; 3 Cc Syringe,1; 25 Gage,5/8 Inch Long Skin Infiltration Needle,1; 5 Cc Glass Syringe,1; 20 Gage,1-1/2 Inch Long Filter Needle,1; Drug Information Sheet,1; Splash Shield,1; Fenestrated Drape,1; Removable Prep Tray,1; Prep Applicator,2; 3 By 3 Inch Gauze Sponge,3; Adhesive Bandage,1; Underpad,1; Ethylene Oxide Indicator Strip,1; 2 Ml. Ampul 1% Lidocaine Hydrochloride,1; 2 Ml. Ampul 1% Pontocaine,1; 3 Ml. Ampul 10% Dextrose,1
- Special Features [FEAT]
- Sterile,Disposable
Similar Supply Items to 6515-01-023-0873


















Freight Information 6515-01-023-0873
6515-01-023-0873 has freight characteristics.. 6515-01-023-0873 has a variance between NMFC and UFC when transported by rail and the description should be consulted.