Premium Information is available for this item - Upgrade for $1 a day
6510-01-619-8699
Impregnated Cast Bandage
6510016198699 016198699 6510NCM139290 715775 00890601400 MMM76415A 76415A
A dressing that stiffens and becomes rigid when either exposed to an appropriate light source, water, or any other hardening material. For use in immobilizing various parts of the body. View more Impregnated Cast Bandage
![]()
August 2023
5

Marketplace 6510-01-619-8699
Request a Quotation from participating marketplace vendors
Related Documents 6510-01-619-8699 5+ Documents (More...)
/fsg-65/fsc-6510/us
Every Day 76415A RQST NE Updated Every Day 6510-01-619-8699 RQST NE Updated Every Day 6510-01-619-8699
... ) https//www.nsnlookup.com /fsg-65/fsc-6510/us 6510-01-619-8699 Impregnated Cast Bandage 6510016198699
Impregnated Cast Bandage 6510016198699 619-8699Impregnated Cast Bandage6510016198699 016198699
6510NCM139290 715775 00890601400 MMM76415A 76415A Every Day 76415A RQST NE Updated Every Day 6510-01-
www.nsnlookup.com /fsg-47/fsc-4730/it 4730-15-001-1187 Hose Coupling 4730150011187 150011187,715775 715775
for $1 a day Upgrade your Account Upgrade 1650-01-049-2692Fluid Filter Body1650010492692 010492692 715775
day Upgrade your Account Upgrade 5960-00-230-5320Electron Tube5960002305320 002305320 MIL-E-1/498 715775
day Upgrade your Account Upgrade 5960-00-230-5320Electron Tube5960002305320 002305320 MIL-E-1/498 715775
day Upgrade your Account Upgrade 5960-00-230-5320Electron Tube5960002305320 002305320MIL-E-1/498 715775
day Upgrade your Account Upgrade 5960-00-230-5320Electron 6510NCM139290 715775 day Upgrade your Account
Restrictions 6510-01-619-8699
6510-01-619-8699 is a Impregnated Cast Bandage that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 6510-01-619-8699
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6510-01-619-8699
- US Army (A911)
- Effective Date:
- 1 Jun 2013
- US Air Force (FSGM)
- Effective Date:
- 1 Jun 2013
- US Marine Corps (MC55)
- Effective Date:
- 1 Jun 2013
- US Navy (N9BL)
- Effective Date:
- 1 Jun 2013
- Brazil (YA01)
- Effective Date:
- 1 Dec 2014
- New Zealand (ZE01)
- Effective Date:
- 1 Dec 2014
Approved Sources 6510-01-619-8699
- Part Number
- Manufacturer
- Status
- 00890601400
- Manufacturer
- 67239 - Zimmer, Inc. (Active)
- Primary Buy
- Primary Buy
- 76415A
- 9KEZ3 - Solventum Us Llc (Active)
- Primary Buy
- Primary Buy
- 6510NCM139290
- 64616 - Defense Medical Standardization (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- 715775
- 89875 - Defense Logistics Agency Directorate (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- MMM76415A
- 0PMN3 - Medline Industries, Lp (Active)
- Secondary Buy
- Secondary Buy
- 76415A
- 76381 - 3M Company (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 6510-01-619-8699
- Characteristic
- Specifications
- FIIG
- Specifications
- T00600
- Length [ABRY]
- 15.000 Inches Nominal
- Width [ABGL]
- 4.000 Inches Nominal
- Setting Time [ARMP]
- 4 Minutes Nominal
- Impregnation Material [CXKJ]
- Polyurethane Resin
- Features Provided [CBBL]
- Individually Wrapped
- Special Features [FEAT]
- One-Step Cast Splint; Multiple Layers Of Knitted Fiberglass Fabric Impregnated With Polyurethane Resin; Covered On One Side By An Air And Moisture Permeable Non-Woven Fabric And Fast Drying Air And Moisture Permeable Open Cell Foam On The Other Side; Exposure To Moisture Or Water Causes A Chemical Reaction Which Makes The Splint Become Rigid; Each Splint Packaged In A Sealed Foil Pouch; Set Time: Approx. 3 To 4 Minutes; Package Of 10
- Part Name Assigned By Controlling Agency [CXCY]
- Scotchcast 10S
- Protective Storage Feature [AJCN]
- Controlled Room Temperature
DLA Procurement Analysis 6510-01-619-8699
Management Data 6510-01-619-8699
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Oct 2022
- Department of the Air Force (DF)
- PG
- Subscribe
- 1
- PG
- Oct 2021
- Defense Logistics Agency (DS)
- PG
- Subscribe
- 1
- PG
- Oct 2020
- Defense Logistics Agency (DS)
- PG
- Subscribe
- 1
- PG
- Oct 2019
- Department of the Army (DA)
- PG
- Subscribe
- 1
- PG
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Army (DA)
- A
- K
- U/I Contains 10 Ea
- 00000000010EA
- K
- Department of the Air Force (DF)
- F
- K
- U/I Contains 10 Ea
- 00000000010EA
- K
- US Marine Corps (DM)
- M
- K
- U/I Contains 10 Ea
- 00000000010EA
- K
- Department of the Navy (DN)
- N
- K
- U/I Contains 10 Ea
- 00000000010EA
- K
- Defense Logistics Agency (DS)
- I
- K
- U/I Contains 10 Ea
- 00000000010EA
- K
Army
- Materiel Category and Inventory Manager:
- C
- Medical/Dental Materiel
- Appropriation and Budget Activity:
- 2
- Stock Fund Secondary Items
- Management Inventory Segment:
- 2
- Non-Repairable Items(Exclusive of Insurance and Provisioning Items)
This code will be used to identify items, which are not reparable.
- Weapons System / End Item / Homogeneous Group:
- 01
- DLA/GSA Material
Type 1 (Non-Extendable) Potency Dated Item
- Accounting Requirements:
- X
- Expendable item.An item of Army property coded with an ARC of X in the AMDF. Expendable items require no formal accountability after issue from a stock record account.Commercial and fabricated items similar to items coded X in the AMDF are considered expendable items.
Navy
- Cognizance:
- 9B
- Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
- Special Material Content:
- A
- Medical
Marine Corps
- Stores Account:
- 1
- Stock Fund Account Item
- Combat Essentiality:
- 5
- Critical Repair Part to a Combat Essential End Item
- Echelon Management:
- 54
- Operational Test:
- No Special Procedures
Similar Supply Items to 6510-01-619-8699


















Freight Information 6510-01-619-8699
6510-01-619-8699 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 056828. A Sub NMFC of Z. It has a NMFC Description of MEDICAL SUPPLIES,VIZ. 6510-01-619-8699 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 68045 which rates the freight between FCL and LCL. 6510-01-619-8699 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 534 for ocean manifesting and military sealift. 6510-01-619-8699 is not classified as a special type of cargo when transported by water. 6510-01-619-8699 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Procurement History 6510-01-619-8699 1 Records
Contracting Technical Data File (CTDF) 6510-01-619-8699 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- N
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- N
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: