Premium Information is available for this item - Upgrade for $1 a day
5962-01-374-0034
Linear Microcircuit
5962013740034 013740034 NH636213-03 M38510/10104BGA 364A3103P4 364A3103PA 636213-03
A microcircuit whose output is a function of the input; that is, the output varies in a predetermined and essentially predictable manner from the input signal. View more Linear Microcircuit
![]()
May 2023
8

Marketplace 5962-01-374-0034
Request a Quotation from participating marketplace vendors
Related Documents 5962-01-374-0034 5+ Documents (More...)
M38510/10104BGA MICROCIRCUIT,LINEAR 1 EA NS Request Quotation Subscribe to View Vendor Details...
M38510/10104BGA MICROCIRCUIT,LINEAR 32 EA NS Request Quotation Subscribe to View Vendor Details...
M38510/10104BGA MICROCIRCUIT,LINEAR 32 EA NS Request Quotation JM38510/10104BGB MICROCIRCUIT,LINEAR 1
M38510/10104BGA MICROCIRCUIT,LINEAR 3 EA NS Request Quotation JM38510/10104BGB MICROCIRCUIT,LINEAR 1
,LINEAR 10 EA NS Request Quotation LM108AH/883B MICROCIRCUIT,LINEAR 1 EA NS Request Quotation M38510/10104BGA
,LINEAR 31 EA NS Request Quotation LM108H/883C MICROCIRCUIT,LINEAR 18 EA NS Request Quotation M38510/10104BGA
M38510/10104BGA MICROCIRCUIT,LINEAR 32 EA NS Request Quotation JM38510/10104BGB MICROCIRCUIT,LINEAR 1
,LINEAR 20 EA NS Request Quotation LM108H/883C MICROCIRCUIT,LINEAR 18 EA NS Request Quotation M38510/10104BGA
LM108AH/883B MICROCIRCUIT,LINEAR 44 EA NS Request Quotation M38510/10104BGA MICROCIRCUIT,LINEAR 3 EA
M38510/10104BGA MICROCIRCUIT,LINEAR 35 EA NS Request Quotation LM108AH/883B MICROCIRCUIT,LINEAR 1 EA
Restrictions 5962-01-374-0034
5962-01-374-0034 is a Linear Microcircuit that does not have a nuclear hardened feature, but does have another critical feature or features such as tolerance, fit restriction or application. Demilitarization of this item has been confirmed and is not currently subject to changes. This item is a US Munitions List or Commerce Control List Item which must be destroyed to prevent restoration or repair. Only authorized parties may possess this item. This item is not suspected to be hazardous. This item does not contain a precious metal. This item is sensitive to Electrostatic Discharge.
Import and Export 5962-01-374-0034
- Schedule B
- Subscribe to View Schedule B
- HTS Code
- Subscribe to View HTS Code
End Users 5962-01-374-0034
- US Air Force (FXGX)
- Effective Date:
- 1 Aug 2006
- Former MOE Rule:
- FXTX
Approved Sources 5962-01-374-0034
- Part Number
- Manufacturer
- Status
- 364A3103P4
- Manufacturer
- 89954 - Bae Systems Controls Inc. (Active)
- Primary Buy
- Primary Buy
- NH636213-03
- 16236 - Dla Land And Maritime (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- M38510/10104BGA
- 27014 - National Semiconductor Corporation (Active)
- Incomplete Secondary Reference
- Incomplete Secondary Reference
- 364A3103P4
- 07690 - Bae Systems Controls Inc (Active)
- Secondary Buy
- Secondary Buy
- 364A3103PA
- 07690 - Bae Systems Controls Inc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
- 636213-03
- 07690 - Bae Systems Controls Inc (Active)
- Canceled/Obsolete
- Canceled/Obsolete
Datasheet 5962-01-374-0034
- Characteristic
- Specifications
- FIIG
- Specifications
- A458A0
- End Item Identification [AGAV]
- Flight Contro E/I Fscm 76823
- Case Outline Source And Designator [CTFT]
- A-1 Mil-M-38510
- Criticality Code Justification [CRTL]
- Feat
- Current Rating Per Characteristic [CTQX]
- -0.10 Milliamperes Collector Cutoff Current, Dc, With Specified Resistance Between Base And Emitter Microamperes And 10.00 Milliamperes Reverse Current, Dc Microamperes
- Departure From Cited Designator [ZZZX]
- Modified For ****Hcp****
- Design Function And Quantity [CSSL]
- 1 Amplifier, Operational, Linear
- Features Provided [CBBL]
- Externally Compensated And Radiation Hardened
- Operating Temp Range [AFGA]
- -55.0/+125.0 Deg Celsius
- Inclosure Configuration [CQSZ]
- Can
- Inclosure Material [CQSJ]
- Metal
- Input Circuit Pattern [CQZP]
- 2 Input
- Part Name Assigned By Controlling Agency [CXCY]
- Single Operational Amplifier
- Special Features [FEAT]
- Nuclear Hardness Critical Item
- Voltage Rating And Type Per Characteristic [CZEN]
- -20.0 Volts Minimum Absolute Input And 20.0 Volts Maximum Absolute Input
- Specification/Standard Data [ZZZK]
- 81349--38510/10104Bga Government Specification And 07690-636213-03 Manufacturers Source Control
- Storage Temp Range [AFJQ]
- -65.0/+150.0 Deg Celsius
- Terminal Surface Treatment [CWSG]
- Solder
- Terminal Type And Quantity [TTQY]
- 8 Printed Circuit
- Test Data Document [TEST]
- 81349-Mil-M-38510 Specification (Includes Engineering Type Bulletins, Brochures,Etc., That Reflect Specification Type Data In Specification Format; Excludes Commercial Catalogs, Industry Directories, And Similar Trade Publications, Reflecting General Type Data On Certain Environmental And Performance Requirements And Test Conditions That Are Shown As "Typical", "Average", "Nominal", Etc.). And 96906-Mil-Std-883 Standard (Includes Industry Or Association Standards, Individual Manufactureer Standards, Etc.).
Weapon Systems (WSDC) 5962-01-374-0034
DLA Procurement Analysis 5962-01-374-0034
Management Data 5962-01-374-0034
- Effective Date
- Organization
- Unit of Issue
- Unit Price
- Qty Unit Pack
- Unit of Issue
- Oct 2022
- Department of the Air Force (DF)
- EA
- Subscribe
- 1
- EA
- Oct 2021
- Department of the Air Force (DF)
- EA
- Subscribe
- 1
- EA
- Oct 2020
- Department of the Air Force (DF)
- EA
- Subscribe
- 1
- EA
- Mar 2020
- Defense Logistics Agency (DS)
- EA
- Subscribe
- 1
- EA
- Oct 2019
- Department of the Air Force (DF)
- EA
- Subscribe
- 1
- EA
- MOE
- USC
- Code
- Statement
- Order of Use
- Jump To Code
- Qty Per Assy
- UOM
- Technical Document
- Quantative Expression
- Code
- Department of the Air Force (DF)
- F
- R
- Refer To Gidep Alert
- GIDEP ALERT
- R
- Department of the Air Force (DF)
- F
- R
- Refer To Ah6-A-94-01A
- AH6-A-94-01A
- R
- Department of the Air Force (DF)
- F
- R
- Refer To Dsn 932-5364
- DSN 932-5364
- R
- Defense Logistics Agency (DS)
- I
- R
- Refer To Hci
- HCI
- R
Similar Supply Items to 5962-01-374-0034


















Freight Information 5962-01-374-0034
5962-01-374-0034 has freight characteristics.It has a National Motor Freight Classification (NMFC) of 061700. A Sub NMFC of Z. It has a NMFC Description of ELEC APPLIANCES/INSTRUMENTS NOI. 5962-01-374-0034 is rated as a variable freight class when transported by Less-Than Truckload (LTL) freight. It has a Uniform Freight Classification (UFC) number of 34580 which rates the freight between FCL and LCL. 5962-01-374-0034 has a variance between NMFC and UFC when transported by rail and the description should be consulted. It has a Water Commodity Code (WCC) of 72D for ocean manifesting and military sealift. 5962-01-374-0034 is classified as an Electrostatic Sensitive Device (ESD) when transported by water. 5962-01-374-0034 is not a consolidation and does not exceed 84" in any dimension. It should be compatible with a standard 72" Aircraft Cargo Door when transported by air.
Contracting Technical Data File (CTDF) 5962-01-374-0034 October 2021
Criticality and Quality
- Critical Item Code:
- Flight Safety:
- Life Support:
- Certified Samples:
- Serialization:
- First Article Test (FAT):
- Certificate of Quality Compliance:
- Production Lot Testing:
- Special Testing:
- Qualified Products List (QPL):
Commercial Properties
- Government Furnished Material:
- Government Furnished Tooling:
- Government Furnished Property:
- Price Evaluation Code:
- Diminshing Manufacturing Sources:
- Warranty:
- Commerical Off The Shelf (COTS):
- End Item Application:
- Auctioning Candidate:
- Source of Procurement:
- Contract Option:
Restrictions
- Boeing Rights Guard:
- Export Controlled:
- Controlled Technical Data Package (TDP):
- Restricted Technical Data Package (TDP):
- Contains Classified Material
- Weapons System Indicator Code (WSIC):
- K
Packaging Requirements
- Packaging Determination Table:
- Packaging Review Code:
- N
- Special Packaging Instruction Number (SPIN):
- Special Packaging Instruction Number Revision:
- Special Packaging Instruction Number Date:
- Pallet Reference Number Required: