An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE. View more Waveguide Assembly
![]()
May 2023
3


Marketplace 5985-01-099-5959
Request a Quotation from participating marketplace vendors
Related Documents 5985-01-099-5959 1+ Documents (More...)
(Identification) 1/2 NSN 5985-01-099-5959 (Identification) 2/2 - - 1.
United States (US) 4. 5985-01-099-5959 Marketplace Restrictions Approved Sources Datasheet Management
Restrictions 5985-01-099-5959
5985-01-099-5959 is a Waveguide Assembly The DCMO has forced the Demilization requirements for this item as the ICP has not collaborated. This item is a US Munitions List or Commerce Control List Item which must be destroyed to prevent restoration or repair. Only authorized parties may possess this item. This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.
Import and Export 5985-01-099-5959
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5985-01-099-5959
- US Army (A503)
- Effective Date:
- 1 Apr 1991
Approved Sources 5985-01-099-5959
- Part Number
- Manufacturer
- Status
- SM-D-952437-1
- Manufacturer
- 80063 - Us Army Communications & Electronics (Active)
- Primary Buy
- Primary Buy
Datasheet 5985-01-099-5959
- Characteristic
- Specifications
- FIIG
- Specifications
- A073A0
- Cross-Sectional Shape Style [AAGR]
- Internal, Rectangular External, Rectangular
- Flange Connecting Hole Diameter [AHTN]
- 0.192 Inches Minimum Second Flange Single Connection Facility And 0.200 Inches Maximum Second Flange Single Connection Facility
- Flange Depth [AHTD]
- 0.480 Inches Minimum Second Flange And 0.520 Inches Maximum Second Flange
- Flange Depth [AHTD]
- 0.735 Inches Minimum First Flange And 0.765 Inches Maximum First Flange
- Flange Connecting Facility And Quantity [CSQT]
- 6 Threaded Hole First Flange Single Connection Facility
- Flange Connecting Facility And Quantity [CSQT]
- 8 Unthreaded Hole Second Flange Single Connection Facility
- Flange Inside Height [AHSY]
- 0.618 Inches Minimum First Flange And 0.626 Inches Maximum First Flange
- Flange Inside Height [AHSY]
- 0.618 Inches Minimum Second Flange And 0.626 Inches Maximum Second Flange
- Flange Inside Width [AHSX]
- 1.368 Inches Minimum Second Flange And 1.376 Inches Maximum Second Flange
- Flange Inside Width [AHSX]
- 1.368 Inches Minimum First Flange And 1.376 Inches Maximum First Flange
- Flange Quantity [AHSF]
- 2
- Flange Style [CTCJ]
- Choke Type First Flange
- Flange Style [CTCJ]
- Contact Type Second Flange
- Flange Outside Diameter [AHTC]
- 3.110 Inches Minimum First Flange And 3.140 Inches Maximum First Flange
- Flange Outside Height [AHTA]
- 1.920 Inches Minimum Second Flange And 1.960 Inches Maximum Second Flange
- Flange Outside Width [AHSZ]
- 2.670 Inches Minimum Second Flange And 2.710 Inches Maximum Second Flange
- Flexibility [FLEX]
- Rigid Single Tubing Segment
- Material [MATT]
- Copper Alloy All Tubing Segment And Flange
- Maximum Operating Pressure [CQGM]
- 10.0 Pounds Per Square Inch Gage
- Nominal Thread Size [CQJX]
- 0.190 Inches First Flange Single Connection Facility
- Style Designator [STYL]
- Offset Bend Type
- Tubing Wall Construction Style [AHRV]
- Seamless Single Tubing Segment
- Voltage Standing Wave Ratio [AHTW]
- 1.10
- Waveguide Inside Height [CRLB]
- 0.618 Inches Minimum And 0.626 Inches Maximum
- Waveguide Inside Width [CRFH]
- 1.368 Inches Minimum And 1.376 Inches Maximum
- Waveguide Length [CTFD]
- 18.100 Inches Minimum And 18.140 Inches Maximum
- Waveguide Center To Center Distance [CXBB]
- 2.730 Inches Minimum And 2.770 Inches Maximum
- Waveguide Outside Height [CSFC]
- 0.746 Inches Minimum And 0.754 Inches Maximum
- Waveguide Outside Width [CQHN]
- 1.496 Inches Minimum And 1.504 Inches Maximum
- Surface Treatment [SFTT]
- Paint All Tubing Segment And Flange Outside Surfaces
- Thread Class [AAJD]
- 2B First Flange Single Connection Facility
- Thread Direction [AAJF]
- Right-Hand First Flange Single Connection Facility
- Thread Series Designator [THSD]
- Unf First Flange Single Connection Facility
Management Data 5985-01-099-5959
Army
- Materiel Category and Inventory Manager:
- G
- Communications and Electronics Equipment, Electronics Materiel
- Appropriation and Budget Activity:
- 2
- Stock Fund Secondary Items
- Management Inventory Segment:
- 3
- Insurance Items
This code will identify items for which there may be occasional intermittent demands not sufficiently repetitive to warrant classification as regular stock items, but for which prudence requires that nominal quantity be stocked for the reason that the essentiality of the item and the long lead time required to obtain such items by purchase would create an unacceptable situation if no stock were carried.
- Weapons System / End Item / Homogeneous Group:
- 4A
- Communications System Agency and Satellite Communications Agency Equipment
Defense Satellite Communications System (DSCS) Terminals AN/FSC-78/79
- Accounting Requirements:
- X
- Expendable item.An item of Army property coded with an ARC of X in the AMDF. Expendable items require no formal accountability after issue from a stock record account.Commercial and fabricated items similar to items coded X in the AMDF are considered expendable items.
Similar Supply Items to 5985-01-099-5959


















Freight Information 5985-01-099-5959
5985-01-099-5959 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 063520. A Sub NMFC of Z. It has a NMFC Description of WAVEGUIDE IN BOXES/CRATES. 5985-01-099-5959 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. 5985-01-099-5959 is rated as class 77.5 when transported by Less-Than Carload (LCL) rail or ocean freight. It has a Uniform Freight Classification (UFC) number of 49770 which rates the freight between FCL and LCL. It has a Water Commodity Code (WCC) of 723 for ocean manifesting and military sealift. 5985-01-099-5959 is not classified as a special type of cargo when transported by water. 5985-01-099-5959 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Packaging Data 5985-01-099-5959
- Responsible Activity
- Packaging Data Source
- Primary Inventory Control Activity (PICA)
- Packaging Data does not meet current MIL-STD-2073-1E
- Storage Environment
- Heated General Purpose – Heated 40 F and above
Item Pack Level (Unpackaged)
- Item Size
- Item Weight
- Characteristics
- Weight/Dimensions Category
- Fragility
- Item Preservation
- Item Weight
- --
- --
- --
- Over 10lb
- Less than 85G
- No Requirement
- --
Unit Pack Level (Packaged)
- Quantity per Pack
- Unit Size
- Unit Weight
- Unit Cube
- Preservation Method
- Cleaning/Drying
- Unit Size
- 1
- 18.6" H x 5.2" W x 3.6" L
- --
- --
- --
- Special Requirements
- 18.6" H x 5.2" W x 3.6" L
- Preservation Material
- Wrapping Material
- Cushioning/Dunnage
- Cushioning Thickness
- Container
- Special Marking
- Wrapping Material
- Special Requirement
- Special Requirements – see Specific Instructions or Drawings provided
- Special Requirements. See Specific Instructions or Drawings Provided
- Special Requirements. See Specific Instructions or Drawings Provided
- Special requirement – See specific instructions or drawings provided
- --
- Special Requirements – see Specific Instructions or Drawings provided
Intermediate Pack Level
- Quantity of Unit Packs
- Container
- --