Premium Information is available for this item - Upgrade for $1 a day

5985-01-644-2004

Electrical Dummy Load

5985016442004 016442004 82-01-19

A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL. View more Electrical Dummy Load

5985-01-644-2004 DUMMY LOAD,ELECTRICAL 5985016442004 016442004

Managed by United States
NSN Created on 24 Apr 2015
Data Last Changed
January 2023
NATO Update Count
2
NATO Data Quality
5985-01-644-2004 DUMMY LOAD,ELECTRICAL 5985016442004 016442004 1/1
NSN 5985-01-644-2004 (Generic Image) 1/1

5985-01-644-2004 Stock and Availability Marketplace 5985-01-644-2004

Need Help?
Request a Quotation from participating marketplace vendors
eBay Updated Every Day
5985-01-644-2004 RQST NE eBay
eBay Updated Every Day
5985-01-644-2004 RQST eBay
Amazon Updated Every Day
5985-01-644-2004 RQST NE Amazon

5985-01-644-2004 Related Documents Related Documents 5985-01-644-2004 1+ Documents (More...)

5985-01-644-2004 1+ Documents ( More... ) https//www.nsnlookup.com /fsg-59/fsc-5985/us 5985-01-644-2004
/fsg-59/fsc-5985/us 5985-01-644-2004 /fsg-59/fsc-5985/us 5985-01-644-2004 /fsg-59/fsc-5985/us 5985-01
-644-2004 /fsg-59/fsc-5985/us 5985-01 -644-2004 /fsg-59/fsc-5985/us 5985-01 -644-2004 Every Day 5985-

5985-01-644-2004 Demil Restrictions 5985-01-644-2004

DEMIL: A | DEMILI: 1 | CRITICALITY: X | HMIC: P | PMIC: A | EDC: | ADPEC: 0

5985-01-644-2004 is a Electrical Dummy Load that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.

5985-01-644-2004 HTS and ScheduleB Import and Export 5985-01-644-2004

5985-01-644-2004 End Users End Users 5985-01-644-2004

Canada (ZC01)
Effective Date:
1 Apr 2015

5985-01-644-2004 Manufacturers Approved Sources 5985-01-644-2004

5985-01-644-2004 Technical Data Datasheet 5985-01-644-2004

Characteristic
Specifications
FIIG
A19800
Connector End Design [AHUD]
Neuter
Cooling Method [BFMF]
Self-Cooled
Frequency Range Rating [AFGQ]
+5.0 To 960.0 Megahertz
Power Rating [AJDB]
250.0 Watts Peak
Overall Height [ABKW]
7.4 Inches Nominal
Overall Width [ABMK]
8.0 Inches Nominal
Part Name Assigned By Controlling Agency [CXCY]
250Watt Precision Air Cooled Rf Load