Premium Information is available for this item - Upgrade for $1 a day
5990-00-979-8110
Transmitter Synchro
5990009798110 009798110 995987-01
A synchro consisting of a stator and rotor inductively coupled. The electrical output of the stator into a receiver synchro, a control transformer or differential synchro is dependent upon the position of its rotor. Does not include variable resistors, goniometers, variable transformers, or items with dials. View more Transmitter Synchro
May 2023
6

Marketplace 5990-00-979-8110
Request a Quotation from participating marketplace vendors
Related Documents 5990-00-979-8110 3+ Documents (More...)
BUY NE FedMall Updated Every Day 5990-00-979-8110 RQST NE Updated Every Day 5990-00-979-8110 RQST
Updated Every Day 5990-00-979-8110 RQST NE Related Documents 5990-00-979-8110 3+ Documents ( More...
Transmitter Synchro 5990009798110 009798110 $1 a day Upgrade your Account Upgrade 5990-00-979-8110Transmitter
Synchro5990009798110 009798110 995987 www.nsnlookup.com /fsg-59/fsc-5990/us 5990-00-979-8110 Transmitter
Transmitter Synchro 5990009798110 009798110 fsg-59/fsc-5990/us 5990-00-979-8110 Transmitter https
Restrictions 5990-00-979-8110
5990-00-979-8110 is a Transmitter Synchro that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item is not suspected to be hazardous. The precious metals content of this item is unknown.
Import and Export 5990-00-979-8110
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5990-00-979-8110
- US Air Force (FXGX)
- Effective Date:
- 1 Apr 2006
- Former MOE Rule:
- FXTX
Approved Sources 5990-00-979-8110
- Part Number
- Manufacturer
- Status
- 995987-01
- Manufacturer
- 35351 - Ge Aviation Systems Llc (Active)
- Primary Buy
- Primary Buy
Datasheet 5990-00-979-8110
- Characteristic
- Specifications
- FIIG
- Specifications
- A07800
- Body Size [AJSL]
- 15
- Rotor Input Voltage Rating In Volts [AJSR]
- 26.0 Nominal
- Rotor Input Current Rating [AJST]
- 65.0 Milliamperes Nominal
- Rotor Input Electrical Power Rating [AJSV]
- 33.0 Milliwatts Nominal
- Frequency In Hertz [AJSS]
- 400.0 Nominal
- Rotor Dc Resistance In Ohms [AJTS]
- 42.00 Nominal
- Stator Dc Resistance In Ohms [AJTT]
- 10.80 Nominal
- Maximum Total Null Voltage Output In Millivolts Per Volt [AJVH]
- 40.00
- Actuator Friction Torque At Plus 25 Deg Celsius [AJVT]
- 3.0 Centimeter-Grams Maximum
- Body Style [AAQL]
- Standard Round C
- Shoulder Diameter [AAVH]
- 1.3118 Inches Nominal
- Pilot Diameter [AAVL]
- 0.4998 Inches Nominal
- Overall Length [ABHP]
- 2.1310 Inches Nominal
- Flange Diameter [ABKK]
- 1.4365 Inches Nominal
- Flange Thickness [ABKU]
- 0.0930 Inches Nominal
- Undercut Diameter [ABPA]
- 1.3147 Inches Nominal
- Undercut Width [ABPC]
- 0.0780 Inches Nominal
- Pilot Length [AJWQ]
- 0.0400 Inches Nominal
- Shoulder Length [AJWR]
- 0.1320 Inches Nominal
- Mounting Surface To Terminal End Distance [AJWX]
- 1.1560 Inches Nominal
- Shaft Type [CRSJ]
- Round, Slotted Single Shaft
- Shaft Diameter [ABWV]
- 0.1198 Inches Nominal Single Shaft
- Shaft Length [ABXF]
- 0.5400 Inches Nominal Single Shaft
- Shaft Slot Depth [CQZS]
- 0.0270 Inches Nominal Single Shaft
- Shaft Slot Width [CRHN]
- 0.0270 Inches Nominal Single Shaft
- Terminal Type And Quantity [TTQY]
- 7 Screw
- Terminal Location [CQTM]
- Rear
- Body Material [AAFZ]
- Aluminum
- Fragility Factor [AFJN]
- Moderately Rugged
Weapon Systems (WSDC) 5990-00-979-8110
DLA Procurement Analysis 5990-00-979-8110
Management Data 5990-00-979-8110
Air Force
- Fund:
- SF
- Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point
- Budget:
- 9
- 57X4921.070 - General Support DIV - Air Force decentralized managed expense items (ERRC XB3, XF3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors
- Aggregation Code:
- EH
- ELECTRONIC COMPONENTS
- Price Validation Code:
- N
- The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
The price has not been analyzed or reviewed for accuracy.
ZOP or Standard price challenges are permissible but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of āLā or āFā, then it must be evaluated locally where purchased or fabricated.
- Expendability
Recoverability
Repairability: - N
- Expendable. Condemn at User. Stock Fund (except Munitions).
NATO Stock Numbers Related to 5990-00-979-8110
Freight Information 5990-00-979-8110
5990-00-979-8110 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 062820. A Sub NMFC of Z. It has a NMFC Description of RADIO/TV TRANSMIT/RECEIVE SETS. 5990-00-979-8110 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 35080 which rates the freight between FCL and LCL. 5990-00-979-8110 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 593 for ocean manifesting and military sealift. 5990-00-979-8110 is not classified as a special type of cargo when transported by water. 5990-00-979-8110 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5990-00-979-8110
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- --
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- Electrical Instrument
- 0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
- 85 to 110G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- --
- --
- --
- --
- Any Suitable Process
- --
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- No Requirement
- No Requirement
- PPP-C-795, Cellular Plastic Film Cushioning; or A-A-3129, Open Cell Plastic Cushioning; or PPP-C-1797, Polypropylene Foam Cushioning; or A-A-59136, Polyethylene Foam Cushioning
- --
- PPP-B-566, PPP-B-676, or ASTM-D5118, Folding, Setup or Fiberboard Box
- Method 50
- No Requirement
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- Any Suitable Fiber Box
Contracting Technical Data File (CTDF) 5990-00-979-8110 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- T
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- Y
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: