Premium Information is available for this item - Upgrade for $1 a day

5985-00-570-0074

Waveguide Assembly

5985005700074 005700074 2536121

An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE. View more Waveguide Assembly

5985-00-570-0074 WAVEGUIDE ASSEMBLY 5985005700074 005700074

Managed by United States
NSN Created on 1 Dec 1974
Data Last Changed
May 2023
NATO Update Count
6
NATO Data Quality
AAGR Style A1 for 5985-00-570-0074 1/2
NSN 5985-00-570-0074 (Identification) 1/2
STYL Style B5 for 5985-00-570-0074 2/2
NSN 5985-00-570-0074 (Identification) 2/2

5985-00-570-0074 Stock and Availability Marketplace 5985-00-570-0074

Need Help?
Request a Quotation from participating marketplace vendors

5985-00-570-0074 Related Documents Related Documents 5985-00-570-0074 5+ Documents (More...)

to enable JavaScript in your web browser . 9520-25-143-9704Montering Skinne9520251439704 251439704 2536121
-143-9704 Norway (ZT) Approved Sources 9520-25- https//www.nsnlookup.com /fsg-59/fsc-5985/us 5985-00-570-0074
Waveguide Assembly 5985005700074 005700074 for $1 a day Upgrade your Account Upgrade 5985-00-570
4730-12-315-5441 4730123155441 123155441 is a fluid line fitting having a pipe, tube or hose connection or a through hole to accommodate a bolt, fluid passage on one end. the other end must have an internal or external quick disconnect feature for connecting a mating part to form a quick disconnect coupling assembly. the fitting may incorporate a self-sealing feature for the purpose of automatically shutting off the flow of fluid when disconnected from its mating half. for self-sealing fittings with an external or internal threaded disconnect end, see coupling half, self-sealing. see also, connector, multiple, fluid pressure line.

5985-00-570-0074 Demil Restrictions 5985-00-570-0074

DEMIL: D | DEMILI: | CRITICALITY: X | HMIC: P | PMIC: A | EDC: | ADPEC: 0

5985-00-570-0074 is a Waveguide Assembly that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is a US Munitions List or Commerce Control List Item which must be destroyed to prevent restoration or repair. Only authorized parties may possess this item. This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. This item does not contain a precious metal.

5985-00-570-0074 HTS and ScheduleB Import and Export 5985-00-570-0074

5985-00-570-0074 End Users End Users 5985-00-570-0074

US Navy (N9BN)
Effective Date:
1 Apr 2006
Former MOE Rule:
N9ND
Supplementary Collaborators:
HD

5985-00-570-0074 Manufacturers Approved Sources 5985-00-570-0074

5985-00-570-0074 Technical Data Datasheet 5985-00-570-0074

Characteristic
Specifications
FIIG
A073A0
Bend Angle In Deg [ACJL]
30.0 First Bend E-Plane
Bend Angle In Deg [ACJL]
90.0 Second Bend H-Plane
Cross-Sectional Shape Style [AAGR]
Internal, Rectangular External, Rectangular
Flange Connecting Facility And Quantity [CSQT]
4 Threaded Hole First Flange Single Connection Facility
Flange Connecting Facility And Quantity [CSQT]
4 Unthreaded Hole Second Flange Single Connection Facility
Flange Connecting Hole Diameter [AHTN]
0.169 Inches Minimum Second Flange Single Connection Facility And 0.172 Inches Maximum Second Flange Single Connection Facility
Flange Inside Diameter [AHTB]
1.348 Inches Minimum First Flange And 1.356 Inches Maximum First Flange
Flange Inside Height [AHSY]
0.493 Inches Minimum First Flange And 0.501 Inches Maximum First Flange
Flange Inside Height [AHSY]
0.628 Inches Minimum Second Flange And 0.631 Inches Maximum Second Flange
Flange Depth [AHTD]
0.422 Inches Minimum Second Flange And 0.453 Inches Maximum Second Flange
Flange Depth [AHTD]
1.348 Inches Minimum First Flange And 1.356 Inches Maximum First Flange
Flange Inside Width [AHSX]
1.118 Inches Minimum First Flange And 1.126 Inches Maximum First Flange
Flange Inside Width [AHSX]
1.253 Inches Minimum Second Flange And 1.256 Inches Maximum Second Flange
Flange Outside Height [AHTA]
1.860 Inches Minimum Second Flange And 1.890 Inches Maximum Second Flange
Flange Outside Height [AHTA]
1.860 Inches Minimum First Flange And 1.890 Inches Maximum First Flange
Flange Outside Width [AHSZ]
1.860 Inches Minimum Second Flange And 1.890 Inches Maximum Second Flange
Flange Outside Width [AHSZ]
1.860 Inches Minimum First Flange And 1.890 Inches Maximum First Flange
Flange Quantity [AHSF]
2
Flange Style [CTCJ]
Choke Type First Flange
Flange Style [CTCJ]
Contact Type Second Flange
Flexibility [FLEX]
Rigid Single Tubing Segment
Material [MATT]
Copper Alloy Single Tubing Segment
Maximum Operating Pressure [CQGM]
10.0 Pounds Per Square Inch Gage
Nominal Thread Size [CQJX]
0.164 Inches First Flange Single Connection Facility
Style Designator [STYL]
Double Bend Type
Insertion Loss In Decibels [AHTX]
0.10
Tubing Wall Construction Style [AHRV]
Seamless Single Tubing Segment
Voltage Standing Wave Ratio [AHTW]
2.00
Waveguide Center To Center Distance [CXBB]
16.750 Inches Minimum And 16.812 Inches Maximum
Waveguide Height [CXBD]
8.797 Inches Minimum And 8.827 Inches Maximum
Waveguide Inside Height [CRLB]
0.493 Inches Minimum And 0.501 Inches Maximum
Waveguide Inside Width [CRFH]
1.118 Inches Minimum And 1.126 Inches Maximum
Waveguide Outside Height [CSFC]
0.621 Inches Minimum And 0.629 Inches Maximum
Waveguide Outside Width [CQHN]
1.246 Inches Minimum And 1.254 Inches Maximum
Surface Treatment [SFTT]
Copper All Tubing Segment And Flange Inside Surfaces
Surface Treatment [SFTT]
Oxide Film All Tubing Segment And Flange Outside Surfaces
Thread Class [AAJD]
2B First Flange Single Connection Facility
Thread Direction [AAJF]
Right-Hand First Flange Single Connection Facility
Thread Series Designator [THSD]
Unc First Flange Single Connection Facility

5985-00-570-0074 Weapon Systems (WSDC) Weapon Systems (WSDC) 5985-00-570-0074

5985-00-570-0074 Stock, Inventory and Procurement DLA Procurement Analysis 5985-00-570-0074

DLA Administrative Lead Time:
Subscribe
DLA Production Lead Time:
Subscribe
Subscribe to View DLA Inventory and Forecast...

5985-00-570-0074 Management Data Management Data 5985-00-570-0074

Effective Date
Organization
Unit of Issue
Unit Price
Qty Unit Pack
Oct 2022
Department of the Navy (DN)
EA
Subscribe
1
Oct 2021
Department of the Navy (DN)
EA
Subscribe
1
Oct 2020
Department of the Navy (DN)
EA
Subscribe
1
Mar 2020
Department of the Navy (DN)
EA
Subscribe
1

Navy Navy

Cognizance:
9B
Navy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg

5985-00-570-0074 Related Items NATO Stock Numbers Related to 5985-00-570-0074

5985-00-570-0074 Freight Data Freight Information 5985-00-570-0074

5985-00-570-0074 has freight characteristics managed by the Food and Drug Administration (FDA).It has a National Motor Freight Classification (NMFC) of 063520. A Sub NMFC of Z. It has a NMFC Description of WAVEGUIDE IN BOXES/CRATES. 5985-00-570-0074 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 49770 which rates the freight between FCL and LCL. 5985-00-570-0074 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 723 for ocean manifesting and military sealift. 5985-00-570-0074 is not classified as a special type of cargo when transported by water. 5985-00-570-0074 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.

5985-00-570-0074 Packaging Data Packaging Data 5985-00-570-0074

Responsible Activity
Packaging Data Source
Primary Inventory Control Activity (PICA)
--

Item Pack Level (Unpackaged)

Item Size
Item Weight
Characteristics
Weight/Dimensions Category
Fragility
Item Preservation
--
--
--
0.25 lb or less, one dimension 2" or less, other dimensions less than 24"
85 to 110G
Special Requirement

Unit Pack Level (Packaged)

Quantity per Pack
Unit Size
Unit Weight
Unit Cube
Preservation Method
Cleaning/Drying
1
--
--
--
--
--
Preservation Material
Wrapping Material
Cushioning/Dunnage
Cushioning Thickness
Container
Special Marking
--
--
--
--
--
No special marking

Intermediate Pack Level

Quantity of Unit Packs
Container
See Method of Preservation
--

5985-00-570-0074 Contracting Technical Data File (CTDF) Contracting Technical Data File (CTDF) 5985-00-570-0074 October 2021

Criticality and Quality

Critical Item Code:
Flight Safety:
Life Support:
Certified Samples:
Serialization:
First Article Test (FAT):
Certificate of Quality Compliance:
Production Lot Testing:
Special Testing:
Qualified Products List (QPL):

Commercial Properties

Government Furnished Material:
Government Furnished Tooling:
Government Furnished Property:
Price Evaluation Code:
Diminshing Manufacturing Sources:
Warranty:
Commerical Off The Shelf (COTS):
End Item Application:
Auctioning Candidate:
Source of Procurement:
Contract Option:

Restrictions

Boeing Rights Guard:
Export Controlled:
Controlled Technical Data Package (TDP):
Restricted Technical Data Package (TDP):
Contains Classified Material
Weapons System Indicator Code (WSIC):
F

Packaging Requirements

Packaging Determination Table:
Packaging Review Code:
Special Packaging Instruction Number (SPIN):
Special Packaging Instruction Number Revision:
Special Packaging Instruction Number Date:
Pallet Reference Number Required: