Premium Information is available for this item - Upgrade for $1 a day

6145-00-350-0132

Electrical Wire

6145003500132 003500132 MIL-DTL-76 M76LWPC207A902 MILW76 LWC20-7U902

A single metallic conductor of solid, stranded, or tinsel construction, designed to carry current in an electrical circuit. It may be a bare or insulated, may have metalic covering sheath, shield or and additional jacket. Refers to bulk quantities only. For items that are solid or stranded, insulated or uninsulated, and have the chemical composition specified but no conductivity (electrical properties) see WIRE,(as modified), Includes Litz wire and insulated/uninsulated armored, and ground wire. Excludes BRAID, WIRE; FUSE WIRE; RESISTANCE WIRE and MAGNET WIRE. View more Electrical Wire

6145-00-350-0132 WIRE,ELECTRICAL 6145003500132 003500132

Managed by United States
NSN Created on 5 Apr 1971
Data Last Changed
January 2023
NATO Update Count
10
NATO Data Quality
AAGR Style 6 for 6145-00-350-0132 1/1
NSN 6145-00-350-0132 (Identification) 1/1

6145-00-350-0132 Stock and Availability Marketplace 6145-00-350-0132

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
6145-00-350-0132 RQST NE eBay
eBay Updated Every Day
6145-00-350-0132 RQST eBay
Amazon Updated Every Day
6145-00-350-0132 RQST NE Amazon

6145-00-350-0132 Related Documents Related Documents 6145-00-350-0132 5+ Documents (More...)

MIL-DTL-76 M76LWPC207A902 MILW76 LWC20-7U902 A single metallic conductor of solid, stranded, or tinsel
Every Day 6145-00-350-0132 RQST Updated Every Day 6145-00-350-0132 RQST NE Related Documents 6145-00
Marketplace Restrictions Approved Sources Datasheet Management Every Day 6145-00-350-0132 RQST
for $1 a day Upgrade your Account Upgrade 6145-00-763-4430Electrical Wire6145007634430 007634430 MIL-DTL-76
MILW76 A single metallic conductor of solid, stranded, or tinsel construction, designed to carry
4430 RQST NE Related Documents 6145-00 6145-00-763-4430 RQST NE Related Documents 6145-00 HWC22-7B3 MILW76
for $1 a day Upgrade your Account Upgrade 6145-00-548-1755Electrical Wire6145005481755 005481755 MIL-DTL-76
HWC22-7B3 MILW76 A single metallic conductor of solid, stranded, or tinsel construction, designed
https//www.nsnlookup.com /fsg-61/fsc-6145/us 6145-00-635-7828 Electrical Power Cable 6145006357828,MILW76
for $1 a day Upgrade your Account Upgrade 6145-00-539-8941Electrical Wire6145005398941 005398941 MIL-DTL-76
MWC20-1B9 MILW76 A single metallic conductor of solid, stranded, or tinsel construction, designed
MWC22-1B2 A single metallic conductor of solid, stranded, or tinsel construction MWC18-16B6 MILW76 A
for $1 a day Upgrade your Account Upgrade 6145-00-295-0830Electrical Wire6145002950830 002950830 MIL-DTL-76
HWC16-19B9 MILW76 A single metallic conductor of solid, stranded, or tinsel construction, designed
fsg-61/fsc-6145/us 6145-00-975-0911 Electrical Wire 6145009750911 009750911 MWC16-1U0 M76MWPC161A0 MILW76

6145-00-350-0132 Demil Restrictions 6145-00-350-0132

DEMIL: A | DEMILI: | CRITICALITY: X | HMIC: N | PMIC: A | EDC: | ADPEC: 0

6145-00-350-0132 is a Electrical Wire that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.

6145-00-350-0132 HTS and ScheduleB Import and Export 6145-00-350-0132

6145-00-350-0132 End Users End Users 6145-00-350-0132

Austria (WB01)
Effective Date:
1 Feb 2005
Greece (ZU01)
Effective Date:
1 Apr 1991

6145-00-350-0132 Manufacturers Approved Sources 6145-00-350-0132

6145-00-350-0132 Technical Data Datasheet 6145-00-350-0132

Characteristic
Specifications
FIIG
A077A0
Color [HUES]
White 1St Position Cover Single Conductor
Conductor Form [CXCW]
Stranded Single Conductor
Cross Section Outside Diameter [ADVL]
0.065 Inches Nominal
Cross-Sectional Shape Style [AAGR]
Round
Material Document And Classification [MDCL]
Qq-W-343,Soft Fed Spec Single Material Response Core Conductor Single Conductor
Material [MATT]
Copper Core Conductor Single Conductor
Material [MATT]
Plastic Polyvinyl Chloride 1St Position Primary Insulation Single Conductor
Round Conductor Size [CXDC]
20 Awg Single Conductor
Voltage Rating [CXFK]
300.0 Ac Maximum Rated Working Voltage Single Conductor
Strand Awg Size Per Conductor [CXDG]
28 Single Conductor
Strand Quantity Per Conductor [BLNZ]
7 Single Conductor
Surface Treatment [SFTT]
Tin Core Conductor Single Conductor
Temp Rating [ABJH]
80.0 Deg Celsius
Tracer Color [ASGF]
Black First Tracer Single Conductor
Tracer Color [ASGF]
Red Second Tracer Single Conductor

6145-00-350-0132 Similar Items Similar Supply Items to 6145-00-350-0132

6145-00-350-0132 Freight Data Freight Information 6145-00-350-0132

6145-00-350-0132 has freight characteristics managed by the Southwestern Power Administration.It has a National Motor Freight Classification (NMFC) of 030310. A Sub NMFC of Z. It has a NMFC Description of CABLE OR WIRE. 6145-00-350-0132 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. 6145-00-350-0132 is rated as class 60 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 15080 which rates the freight between FCL and LCL. It has a Water Commodity Code (WCC) of 743 for ocean manifesting and military sealift. 6145-00-350-0132 is not classified as a special type of cargo when transported by water. 6145-00-350-0132 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.