6145-00-565-5916

Electrical Power Cable

6145005655916 005655916 MIL-DTL-3432 M3432-02MGE(2/16)0342 MILC3432 C002MGE2-16-0342

Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL. View more Electrical Power Cable

6145-00-565-5916 CABLE,POWER,ELECTRICAL 6145005655916 005655916

Managed by United States
NSN Created on 1 Jan 1963
Data Last Changed
January 2023
NATO Update Count
13
NATO Data Quality
AAGR Style 6 for 6145-00-565-5916 1/1
NSN 6145-00-565-5916 (Identification) 1/1

6145-00-565-5916 Stock and Availability Marketplace 6145-00-565-5916

Need Help?
Request a Quotation from participating marketplace vendors

6145-00-565-5916 Related Documents Related Documents 6145-00-565-5916 5+ Documents (More...)

for $1 a day Upgrade your Account Upgrade 6145-00-060-5430Electrical Wire6145000605430 000605430 MIL-DTL-3432
M3432-01HLF(1/16)0194 C001HLF1-16-0194 MILC3432 A single metallic conductor of solid, stranded,
M3432-02H0E(2/8)0810 MILC3432 C0-02H0E2-8-0810 Two or more insulated conductors (solid or stranded
M3432-01HGF(1/2)0660 C001HGF1-2-0660 MILC3432 A single metallic conductor of solid, stranded, or
M3432-02H0E(2/8)0810 MILC3432 C0-02H0E2-8-0810 Two or more insulated conductors (solid or stranded
Two or more insulated conductors (solid or stranded) M3432-04MGF(4/12)0523 C0-04MGF4-12-052 MILC3432
M3432-04HGE(4/0)JS MILC3432 C0-04HGE4-1-0JS Two or more insulated conductors (solid or stranded
M3432-01HLF(1/16)0194 C001HLF1-16-0194 MILC3432 A single metallic conductor of solid, stranded,
M3432-02H0E(2/8)0810 MILC3432 C0-02H0E2-8-0810 Two or more insulated conductors (solid or stranded
M3432-14MGF(14/22)SJ0500 C014MGF14-22SJ0500 MILC3432 Two or more insulated conductors (solid or
A single metallic conductor of solid, stranded, M3432-02H0E(2/8)0810 MILC3432 C0-02H0E2-8-0810 Two or
M3432-01HLF(1/16)0194 C001HLF1-16-0194 MILC3432 A single metallic conductor of solid, stranded,
day Upgrade your Account Upgrade 6145-00-617-1249Electrical Power Cable6145006171249 006171249 MIL-DTL-3432
M3432-14H0F(14/18)SJ0720 C014H0F14-18SJ0720 MILC3432 Two or more insulated conductors (solid or
M3432-01HLF(1/16)0194 C001HLF1-16-0194 MILC3432 A single metallic conductor of solid, stranded,

6145-00-565-5916 Demil Restrictions 6145-00-565-5916

DEMIL: A | DEMILI: | CRITICALITY: X | HMIC: N | PMIC: U | EDC: | ADPEC:

6145-00-565-5916 is a Electrical Power Cable that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.

6145-00-565-5916 HTS and ScheduleB Import and Export 6145-00-565-5916

6145-00-565-5916 End Users End Users 6145-00-565-5916

Brazil (YA01)
Effective Date:
1 Sep 2000

6145-00-565-5916 Manufacturers Approved Sources 6145-00-565-5916

6145-00-565-5916 Technical Data Datasheet 6145-00-565-5916

Characteristic
Specifications
FIIG
A077A0
Color [HUES]
Black 1St Position Cover First Conductor
Color [HUES]
White 2Nd Position Cover Second Conductor
Conductor Arrangement And Quantity [CXDQ]
2 Singles
Conductor Form [CXCW]
Stranded All Conductors
Cross Section Outside Diameter [ADVL]
0.342 Inches Nominal
Cross-Sectional Shape Style [AAGR]
Round
Conductor Quantity [AMQN]
2
Material Document And Classification [MDCL]
Qq-W-343,Soft Fed Spec Single Material Response Core Conductor All Conductors
Material [MATT]
Copper Core Conductor All Conductors
Material [MATT]
Rubber Butadiene-Styrene Class Sbr 1St Position Jacket Cable
Material [MATT]
Rubber Butadiene-Styrene Class Sbr 1St Position Primary Insulation All Conductors
Round Conductor Size [CXDC]
16 Awg All Conductors
Voltage Rating [CXFK]
600.0 Ac Maximum Rated Working Voltage All Conductors
Strand Awg Size Per Conductor [CXDG]
36 All Conductors
Strand Quantity Per Conductor [BLNZ]
104 All Conductors
Surface Treatment [SFTT]
Tin Core Conductor All Conductors

6145-00-565-5916 Related Items NATO Stock Numbers Related to 6145-00-565-5916

6145-00-565-5916 Freight Data Freight Information 6145-00-565-5916

6145-00-565-5916 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 030310. A Sub NMFC of Z. It has a NMFC Description of CABLE OR WIRE. 6145-00-565-5916 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. 6145-00-565-5916 is rated as class 60 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 15080 which rates the freight between FCL and LCL. 6145-00-565-5916 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 743 for ocean manifesting and military sealift. 6145-00-565-5916 is not classified as a special type of cargo when transported by water. 6145-00-565-5916 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.