Premium Information is available for this item - Upgrade for $1 a day
6145-00-350-0132
Electrical Wire
6145003500132 003500132 MIL-DTL-76 M76LWPC207A902 MILW76 LWC20-7U902
A single metallic conductor of solid, stranded, or tinsel construction, designed to carry current in an electrical circuit. It may be a bare or insulated, may have metalic covering sheath, shield or and additional jacket. Refers to bulk quantities only. For items that are solid or stranded, insulated or uninsulated, and have the chemical composition specified but no conductivity (electrical properties) see WIRE,(as modified), Includes Litz wire and insulated/uninsulated armored, and ground wire. Excludes BRAID, WIRE; FUSE WIRE; RESISTANCE WIRE and MAGNET WIRE. View more Electrical Wire
![]()
January 2023
10

Marketplace 6145-00-350-0132
Request a Quotation from participating marketplace vendors
Related Documents 6145-00-350-0132 5+ Documents (More...)
Every Day 6145-00-350-0132 RQST Updated Every Day 6145-00-350-0132 RQST NE Related Documents 6145-00
Marketplace Restrictions Approved Sources Datasheet Management Every Day 6145-00-350-0132 RQST
MILW76 A single metallic conductor of solid, stranded, or tinsel construction, designed to carry
4430 RQST NE Related Documents 6145-00 6145-00-763-4430 RQST NE Related Documents 6145-00 HWC22-7B3 MILW76
HWC22-7B3 MILW76 A single metallic conductor of solid, stranded, or tinsel construction, designed
https//www.nsnlookup.com /fsg-61/fsc-6145/us 6145-00-635-7828 Electrical Power Cable 6145006357828,MILW76
MWC20-1B9 MILW76 A single metallic conductor of solid, stranded, or tinsel construction, designed
MWC22-1B2 A single metallic conductor of solid, stranded, or tinsel construction MWC18-16B6 MILW76 A
HWC16-19B9 MILW76 A single metallic conductor of solid, stranded, or tinsel construction, designed
fsg-61/fsc-6145/us 6145-00-975-0911 Electrical Wire 6145009750911 009750911 MWC16-1U0 M76MWPC161A0 MILW76
Restrictions 6145-00-350-0132
6145-00-350-0132 is a Electrical Wire that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 6145-00-350-0132
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6145-00-350-0132
- Austria (WB01)
- Effective Date:
- 1 Feb 2005
- Greece (ZU01)
- Effective Date:
- 1 Apr 1991
Approved Sources 6145-00-350-0132
- Part Number
- Manufacturer
- Status
- M76LWPC207A902
- Manufacturer
- 81349 - Military Specifications (Active)
- Definitive Standard
- Definitive Standard
- MIL-DTL-76
- 81349 - Military Specifications (Active)
- Incomplete Standard
- Incomplete Standard
- MILW76
- 81349 - Military Specifications (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- LWC20-7U902
- 81349 - Military Specifications (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 6145-00-350-0132
- Characteristic
- Specifications
- FIIG
- Specifications
- A077A0
- Color [HUES]
- White 1St Position Cover Single Conductor
- Conductor Form [CXCW]
- Stranded Single Conductor
- Cross Section Outside Diameter [ADVL]
- 0.065 Inches Nominal
- Cross-Sectional Shape Style [AAGR]
- Round
- Material Document And Classification [MDCL]
- Qq-W-343,Soft Fed Spec Single Material Response Core Conductor Single Conductor
- Material [MATT]
- Copper Core Conductor Single Conductor
- Material [MATT]
- Plastic Polyvinyl Chloride 1St Position Primary Insulation Single Conductor
- Round Conductor Size [CXDC]
- 20 Awg Single Conductor
- Voltage Rating [CXFK]
- 300.0 Ac Maximum Rated Working Voltage Single Conductor
- Strand Awg Size Per Conductor [CXDG]
- 28 Single Conductor
- Strand Quantity Per Conductor [BLNZ]
- 7 Single Conductor
- Surface Treatment [SFTT]
- Tin Core Conductor Single Conductor
- Temp Rating [ABJH]
- 80.0 Deg Celsius
- Tracer Color [ASGF]
- Black First Tracer Single Conductor
- Tracer Color [ASGF]
- Red Second Tracer Single Conductor
Similar Supply Items to 6145-00-350-0132


















Freight Information 6145-00-350-0132
6145-00-350-0132 has freight characteristics managed by the Southwestern Power Administration.It has a National Motor Freight Classification (NMFC) of 030310. A Sub NMFC of Z. It has a NMFC Description of CABLE OR WIRE. 6145-00-350-0132 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. 6145-00-350-0132 is rated as class 60 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 15080 which rates the freight between FCL and LCL. It has a Water Commodity Code (WCC) of 743 for ocean manifesting and military sealift. 6145-00-350-0132 is not classified as a special type of cargo when transported by water. 6145-00-350-0132 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.