Premium Information is available for this item - Upgrade for $1 a day
6110-01-417-8928
Electrical System Protection Panel
6110014178928 014178928 1261F88G04
A panel which is specifically designed to provide one or more kinds of protection for any or all equipment used in an electrical system. Protection provided may be such as differential current protection, reverse phase sequence connection protection, over-excitation protection, under-speed protection, over-voltage protection, fault protection, under-voltage protection, surge protection, etc. May control the generator(s) operation. Incorporates into a single item the system protection formerly placed at various points in the electrical system. For panels designed for the protection of power line feeders only, see PANEL, POWER DISTRIBUTION and PANEL, FUSE. For items designed to transfer the load from one power source to an alternate power source, see SWITCHING UNIT, POWER TRANSFER. View more Electrical System Protection Panel
May 2023
1

Marketplace 6110-01-417-8928
Request a Quotation from participating marketplace vendors
Related Documents 6110-01-417-8928 3+ Documents (More...)
United States (US) 4. 6110-01-417-8928 Marketplace Restrictions Approved Sources Datasheet Management
Request a Quotation from participating marketplace vendors Request Updated Every Day 6110-01-417-8928

/fsg-61/fsc-6115/us
Electrical System Protection Panel 014178928 your Account Upgrade 6110-01-417-8928Electrical System
Protection Panel6110014178928 014178928 1261F88G04 Direct Current Generator 6115011936473 day Upgrade
/www.nsnlookup.com /fsg-29/fsc-2920/us 2920-01-469-9905 Electrical Terminal Block 2920014699905 1261F88G04
6115/us 6115-01-193-6473 Direct Current Generator 6115011936473 Electrical System Protection Panel 014178928
Restrictions 6110-01-417-8928
6110-01-417-8928 is a Electrical System Protection Panel that does not have a nuclear hardened feature, but does have another critical feature or features such as tolerance, fit restriction or application. This item is a US Munitions List or Commerce Control List Item where the Item Manager, Equipment Specialist or Product Specialist must provide special demilitarization instructions. This item is not suspected to be hazardous. This item does not contain a precious metal.
Import and Export 6110-01-417-8928
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6110-01-417-8928
- US Navy (N2HD)
- Effective Date:
- 1 Nov 1995
- Former MOE Rule:
- N1HE
- Supplementary Receivers:
- GG
Approved Sources 6110-01-417-8928
- Part Number
- Manufacturer
- Status
- 1261F88G04
- Manufacturer
- 79500 - Westinghouse Electric Corp (Active)
- Incomplete Reference
- Incomplete Reference
Datasheet 6110-01-417-8928
- Characteristic
- Specifications
- FIIG
- Specifications
- A508R0
- Criticality Code Justification [CRTL]
- Zzzy
- Reference Number Differentiating Characteristics [ZZZY]
- Material Will Be In Accordance With Ships Parts Control Center Activity Hx Quality Control, Manufacturing And Testing Specifications
Management Data 6110-01-417-8928
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Oct 2022
- Department of the Navy (DN)
- EA
- Subscribe
- EA
- Oct 2021
- Department of the Navy (DN)
- EA
- Subscribe
- EA
- Oct 2020
- Department of the Navy (DN)
- EA
- Subscribe
- EA
- Apr 2020
- Department of the Navy (DN)
- EA
- Subscribe
- 1
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Navy (DN)
- L
- R
- Refer To Net Price 4395.00
- NET PRICE 4395.00
- R
Navy
- Cognizance:
- 7H
- Special Material ID:
- X3
- Nuclear Reactor Plant (NRP) material under the technical cognizance of the NAVSEA 08 special designed, manufactured and/or treated for use in a NRP or controls thereof. This category includes all other NRP items which are not coded X2 or X4.
- Issue, Repair, Requisition Restriction Code:
- BL
- Submit/refer requisitions to NAVICP MECH. Centralized control for issue of repair parts for specific programs/equipment
- Special Material Content:
- 3
- Electrostatic Discharge (ESD)/Sensitive Item
Similar Supply Items to 6110-01-417-8928


















Freight Information 6110-01-417-8928
6110-01-417-8928 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061700. A Sub NMFC of Z. It has a NMFC Description of ELEC APPLIANCES/INSTRUMENTS NOI. 6110-01-417-8928 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. 6110-01-417-8928 is rated as class 100 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 34580 which rates the freight between FCL and LCL. 6110-01-417-8928 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 6110-01-417-8928 is not classified as a special type of cargo when transported by water. 6110-01-417-8928 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 6110-01-417-8928
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- Packaging Data does not meet current MIL-STD-2073-1E
- Storage Environment
- Unheated General Purpose
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- Over 10lb
- Less than 85G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- No Requirement
- PPP-C-795, Class 2, Antistatic Cellular Plastic Film Cushioning
- 1/2 inch thick
- ASTM-D5118, Type CF, Class Weather-Resistant, Corrugated Fiberboard Box
- ESD sensitive electronic device requirements of MIL-STD-129 apply
- No Requirement
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- --
- No Requirement