Premium Information is available for this item - Upgrade for $1 a day
6145-01-312-2236
Electrical Wire
6145013122236 013122236 MIL-W-22759/44 VG95218-1002 VG95218-T1002 M22759/44-28-5 T-121351/28-5 H3844282-5 45941700-5 R40328-5 515 570-5 31-E5-56-631-5 55A0112-28-5 BR22759/44-28-5 37AA-0112-28-5 59/44-28-5 BR22759/441/28-5 37-00204-5
A single metallic conductor of solid, stranded, or tinsel construction, designed to carry current in an electrical circuit. It may be a bare or insulated, may have metalic covering sheath, shield or and additional jacket. Refers to bulk quantities only. For items that are solid or stranded, insulated or uninsulated, and have the chemical composition specified but no conductivity (electrical properties) see WIRE,(as modified), Includes Litz wire and insulated/uninsulated armored, and ground wire. Excludes BRAID, WIRE; FUSE WIRE; RESISTANCE WIRE and MAGNET WIRE. View more Electrical Wire
November 2023
20
Marketplace 6145-01-312-2236
Request a Quotation from participating marketplace vendors
Related Documents 6145-01-312-2236 5+ Documents (More...)
WIRE,ELECTRICAL 1041 EA NS Request Quotation M22759/44-28-7 WIRE,ELECTRICAL 6 VG95218-T1002 515
WIRE,ELECTRICAL 1819 EA NS VG95218-T1002 515 570-1 55A0112-28-1 45941700-1 R40328-1 T-121351/28-1
WIRE,ELECTRICAL 1041 EA NS Request Quotation M22759/44-28-7 WIRE,ELECTRICAL 6 VG95218-T1002 515
WIRE,ELECTRICAL 1819 EA NS VG95218-T1002 515 570-1 55A0112-28-1 45941700-1 R40328-1 T-121351/28-1
WIRE,ELECTRICAL 1041 EA NS Request Quotation M22759/44-28-7 WIRE,ELECTRICAL 6 VG95218-T1002 515
WIRE,ELECTRICAL 1819 EA NS VG95218-T1002 515 570-1 55A0112-28-1 45941700-1 R40328-1 T-121351/28-1
VG95218-T1002 M22759/44-18-1 31-E5-56-636-1 BR22759/44-18-1 R40318-1 55A0112-18-1 T-121351/18-1
515 585-1 H3844184-1 45942200-1 MIL-W-22759/44 59/44-18-1 BR22759/441/18-1 37-00209-1 37AA-0112-18-1
M22759/44-26-7 WIRE,ELECTRICAL 5889 EA NS Request Quotation MIL-W-22759/44 WIRE,ELECTRICAL 1819 EA NS
WIRE,ELECTRICAL 1819 EA NS Request Quotation M22759/44-26-1 WIRE,ELECTRICAL VG95218-T1002 515 570
Restrictions 6145-01-312-2236
6145-01-312-2236 is a Electrical Wire that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item contains Silver.
Import and Export 6145-01-312-2236
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6145-01-312-2236
- Germany (ZG01)
- Effective Date:
- 1 Apr 1991
Approved Sources 6145-01-312-2236
- Part Number
- Manufacturer
- Status
- M22759/44-28-5
- Manufacturer
- 81349 - Military Specifications (Active)
- Definitive Standard
- Definitive Standard
- MIL-W-22759/44
- 81349 - Military Specifications (Active)
- Incomplete Standard
- Incomplete Standard
- VG95218-1002
- D9477 - Baainbw Verteidigungsgerate-Normen (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- VG95218-T1002
- D9477 - Baainbw Verteidigungsgerate-Normen (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- T-121351/28-5
- 71124 - Prysmian Cables And Systems Usa, Llc (Active)
- Secondary Buy
- Secondary Buy
- H3844282-5
- 12703 - Judd Wire Inc. (Active)
- Secondary Buy
- Secondary Buy
- 45941700-5
- D1427 - Nexans Deutschland Industries Gmbh & (Active)
- Secondary Buy
- Secondary Buy
- R40328-5
- D2773 - Prysmian Kabel Und Systeme Gmbh (Active)
- Secondary Buy
- Secondary Buy
- 515 570-5
- S3708 - Huber And Suhner Ltd (Active)
- Secondary Buy
- Secondary Buy
- 31-E5-56-631-5
- K1390 - Amo Special Cables Limited (Active)
- Secondary Buy
- Secondary Buy
- 55A0112-28-5
- D1973 - Tyco Electronics Raychem Gmbh (Active)
- Secondary Buy
- Secondary Buy
- 55A0112-28-5
- K1010 - Tyco Electronics Uk Ltd (Active)
- Secondary Buy
- Secondary Buy
- BR22759/44-28-5
- 71124 - Prysmian Cables And Systems Usa, Llc (Active)
- Secondary Buy
- Secondary Buy
- 55A0112-28-5
- 06090 - Te Connectivity Corporation (Active)
- Secondary Buy
- Secondary Buy
- 37AA-0112-28-5
- 05973 - Champlain Cable Corp Sub Of Huber (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- 59/44-28-5
- 05973 - Champlain Cable Corp Sub Of Huber (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
- BR22759/441/28-5
- 71124 - Prysmian Cables And Systems Usa, Llc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 37-00204-5
- 05973 - Champlain Cable Corp Sub Of Huber (Obsolete)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 6145-01-312-2236
- Characteristic
- Specifications
- FIIG
- Specifications
- A077A0
- Color [HUES]
- Green 1St Position Cover Single Conductor
- Conductor Form [CXCW]
- Stranded Single Conductor
- Cross Section Outside Diameter [ADVL]
- 0.027 Inches Nominal
- Cross-Sectional Shape Style [AAGR]
- Round
- Material [MATT]
- Copper Core Conductor Single Conductor
- Material [MATT]
- Plastic Ethylene-Tetrafluoroethylene 1St Position Primary Insulation Single Conductor
- Material [MATT]
- Silver 1St Position Conductor Single Conductor
- Round Conductor Size [CXDC]
- 28 Awg Single Conductor
- Specification/Standard Data [ZZZK]
- 81349-Mil-W-22759/44 Government Specification
- Strand Awg Size Per Conductor [CXDG]
- 36 Single Conductor
- Strand Quantity Per Conductor [BLNZ]
- 7 Single Conductor
- Test Data Document [TEST]
- 81349-Mil-W-22759 Specification (Includes Engineering Type Bulletins, Brochures,Etc., That Reflect Specification Type Data In Specification Format; Excludes Commercial Catalogs, Industry Directories, And Similar Trade Publications, Reflecting General Type Data On Certain Environmental And Performance Requirements And Test Conditions That Are Shown As "Typical", "Average", "Nominal", Etc.).
NATO Stock Numbers Related to 6145-01-312-2236
Freight Information 6145-01-312-2236
6145-01-312-2236 has freight characteristics managed by Germany.. 6145-01-312-2236 has a variance between NMFC and UFC when transported by rail and the description should be consulted.