Premium Information is available for this item - Upgrade for $1 a day
5985-01-576-3227
Variable Attenuator
5985015763227 015763227 3200-1-1
A device for reducing the strength of an alternating current signal either continuously or in steps, without causing appreciable signal distortion, by maintaining substantially constant output and/or input impedance match. Continuously variable resistive devices must consist of at least two sections or one section with at least two rotating contacts. The item must have an overall attenuation rating. Includes tandem mounted variable resistors designed to function as an attenuator but whose terminals are not connected. See also RESISTOR, VAIABLE (as modified). View more Variable Attenuator
January 2023
3
Marketplace 5985-01-576-3227
Request a Quotation from participating marketplace vendors
Related Documents 5985-01-576-3227 2+ Documents (More...)
/fsg-30/fsc-3040/us
Restrictions 5985-01-576-3227
5985-01-576-3227 is a Variable Attenuator that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item has been confirmed as a Critical Munitions List Item or a Sensitive Commerce Control List Item and cannot be in the possession of any party anywhere in the World who is not an authorized NATO Government. Any other possessor of this item should mutilate it now as possession violates international and local laws. This item is a US Munitions List Item and must be mutilated to scrap. This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 5985-01-576-3227
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5985-01-576-3227
- Spain (YB01)
- Effective Date:
- 1 Jul 2009
Approved Sources 5985-01-576-3227
- Part Number
- Manufacturer
- Status
- 3200-1-1
- Manufacturer
- 93459 - Spectrum Control Inc (Active)
- Primary Buy
- Primary Buy
Datasheet 5985-01-576-3227
- Characteristic
- Specifications
- FIIG
- Specifications
- A223A0
- Attenuation Variation Method [ASYF]
- Stepped
- Body Material [AAFZ]
- Aluminum
- Body Style [AAQL]
- Irregular
- Center To Center Distance Between Mounting Facilities Parallel To Width [ABKR]
- 19.0 Millimeters Nominal
- Center To Center Distance Between Mounting Facilities Parallel To Length [ABKQ]
- 88.9 Millimeters Minimum And 95.2 Millimeters Maximum
- Coaxial Connector Series Designation [AHUC]
- Sma
- Frequency Range [BNGR]
- 0.000 Hertz Minimum And 2.000 Gigahertz Maximum
- Application Design [AAFS]
- Transmission Line
- Mounting Facility Nominal Screw Thread Diameter [CRYY]
- 0.112 Inches
- Mounting Facility Screw Thread Series Designator [AKEJ]
- Unc
- Mounting Facility Type And Quantity [AXHR]
- 6 Threaded Hole
- Mounting Thread Quantity [CGGK]
- 40 Per Inch
- Mounting Thread Tolerance Class [CWMS]
- 2B Internal
- Operating Temp Range [AFGA]
- -55.0/+71.0 Deg Celsius
- Impedance Rating In Ohms [CTGG]
- 50.0 Input-Output
- Insertion Loss At Minimum Attenuation In Maximum Decibels [ASYC]
- 4.75
- Power Rating [AJDB]
- 1.0 Watts Average
- Overall Attenuation Range In Decibels [ASYD]
- +0.0/+2.0
- Overall Height [ABKW]
- 25.4 Millimeters Nominal
- Overall Length [ABHP]
- 101.6 Millimeters Nominal
- Overall Width [ABMK]
- 22.8 Millimeters Nominal
- Part Name Assigned By Controlling Agency [CXCY]
- 3200 Series Programmable Step Attenuator
- Special Features [FEAT]
- Total Attenuation For Steps Is 127Db Starting W/1 And Doubling To 64; Connectors: Stainless Steel Body And Beryllium Copper Contacts, Control Terminals: Brass/Copper, Silver Plated
- Voltage Standing Wave Ratio [AHTW]
- 1.30 And 1.35
- Step Position Quantity [ASYG]
- 8
- Terminal Type And Quantity [TTQY]
- 2 Connector, Coaxial, Female And 7 Solder Stud
NATO Stock Numbers Related to 5985-01-576-3227
Freight Information 5985-01-576-3227
5985-01-576-3227 has freight characteristics.. 5985-01-576-3227 has a variance between NMFC and UFC when transported by rail and the description should be consulted.