Premium Information is available for this item - Upgrade for $1 a day
6110-00-186-2542
Power Distribution Panel
6110001862542 001862542 6002607
A panel designed for connecting, disconnecting and protecting power line feeders and/or direct control of specific electric devices such as lights, motors, electronic equipment, and the like. See also FUSE BOX; SWITCH BOX; DISTRIBUTION BOX; and PANEL,POWER BUS,CURCUIT BREAKER. View more Power Distribution Panel
January 2023
3

Marketplace 6110-00-186-2542
Request a Quotation from participating marketplace vendors
Related Documents 6110-00-186-2542 2+ Documents (More...)

/fsg-61/fsc-6110/us
RQST NE Updated Every Day 6110-00-186-2542 RQST Updated Every Day 6110-00-186-2542 RQST NE Related Documents
6110-00-186-2542 2+ Documents ( More... ) https//www.nsnlookup.com /fsg-61/fsc-6110/us 6110-00-186-2542
Power Distribution Panel 6110001862542 day Upgrade your Account Upgrade 6110-00-186-2542Power Distribution
Panel6110001862542 001862542 6002607 https//www.nsnlookup.com /fsg-61/fsc-6110/us 6110-00-186-2542 Power
Restrictions 6110-00-186-2542
IUID Required
6110-00-186-2542 is a Power Distribution Panel that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Import and Export 6110-00-186-2542
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 6110-00-186-2542
- US Navy (N2CM)
- Effective Date:
- 1 Apr 1991
Approved Sources 6110-00-186-2542
- Part Number
- Manufacturer
- Status
- 6002607
- Manufacturer
- 80091 - Naval Facilities Engineering Command (Active)
- Primary Buy
- Primary Buy
Datasheet 6110-00-186-2542
- Characteristic
- Specifications
- FIIG
- Specifications
- T122-G
- Electrical Input Quantity [APNW]
- 1
- Electrical Output Quantity [APNZ]
- 7
- Mounting Method [ADJH]
- Floor
- Nondefinitive Spec/Std Data [ZZZT]
- Ii Type And 1 Class
- Output Frequency Rating [ANSQ]
- 60 Hertz
- Output Voltage Rating [APPA]
- 120.0 Ac Volts Minimum And 208.0 Ac Volts Maximum
- Inclosure Feature [ANPZ]
- Waterproof
- Input Frequency In Hertz [APPY]
- 60.0
- Input Phase [ANPM]
- Three
- Input Voltage Rating [APNX]
- 480.0 Ac Pounds Per Hour With Retaining Chain
- Overall Height [ABKW]
- 40.000 Inches Maximum
- Overall Length [ABHP]
- 72.000 Inches Maximum
- Overall Width [ABMK]
- 36.000 Inches Maximum
- Panel Material [ANJG]
- Aluminum
- Panel Quantity [APCA]
- 1
- Phase [FAAZ]
- Three
- Special Features [FEAT]
- Portable Assembled Unit,650 Lb Max Wt,Liftable By Fork Lift,Consists Of 5 480V Circuits Of 2 3-Pole 225 Amp Circuit Breakers W/Lugs Only,1 3-Pole 30 Amp Circuit Breaker Feeding The Input Side Of A 15Kva 480 Delta,208/120V,3 Phase,Dry Transformer,1 2-Pole 100 Amp And 2 2-Pole 50 Amp Circuit Breakers W/Lugs Only To Be Connected On The 208/120V Side Of The Transformer,2 3-Pole 30 Amp Circuit Breakers Protecting Two Receptacles,Nema Configuration L21-30R And 14 1-Pole 20 Amp Circuit Breakers Of The Ground Fault Type,Ul Approved,Protecting Fourteen Receptacles,Nema Configurations L5-20R,Ground Lug To Accommodate A No. 1 Or 2 Awg Copper Wire,All Circuit Breakers To Conform To Fed Spec W-C-375
Management Data 6110-00-186-2542
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Jul 2012
- Department of the Navy (DN)
- EA
- Subscribe
- 1
- EA
Navy
- Cognizance:
- 2C
- Major construction and civil engineering equipment
Civil Engineer Support Office
- Issue, Repair, Requisition Restriction Code:
- AH
- Submit/refer requisitions to CESO (Civil Engineer Support Office) CBC Port Hueneme
- Special Material Content:
- 9
- Non-Hazardous or Non-Sensitive Item
Similar Supply Items to 6110-00-186-2542


















Freight Information 6110-00-186-2542
6110-00-186-2542 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061300. A Sub NMFC of X. It has a NMFC Description of CIRCUIT BREAKER/SWITCH NOI. 6110-00-186-2542 is rated as class 77.5 when transported by Less-Than Truckload (LTL) freight. 6110-00-186-2542 is rated as class 77.5 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 34410 which rates the freight between FCL and LCL. 6110-00-186-2542 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 658 for ocean manifesting and military sealift. 6110-00-186-2542 is not classified as a special type of cargo when transported by water. 6110-00-186-2542 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 6110-00-186-2542
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- Packaging Data does not meet current MIL-STD-2073-1E
- Storage Environment
- Heated General Purpose – Heated 40 F and above
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- Over 10lb
- Less than 85G
- Special Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- Special Requirement
- Special Requirements – see Specific Instructions or Drawings provided
- Special Requirements. See Specific Instructions or Drawings Provided
- Special Requirements. See Specific Instructions or Drawings Provided
- Special requirement – See specific instructions or drawings provided
- --
- Special Requirements – see Specific Instructions or Drawings provided
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- --
- Special requirement – See specific instructions or drawings provided