Premium Information is available for this item - Upgrade for $1 a day
5975-00-280-9510
Electrical Box Connector
5975002809510 002809510 AN3062-3 21-19-3 6026-1045-10 6005-1514-33 6026-4210-14
An item designed to mechanically connect in a straight line or an angle electrical conduit, conduit assemblies, wire, wireway, cable, or cable assemblies to a point of termination, such as a junction box, conduit outlet, or the like. The termination end must have an external thread with a boss or shoulder and may be furnished with a locknut or bondnut; or, must have internal thread with which is furnished an externally threaded hub with a wrenching feature; or be of a snap-in type that may be installed from either inside or outside the box and secured with a captive screw. It is not intended to join conduit to conduit. For angle type items having a male thread without a boss or shoulder, see ELBOW, ELECTRICAL CONDUIT. Does not include facilities to mount wiring devices. Excludes CHASE NIPPLE, CONDUIT. View more Electrical Box Connector
January 2023
12
Marketplace 5975-00-280-9510
Request a Quotation from participating marketplace vendors
Related Documents 5975-00-280-9510 2+ Documents (More...)
Electrical Box Connector 5975002809510 Account Upgrade 5975-00-280-9510Electrical Box Connector5975002809510
002809510 AN3062-3 21-19-3 6026-1045-10 RNVC 1 DAC 5 21-19-3 08484 - Breeze-Eastern Llc (Active) Canceled
Restrictions 5975-00-280-9510
5975-00-280-9510 is a Electrical Box Connector that does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. This item is considered a low risk when released from the control of the Department of Defense. The item may still be subject to the requirements of the Export Administration Regulations (EAR) and the Code of Federal Regulations (CFR). This item may be hazardous as it is in a Federal Supply Class for potentially hazardous items. A MSDS should be available from the supplier for the end user to evaluate any hazards. The precious metals content of this item is unknown.
Import and Export 5975-00-280-9510
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5975-00-280-9510
- Canada (ZC01)
- Effective Date:
- 1 Apr 1991
Approved Sources 5975-00-280-9510
- Part Number
- Manufacturer
- Status
- AN3062-3
- Manufacturer
- 88044 - Aeronautical Standards Group (Active)
- Definitive Standard
- Definitive Standard
- 21-19-3
- 30463 - Dcx-Chol Enterprises, Inc. (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- 21-19-3
- 08484 - Breeze-Eastern Llc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 6026-1045-10
- 36378 - Raytheon Technical Services Company (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- 6005-1514-33
- 36378 - Raytheon Technical Services Company (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
- 6026-4210-14
- 36378 - Raytheon Technical Services Company (Replaced)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5975-00-280-9510
- Characteristic
- Specifications
- FIIG
- Specifications
- A01800
- Conduit Type Accommodated [AELS]
- Flexible Metallic First End
- Deflection Angle [ABEX]
- 90.0 Degrees
- End Type [APTD]
- External Thread Second End
- End Type [APTD]
- External Thread First End
- Material [MATT]
- Aluminum Alloy
- Nominal Thread Size [CQJX]
- 0.500 Inches First End
- Nominal Thread Size [CQJX]
- 0.500 Inches Second End
- Leg End To Plane Of Bend Distance [CQMQ]
- 0.812 Inches Nominal Second End
- Leg End To Plane Of Bend Distance [CQMQ]
- 1.125 Inches Nominal First End
- Style Designator [STYL]
- Angle
- Surface Treatment [SFTT]
- Cadmium
- Thread Class [AAJD]
- 2A First End
- Thread Class [AAJD]
- 2A Second End
- Thread Length [AASA]
- 0.313 Inches Nominal Second End
- Thread Series Designator [THSD]
- Unef First End
- Thread Series Designator [THSD]
- Unef Second End
NATO Stock Numbers Related to 5975-00-280-9510
Freight Information 5975-00-280-9510
5975-00-280-9510 has freight characteristics.. 5975-00-280-9510 has a variance between NMFC and UFC when transported by rail and the description should be consulted.