Premium Information is available for this item - Upgrade for $1 a day

6110-00-629-7062

Electrical System Protection Panel

6110006297062 006297062 EX34B3-4B 34B3-4B

A panel which is specifically designed to provide one or more kinds of protection for any or all equipment used in an electrical system. Protection provided may be such as differential current protection, reverse phase sequence connection protection, over-excitation protection, under-speed protection, over-voltage protection, fault protection, under-voltage protection, surge protection, etc. May control the generator(s) operation. Incorporates into a single item the system protection formerly placed at various points in the electrical system. For panels designed for the protection of power line feeders only, see PANEL, POWER DISTRIBUTION and PANEL, FUSE. For items designed to transfer the load from one power source to an alternate power source, see SWITCHING UNIT, POWER TRANSFER. View more Electrical System Protection Panel

6110-00-629-7062 PANEL,PROTECTION,ELECTRICAL SYSTEM 6110006297062 006297062

Managed by United States
NSN Created on 1 Jan 1963
Data Last Changed
January 2023
NATO Update Count
19
NATO Data Quality
6110-00-629-7062 PANEL,PROTECTION,ELECTRICAL SYSTEM 6110006297062 006297062 1/1
NSN 6110-00-629-7062 (Generic Image) 1/1

6110-00-629-7062 Stock and Availability Marketplace 6110-00-629-7062

6110-00-629-7062 Related Documents Related Documents 6110-00-629-7062 1+ Documents (More...)

EX34B3-4B 34B3-4B A panel which is specifically designed to provide one or more kinds of protection
... 34B3-4B PANEL,PROTECTION,ELECTRICAL SYSTEM 1 EA NS Request Quotation Updated Every Day 6110-00-629
-7062 RQST NE Updated Every Day 6110-00-629-7062 RQST Updated Every Day 6110-00-629-7062 RQST NE Related

6110-00-629-7062 Demil Restrictions 6110-00-629-7062

DEMIL: A | DEMILI: | CRITICALITY: X | HMIC: N | PMIC: U | EDC: | ADPEC: 0

6110-00-629-7062 is a Electrical System Protection Panel that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.

6110-00-629-7062 HTS and ScheduleB Import and Export 6110-00-629-7062

6110-00-629-7062 End Users End Users 6110-00-629-7062

Italy (ZR01)
Effective Date:
1 Dec 2007
Greece (ZU01)
Effective Date:
1 Apr 1991

6110-00-629-7062 Manufacturers Approved Sources 6110-00-629-7062

6110-00-629-7062 Technical Data Datasheet 6110-00-629-7062

Characteristic
Specifications
FIIG
A508R0
Special Features [FEAT]
Inclosed,Hermetically Sealed,Alum Panel;Major Components Mtd On Panel Bendix Aviation Corp-Red Bank Div,Relay-Overvoltage P/N 1107193,Generator Control P/N 1109017 And Relay-Lockout P/N 1109044;O/A Dim. 3.906 In. H,5.438 In. W,6.094 In. Deep;Rack Mtd,P/N 3438-48

6110-00-629-7062 Similar Items Similar Supply Items to 6110-00-629-7062

6110-00-629-7062 Freight Data Freight Information 6110-00-629-7062

6110-00-629-7062 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061700. A Sub NMFC of Z. It has a NMFC Description of ELEC APPLIANCES/INSTRUMENTS NOI. 6110-00-629-7062 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. 6110-00-629-7062 is rated as class 77.5 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 34580 which rates the freight between FCL and LCL. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 6110-00-629-7062 is not classified as a special type of cargo when transported by water. 6110-00-629-7062 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

6110-00-629-7062 Packaging Data Packaging Data 6110-00-629-7062

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
Packaging Data does not meet current MIL-STD-2073-1E

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
--
--

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
--
--
--
--
--
Any Suitable Process
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
No Requirement
--
--
--
ASTM-D5118, Type CF, Class Weather-Resistant, Corrugated Fiberboard Box
Method 50

Intermediate Pack Level

Quantity of Unit Packs
Container
No Requirement