6145-00-160-6192
Electrical Power Cable
6145001606192 001606192 S TIREX2C0NDUCT0RS10AWG S2N010AWG259STRANDSN034
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL. View more Electrical Power Cable
January 2023
13
Marketplace 6145-00-160-6192
Request a Quotation from participating marketplace vendors
Related Documents 6145-00-160-6192 5+ Documents (More...)
X 1 Jan 1963 6145-00-160-3929 Electrical Power Cable WRNCC: 3 | RNVC: 1 | DAC: 4 1 Jan 1963 6145-00-160-6192
Restricted Technical Data Package (TDP):Contains Classified MaterialWeapons System Indicator Code (WSIC):S
Coupling Assembly ULCS-513RNCC: 4 | RNVC: 1 | DAC: 6 6 Jun 1968 4210-21-583-1022 Fire Hose Coupling S-
Jan 1961 5975-00-178-1219 Rigid Metal Conduit ANSI/UL797RNCC: 3 | RNVC: 1 | DAC: 5 1 Jan 1963 6145-00-160-6192
S WIRE,ELECTRICAL RQST NS Request Quotation Subscribe to View Vendor Details...
S WIRE,ELECTRICAL 552 EA NS Request Quotation Subscribe to View Vendor Details...
Restrictions 6145-00-160-6192
6145-00-160-6192 is a Electrical Power Cable that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Import and Export 6145-00-160-6192
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6145-00-160-6192
- Republic of Korea (ZH01)
- Effective Date:
- 1 Apr 1991
- Greece (ZU01)
- Effective Date:
- 1 Apr 1991
Approved Sources 6145-00-160-6192
- Part Number
- Manufacturer
- Status
- S
- Manufacturer
- 88193 - Underwriters Laboratories Inc (Active)
- Incomplete Reference
- Incomplete Reference
- TIREX2C0NDUCT0RS10AWG
- 78310 - Subcom Cable Systems, Llc (Active)
- Primary Buy
- Primary Buy
- S2N010AWG259STRANDSN034
- 81345 - Underwriters Laboratories Inc (Active)
- Primary Buy
- Primary Buy
Datasheet 6145-00-160-6192
- Characteristic
- Specifications
- FIIG
- Specifications
- A077A0
- Conductor Quantity [AMQN]
- 2
- Conductor Form [CXCW]
- Stranded All Conductors
- Material [MATT]
- Copper Core Conductor All Conductors
- Material [MATT]
- Rubber Natural 1St Position Primary Insulation All Conductors
- Material [MATT]
- Cotton 1St Position Braid, Non-Metallic Cable
- Material Document And Classification [MDCL]
- Mil-I-3930,Type Is Mil Spec Single Material Response 1St Position Primary Insulation All Conductors
- Surface Treatment [SFTT]
- Tin Core Conductor All Conductors
- Round Conductor Size [CXDC]
- 10 Awg All Conductors
- Strand Quantity Per Conductor [BLNZ]
- 259 All Conductors
- Strand Awg Size Per Conductor [CXDG]
- 34 All Conductors
- Color [HUES]
- Black 1St Position Cover First Conductor
- Color [HUES]
- White 2Nd Position Cover Second Conductor
- Voltage Rating [CXFK]
- 600.0 Ac Maximum Rated Working Voltage All Conductors
- Cross-Sectional Shape Style [AAGR]
- Round
- Cross Section Outside Diameter [ADVL]
- 0.640 Inches Nominal
NATO Stock Numbers Related to 6145-00-160-6192
Freight Information 6145-00-160-6192
6145-00-160-6192 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 030310. A Sub NMFC of Z. It has a NMFC Description of CABLE OR WIRE. 6145-00-160-6192 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. 6145-00-160-6192 is rated as class 60 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 15080 which rates the freight between FCL and LCL. 6145-00-160-6192 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 743 for ocean manifesting and military sealift. 6145-00-160-6192 is not classified as a special type of cargo when transported by water. 6145-00-160-6192 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.